• 제목/요약/키워드: Fume box

검색결과 11건 처리시간 0.021초

흄토치 성능 평가에 관한 연구 (Performance Assessment of Fume Extracting Welding Gun)

  • 최찬기;김태형;하현철;원정일
    • 한국산업보건학회지
    • /
    • 제9권2호
    • /
    • pp.90-99
    • /
    • 1999
  • Fume extracting welding gun is one of the promising options for reducing the welder's fume exposure. The performance of the gun was assessed on the basis of capture efficiency. Capture efficiencies were measured in a test chamber recommended by American Welding Society. The overall capture efficiency was turned out to be above 95%. But it did not include the effect of crossdraft existing in the real work environment because all experiments were conducted in a closed chamber. It thus needs more work in the future. In addition, the future directions for improving the pres ent commercial techniques of the gun were discussed.

  • PDF

플럭스 코어드 아크 용접 공정에서의 흄 형성량에 관한 연구 (A Study on Fume Formation Ratio on Flux Cored Arc Welding Process)

  • 윤충식;백남원
    • 한국환경보건학회지
    • /
    • 제25권3호
    • /
    • pp.108-112
    • /
    • 1999
  • A study was conducted for the effects of input energy on fume formation ratios based on electrode(FFR$_{electrode}(g/kg_{electrode})),\;deposited\;metal(FFR_{weld}(g/kg_{weld}))\;and\;slag(FFR_{slag}(g/kg_{slag}))\;at\;CO_2$ flux cored arc welding on stainless steel. Experiments were run in well designed welding fume box. Six types of flux cored wires were used and three levels of current and voltages were given. The measured values of $FFR_{electrode},\;FFR_{weld},\;FFR_{slag}\;are\;7.90{\pm}1.47\;g/kg_{electrode},\;9.18{\pm}1.65\;g/kg_{\electrode},\;71.8{\pm}24.2\;g/kg_{slag}$ respectively. Fume formation ratios are not increased dramatically by input energy because of simultaneous increasing of melted electrodes, deposited metal and slag. The results indicate that the test of fume formation ratios in the research on production of low fume welding wire can be run at the fixed condition of input energy rather than various condition.

  • PDF

Performance of self-compacting concrete at room and after elevated temperature incorporating Silica fume

  • Ahmad, Subhan;Umar, Arshad;Masood, Amjad;Nayeem, Mohammad
    • Advances in concrete construction
    • /
    • 제7권1호
    • /
    • pp.31-37
    • /
    • 2019
  • This paper evaluates the workability and hardened properties of self-compacting concrete (SCC) containing silica fume as the partial replacement of cement. SCC mixtures with 0, 2, 4, 6, 8 and 10% silica fume were tested for fresh and hardened properties. Slump flow with $T_{500}$ time, L-box and V-funnel tests were performed for evaluating the workability properties of SCC mixtures. Compressive strength, splitting tensile strength and modulus of rupture were performed on hardened SCC mixtures. Experiments revealed that replacement of cement by silica fume equal to and more than 4% reduced the slump flow diameter and increased the $T_{500}$ and V-funnel time linearly. Compressive strength, splitting tensile strength and modulus of rupture increased with increasing the replacement level of cement by silica fume and were found to be maximum for SCC mixture with 10% silica fume. Further, residual hardened properties of SCC mixture yielding maximum strengths (i.e., SCC with 10% silica fume) were determined experimentally after heating the concrete samples up to 200, 400, 600 and $800^{\circ}C$. Reductions in hardened properties up to $200^{\circ}C$ were found to be very close to normal vibrated concrete (NVC). For 400 and $600^{\circ}C$ reductions in hardened properties of SCC were found to be more than NVC of the same strength. Explosive spalling occurred in concrete specimens before reaching $800^{\circ}C$.

가연성 배기덕트-흄 화재위험성 평가에 관한 연구 (A Study on the Fire Risk Assessment of Combustible Exhaust Duct-fume)

  • 윤여송;이영순
    • 한국안전학회지
    • /
    • 제25권1호
    • /
    • pp.32-37
    • /
    • 2010
  • When back-out & firing Process applies heat, hume is piled up in exhaust duct by organic compound and it have high dangerousness. There by, the process is happening a lot of damage that is exhaust duct fire. However we do not have certain fire dangerousness estimation and digestion countermeasure. So we need preventive measure. Back-out & firing is a process which has fine structure, electrical and mechanical characteristics, such as firing kiln and back-out kiln which has pipe line and box type. The box oven is made of heating coil, fan motor and control panel. Back-out & firing process has air circulation institution of quick ventilation type. When we operate this process for long time, fire can break out easily. Duct is made by zinc shredder. If fire breaks out in duct inside, fire by deposit fume can be dispersed easily. Accordinglym, This project estimate danger for back-out & firing process exhaust duct through real fire test. And there is purpose of study to establish preventive measure.

