• 제목/요약/키워드: Full-scale Static Test

검색결과 107건 처리시간 0.022초

Experimental and numerical investigation on flexural response of reinforced rubberized concrete beams using waste tire rubber

  • Memduh Karalar;Hakan Ozturk;Yasin Onuralp Ozkilic
    • Steel and Composite Structures
    • /
    • 제48권1호
    • /
    • pp.43-57
    • /
    • 2023
  • The impacts of waste tire rubber (WTR) on the bending conduct of reinforced concrete beams (RCBs) are investigated in visualization of experimental tests and 3D finite element model (FEM) using both ANSYS and SAP2000. Several WTR rates are used in total 4 various full scale RCBs to observe the impact of WTR rate on the rupture and bending conduct of RCBs. For this purpose, the volumetric ratios (Vf) of WTR were chosen to change to 0%, 2.5%, 5% and 7.5% in the whole concrete. In relation to experimental test consequences, bending and rupture behaviors of the RCBs are observed. The best performance among the beams was observed in the beams with 2.5% WTR. Furthermore, as stated by test consequences, it is noticed that while WTR rate in the RCBs is improved, max. bending in the RCBs rises. For test consequences, it is clearly recognized as WTR rate in the RCB mixture is improved from 0% to 2.5%, deformation value in the RCB remarkably rises from 3.89 cm to 7.69 cm. This consequence is markedly recognized that WTR rates have a favorable result on deformation values in the RCBs. Furthermore, experimental tests are compared to 3D FEM consequences via using ANSYS software. In the ANSYS, special element types are formed and nonlinear multilinear misses plasticity material model and bilinear misses plasticity material model are chosen for concrete and compression and tension elements. As a consequence, it is noticed that each WTR rates in the RCBs mixture have dissimilar bending and rupture impacts on the RCBs. Then, to observe the impacts of WTR rate on the constructions under near-fault ground motions, a reinforced-concrete building was modelled via using SAP2000 software using 3-D model of the construction to complete nonlinear static analysis. Beam, column, steel haunch elements are modeled as nonlinear frame elements. Consequently, the seismic impacts of WTR rate on the lateral motions of each floor are obviously investigated particularly. Considering reduction in weight of structure and capacity of the members with using waste tire rubber, 2.5% of WTR resulted in the best performance while the construction is subjected to near fault earthquakes. Moreover, it is noticeably recognized that WTR rate has opposing influences on the seismic displacement behavior of the RC constructions.

현장시험을 통한 개단말뚝의 폐색효과에 대한 연구 (Analysis of Plugging Effect for Open-ended Piles Based on Field Tests)

  • 고준영;정상섬
    • 한국지반공학회논문집
    • /
    • 제30권12호
    • /
    • pp.51-61
    • /
    • 2014
  • 연구에서는 사질토 지반에서 개단말뚝의 지지력에 영향을 미치는 폐색효과를 조사하기 위하여 현장재하시험을 수행하였다. 현장재하시험은 직경이 다른 총 3본의 시험말뚝(508.0, 711.2, 914.4mm)을 제작하여 각각 동재하시험과 정재하시험을 실시하였다. 내주면마찰력과 외주면마찰력을 분리 측정하기 위하여 시험말뚝을 이중관으로 제작하였고, 외부말뚝의 안쪽과 내부말뚝의 바깥쪽 표면에 변형률계를 부착하였다. 정재하시험 결과, 내주면마찰력은 선단부로부터 총 관내토 길이의 약 18-34%의 부근에서 집중적으로 발생하였고, 이를 통해 말뚝 선단부근의 관내토가 내주면마찰력 발현에 큰 영향을 미치는 것을 알 수 있었다. 또한, 말뚝직경이 클수록 전체지지력에 대한 내주면마찰력과 순단면적의 선단지지력의 합의 비가 감소하는 것으로 나타났다. 그리고 말뚝의 폐색율을 정량화하기 위해 시험말뚝의 incremental filling ratio(IFR)를 측정하여 분석한 결과, SPT의 N값과 상관관계가 있는 것으로 나타났다.