Investigating the combination of natural and crushed gravel on the fresh and hardened properties of self-compacting concrete

  • Moosa Mazloom;Mohammad Ebrahim Charmsazi;Mohammad Hosein Parhizkari
    • Structural Monitoring and Maintenance
    • /
    • 제11권1호
    • /
    • pp.1-18
    • /
    • 2024
  • Self-compacting concrete is widely used around the globe today due to its special and unique properties. This study examines the effect of natural and crushed gravel combinations in different percentages in short-and long-term properties of concrete. The best utilized sand had a fineness modulus of 2.7. In the mentioned mix designs, silica fume was used with 0 and 7% of the weight of the cement. In order to check the properties of fresh and hardened concrete, 9 and 5 test types were performed, respectively. The carried out tests were slump flow, V-funnel, J-ring, L-box, U-box and column segregation for fresh concrete, and compressive, tensile and flexural strengths for hardened concrete. A mix with only 100% natural gravel was considered as the control mix. According to the results, the control mix design and the one containing 100% crushed gravel with silica fume were the best in fresh and hardened concrete tests, respectively. Finally, using the optimization method, a mix design with 25% natural gravel, 75% crushed gravel and silica fume was introduced as the best mix in terms of the results of both fresh and hardened concrete tests.

복합열화 환경을 받는 콘크리트 시설물을 위한 보수용 폴리머 시멘트 복합체의 내구성능 향상에 관한 연구 (Enhanced Durability Performance of Polymer Modified Cement Composites for Concrete Repair Under Combined Aging Conditions)

  • 원종필;박찬기
    • 한국농공학회논문집
    • /
    • 제47권6호
    • /
    • pp.27-34
    • /
    • 2005
  • The purpose of this study is to improve the durability performance of polymer modified cement composites for repair of concrete under combined aging conditions. The experimental procedure was divided into three parts. First, the replacement level of mineral admixtures in polymer modified cement composites were determined in an experimental study based on a Box Behnken design. Second, the flow value, compressive strength and chloride permeability test of sixteen types of mixtures were conducted. Test results show that the polymer modified cement composites were effected on the improvement of the compressive strength and permeability performance. Third, the effects on the replacement level of silica fume mixture was evaluated by the compressive strength, chloride permeability, chemical resistance and repeated freezing and thawing cycles test. They demonstrated that the polymer modified cement composites using mixture of silica fume, fly ash, and blast furnace slag improved the durability performance.

Effects of silica fume, superplasticizer dosage and type of superplasticizer on the properties of normal and self-compacting concrete

  • Mazloom, Moosa;Soltani, Abolfazl;Karamloo, Mohammad;Hassanloo, Ahmad;Ranjbar, Asadollah
    • Advances in materials Research
    • /
    • 제7권1호
    • /
    • pp.45-72
    • /
    • 2018
  • In the present study, a special attention has been paid to the effects regarding the use of different superplasticizers in different dosages. To do so, 36 mixes of normal and self-compacting concrete with two water/binder ratios of 0.35 and 0.45, four different types of superplasticizer including melamine-formaldehyde, naphthalene-formaldehyde, carboxylic-ether and poly-carboxylate, four different superplasticizer/cement ratios of 0.4%, 0.8%, 1.2% and 1.6% and two silica fume/cement ratios of 0% and 10% have been cast. Moreover, the initial and final setting time of the pastes have been tested. For self-compacting mixes, flow time, slump flow, V-funnel, J-ring and L-box tests have been carried out as well as testing the compressive strength and rupture modulus. For normal concrete mixes,slump test has been conducted to assess the workability of the mix and then for each mix, the compressive strength and rupture modulus have been determined. The results indicate that in addition to the important role of superplasticizer type and dosage on fresh state properties of concrete, these parameters as well as the use of silica fume could affect the hardened state properties of the mixes. For instance, the mixes whose superplasticizer were poly-carboxylic-ether based showed better compressive and tensile strength than other mixes. Besides, the air contents showed robust dependency to the type of the superplasticizer. However, the use of silica fume decreased the air contents of the mixes.

Mechanical, rheological, and durability analysis of self-consolidating concretes containing recycled aggregates

  • Hiwa Mollaei;Taleb Moradi Shaghaghi;Hasan Afshin;Reza Saleh Ahari;Seyed Saeed Mirrezaei
    • Structural Engineering and Mechanics
    • /
    • 제88권2호
    • /
    • pp.141-157
    • /
    • 2023
  • In the present paper, the effect of recycled aggregates on the rheological and mechanical properties of self-consolidating concrete is investigated experimentally and numerically. Hence, the specimen with two types of recycled aggregates, i.e., known and unknown resistance origins, are utilized for the studied specimens. The experiments in this study are designed using the Box-Behnken method, which is one of the response surface methods. Input variables in mixtures include silica fume in the range of 5-15% as a percentage substitute for cement weight and recycled coarse and fine aggregates in the range of 0-50% for both series of recycled materials as a substitute for natural materials. The studied responses are slump flow, V funnel, compressive strength, tensile strength, and durability. The results indicate that the increase in the amount of recycled aggregates reduces the rheological and mechanical properties of the mixtures, while silica fume effectively improves the mechanical properties. In addition, the results demonstrate that the fine recycled aggregates affect the total response of the concrete significantly. The results of tensile and compressive strengths indicate that the mixtures including 50% recycled materials with known resistance origin demonstrate better responses up to 8 and 10% compared to the materials with unknown resistance origins, respectively. Recycled materials with a specific resistance origin also show better results than recycled materials with an unknown resistance origin. Durability test results represent those concretes containing recycled coarse aggregates have lower strength compared to recycled fine aggregates. Also, a series of mathematical relationships for all the responses are presented using variance analysis to predict mixtures' rheological and mechanical properties.

통계적 방법에 의한 교면포장용 고성능 콘크리트의 최적배합비 도출 (Optimum Mix Design of High-Performance Concrete for Bridge Deck Overlay by Statistical Method)

  • 원종필;서정민;이창수;박해균;이명섭
    • 콘크리트학회논문집
    • /
    • 제17권4호
    • /
    • pp.559-567
    • /
    • 2005
  • 본 연구는 혼화재료(실리카퓸, 플라이애쉬, 고로슬래그)를 사용하여 교면 포장에 적용할 고성능 콘크리트의 최적배합비를 도출하기 위하여 실시되었다. 최적배합비를 도출하기 위하여 실리카퓸, 플라이애쉬, 고로슬래그의 세가지 혼화재료를 고려하여 통계학의 최적화 기법인 Box Behnken 설계 방법을 사용하였다. 압축강도와 염소이온투과저항성 시험을 실시하였으며 시험 결과를 기초로 최적의 배합비를 도출하였다. 도출된 최적배합은 기술적으로 분석하였으며 시험 결과는 교면포장을 위한 고성능 콘크리트 성능 기준과 비교하였다. 최적배합은 만족할 만한 성능을 보여주었다. 또한 최적배합으로 도출된 고성능 교면포장 콘크리트는 재료의 가격뿐만 아니라 모빌믹서를 사용하지 않고 일반 믹서를 사용하기 때문에 시공비용도 감소시킬 수 있다.

Ergonomic Evaluation of Some University Laboratories

  • Lee, Yun Keun;Lee, Ik Mo;Park, Jeongim;Yoon, Chung Sik;Rhie, Kwang Won;Park, Hee Sok
    • 대한인간공학회지
    • /
    • 제32권4호
    • /
    • pp.397-403
    • /
    • 2013
  • Objective: This article aims to report the results of ergonomic evaluation of some university laboratories. Background: Laboratory researchers are at risk for musculoskeletal injuries during routine laboratory procedures. However, little attention has paid to the working conditions of laboratory researchers, especially in Korea. Method: A checklist and questionnaire was developed and used to analyze the work conditions of 27 laboratories of chemistry, biology and pharmacy. Results: It was found that glove box, clean bench, and computer workstation are better than microscopy, and fume hood tasks, from ergonomic point of view. Conclusion: No domestic guideline is available for ergonomic intervention of laboratories. Further attention and studies are anticipated to improve the working conditions of laboratories.