Comparative study on the performance of Pod type waterjet by experiment and computation

  • Kim, Moon-Chan;Park, Warn-Gyu;Chun, Ho-Hwan;Jung, Un-Hwa
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제2권1호
    • /
    • pp.1-13
    • /
    • 2010
  • A comparative study between a computation and an experiment has been conducted to predict the performance of a Pod type waterjet for cm amphibious wheeled vehicle. The Pod type waterjet has been chosen on the basis of the required specific speed of more than 2500. As the Pod type waterjet is an extreme type of axial flow type waterjet, theoretical as well as experimental works about Pod type waterjets are very rare. The main purpose of the present study is to validate and compare to the experimental results of the Pod type waterjet with the developed CFD in-house code based on the RANS equations. The developed code has been validated by comparing with the experimental results of the well-known turbine problem. The validation also extended to the flush type waterjet where the pressures along the duct surface and also velocities at nozzle area have been compared with experimental results. The Pod type waterjet has been designed and the performance of the designed waterjet system including duct, impeller and stator was analyzed by the previously mentioned m-house CFD Code. The pressure distributions and limiting streamlines on the blade surfaces were computed to confirm the performance of the designed waterjets. In addition, the torque and momentum were computed to find the entire efficiency and these were compared with the model test results. Measurements were taken of the flow rate at the nozzle exit, static pressure at the various sections along the duct and also the nozzle, revolution of the impeller, torque, thrust and towing forces at various advance speed's for the prediction of performance as well as for comparison with the computations. Based on these measurements, the performance was analyzed according to the ITTC96 standard analysis method. The full-scale effective and the delivered power of the wheeled vehicle were estimated for the prediction of the service speed. This paper emphasizes the confirmation of the ITTC96 analysis method and the developed analysis code for the design and analysis of the Pod type waterjet system.

Geotechnical Engineering Progress with the Incheon Bridge Project

  • Cho, Sung-Min
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.133-144
    • /
    • 2009
  • Incheon Bridge, 18.4 km long sea-crossing bridge, will be opened to the traffic in October 2009 and this will be the new landmark of the gearing up north-east Asia as well as the largest & longest bridge of Korea. Incheon Bridge is the integrated set of several special featured bridges including a magnificent cable-stayed girder bridge which has a main span of 800 m width to cross the navigation channel in and out of the Port of Incheon. Incheon Bridge is making an epoch of long-span bridge designs thanks to the fully application of the AASHTO LRFD (load & resistance factor design) to both the superstructures and the substructures. A state-of-the-art of the geotechnologies which were applied to the Incheon Bridge construction project is introduced. The most Large-diameter drilled shafts were penetrated into the bedrock to support the colossal superstructures. The bearing capacity and deformational characteristics of the foundations were verified through the world's largest static pile load test. 8 full-scale pilot piles were tested in both offshore site and onshore area prior to the commencement of constructions. Compressible load beyond 30,000 tonf pressed a single 3 m diameter foundation pile by means of bi-directional loading method including the Osterberg cell techniques. Detailed site investigation to characterize the subsurface properties had been carried out. Geotextile tubes, tied sheet pile walls, and trestles were utilized to overcome the very large tidal difference between ebb and flow at the foreshore site. 44 circular-cell type dolphins surround the piers near the navigation channel to protect the bridge against the collision with aberrant vessels. Each dolphin structure consists of the flat sheet piled wall and infilled aggregates to absorb the collision impact. Geo-centrifugal tests were performed to evaluate the behavior of the dolphin in the seabed and to verify the numerical model for the design. Rip-rap embankments on the seabed are expected to prevent the scouring of the foundation. Prefabricated vertical drains, sand compaction piles, deep cement mixings, horizontal natural-fiber drains, and other subsidiary methods were used to improve the soft ground for the site of abutments, toll plazas, and access roads. Light-weight backfill using EPS blocks helps to reduce the earth pressure behind the abutment on the soft ground. Some kinds of reinforced earth like as MSE using geosynthetics were utilized for the ring wall of the abutment. Soil steel bridges made of corrugated steel plates and engineered backfills were constructed for the open-cut tunnel and the culvert. Diverse experiences of advanced designs and constructions from the Incheon Bridge project have been propagated by relevant engineers and it is strongly expected that significant achievements in geotechnical engineering through this project will contribute to the national development of the longspan bridge technologies remarkably.

  • PDF

브라켓 및 WUF-B 형식 철골모멘트골조 약축접합부 내진성능평가 (Cyclic Testing of Bracket and WUF-B Type Weak-Axis Steel Moment Connections)

  • 이강민;정희택;윤석용;이은모;오경환
    • 한국강구조학회 논문집
    • /
    • 제20권4호
    • /
    • pp.483-491
    • /
    • 2008
  • 1994년 노스리지 지진 이후, 철골모멘트골조 강축방향 접합부의 내진성능 평가에 관한 연구가 국내 외에서 활발하게 진행되어온 반면, 국내 철골모멘트골조 내진설계 및 시공의 실무에 관행적으로 적용되고 있는 철골모멘트골조 약축방향 접합부의 내진성능 평가 연구가 국내는 물론 국외에서도 그 사례를 찾아보기 힘든 상황이다. 따라서 본 연구에서는 국내에서 내진성능 확보 여부가 확인되지 않은 상태에서 내진설계 실무에서 가장 많이 사용되고 있는 브라켓 형식 및 WUF-B 형식의 접합상세를 갖는 철골모멘트골조 약축접합부의 실물대(Full scale) 실험체를 제작 및 실험하여 이와 같은 형상의 접합부에 대한 내진성능을 평가하여 향후 이와 같은 형상을 갖는 철골모멘트골조 약축접합부의 설계를 위한 기초자료를 제공하는 것을 목적으로 한다. 이러한 목적을 달성하기 위하여, 현장조사 및 설계도서등의 기존 자료를 통해 총 2개의 실험체를 제작하여 내진성능을 평가 실험연구를 수행하였다. 실험결과로부터 최대내력 비교, 하중-변위 이력 및 응력도 등에 대한 거동을 비교 분석 하였다. 실험결과 층간변위각 5%의 BR-W 실험체가 층간변위각 4%를 갖는 WUF-B 실험체에 비해 우수한 구조적 거동을 보여주었으며, 설계 내력을 상회하는 내력을 보유하고 있는 것을 알 수 있었다. 또한 브라켓 형식의 실험체는 최대내력 도달 이후 완만한 강도 저하를 나타내었으나, WUF-B 형식의 실험체는 최대내력 도달 이후 급격한 하중 저하를 나타내며 취성적인 거동을 보였다.

파이프 이음부가 단동온실 구조성능에 미치는 영향: 실대형 실험적 및 해석적 연구 (Effect of the Pipe Joint on Structural Performance of a Single-span Greenhouse: A Full-scale Experimental and Numerical Study)

  • 신현호;류희룡;유인호;조명환;서태철;김승유;최만권
    • 생물환경조절학회지
    • /
    • 제30권4호
    • /
    • pp.410-418
    • /
    • 2021
  • 본 연구에서는 원예특작시설 내재해형 규격서에 등록되어 있는 폭이 넓은 단동온실(10-단동-5형)을 대상으로 기초의 경계조건과 서까래 강관의 이음 유무에 대해 실물 크기 실험을 실시하고 그 결과를 수치해석 결과와 비교하여 이음부가 있을 때 구조성능 차이에 대해 알아보았다. 각 측정 위치별 변위를 실험에서 측정한 값과 수치해석으로 예측한 값을 비교한 결과에서는 기초의 조건 및 서까래 강관 이음 유무에 상관없이 모두 상당한 차이를 보였고, 힌지 조건 보다 고정 조건이 상대적으로 차이가 컸다. 그리고 모든 절점을 강접합으로 가정하고 구조해석한 결과를 구조실험과 비교한 결과에서는 힌지조건이 고정조건 보다 잘 일치하였지만 해석값이 실험값 보다 크게 나타났다. 수치해석은 모든 절점을 강접합으로 가정했기 때문에 실제 성능과 달랐다. 따라서 현재 모든 절점을 강접합으로 가정하고 온실을 설계를 하면 과소설계될 우려가 있어 앞으로 신뢰성 높은 온실 설계를 위해서는 서까래와 도리가 교차하는 교차부 성능 특성을 고려한 구조해석 기술 개발이 이루어져야 할 것으로 판단된다.

높은 아치형 지중강판 구조물의 시공 중 거동 분석 (Behaviors of the High-profile Arch Soil-steel Structure During Construction)

  • 이종구;조성민;김경석;김명모
    • 한국지반공학회논문집
    • /
    • 제19권6호
    • /
    • pp.71-84
    • /
    • 2003
  • 지중강판 구조물은 강판부재 내에 발생하는 휨모멘트에는 매우 취약하기 때문에 그 주변을 양질의 흙으로 뒷채움하여 주변 흙과의 상호작용에 의하여 상부에 작용하는 하중을 지지한다. 그러나, 구조물 측면을 뒷채움할 때나 최소토피고를 확보하지 못한 상태에서 활하중이 작용할 때에는 강판부재내에 과도한 모멘트가 발생할 수 있다. 현재 설계기준에서는 허용변형량을 제시하여 시공 중에 과도한 변형이 발생하는 것을 방지하고 있으며 Duncan(1979)과 McGrath 등(2001)은 강도해석법을 제안하여 시공 중에 발생하는 모멘트를 강판의 소성강도 이내로 제한하고 있지만, 허용변형량은 경험적으로 규정한 값이고 강도해석에 의한 구조 안정성 검토는 유한요소 해석결과를 바탕으로 제안되었기 때문에 이들에 대하여 실험적 검증이 필요하다. 이 연구에서는 높은 아치형 구조물에 대한 실규모 현장시험을 실시하여 시공 중 거동과 활하중에 대한 하중지지 거동을 분석하였다. 시험결과를 바탕으로 시험시공 구조물의 허용변형량을 '높이의 1.45%' 로 추정할 수 있었는데 이는 설계기준의 허용값인 '높이의 2%' 보다 작은 값이었다. 또한, 계측결과를 Duncan과 McGrath 등이 제안한 강도해석결과와 비교하여 Duncan은 성토하중에 의한 모멘트는 과소평가하고 활하중 모멘트는 과대평가 하지만 McGrath 등은 두 값을 모두 실제와 근접하게 예측함을 알 수 있었다. 그러나, 두 방법에 의한 소성힌지에 대한 안전율은 실제 안전율과 잘 일치하여 두 방법 모두 시공 중에 작용하는 활하중에 대한 구조 안정성을 적절히 평가할 수 있음을 확인하였다.나 길항력(6.4 ㎜)은 남아있었다. 또한 분자량 10kDa 이하의 분획에서는 chitinase 활성은 없으나 길항력(5.2㎜)은 나타내었고, 80℃에서 열처리하여도 길항력(5.0mm)이 남아있어 효소 이외 다른 생리활성물질이 존재함을 확인하였다.rin, (+)-taxifolin 3-O--$\beta$-D-glucopyranoside, (+)-catechin 및 benzoic acid의 함량은 건조 및 처리 온도가 증가할 수록 감소하는 양상을 나타내었다.tier taste and the Doenjang with P. japonica Powder had the least sweet taste. In the flavor and overall Preference, the Doenjang with P. japonica powder was the lowestEX>로 측정되었고, 계사내 지붕의 표면 온도는 최고 $29^{\circ}C$가 측정되었다. 계사 내 표면 온도 및 닭의 표면 온도는 계사내 공기온도의 영향을 많이 받는 것으로 나타났다.ill in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times