• 제목/요약/키워드: Full-scale Field Test

검색결과 132건 처리시간 0.025초

Real-scale field testing for the applicability examination of an improved modular underground arch culvert with vertical walls

  • Tae-Yun Kwon;Jin-Hee Ahn;Hong-duk Moon;Kwang-Il Cho;Jungwon Huh
    • Advances in concrete construction
    • /
    • 제15권6호
    • /
    • pp.377-389
    • /
    • 2023
  • In this study, an improved modular arch system with the lower arch space composed of a precast arch block and an outrigger was proposed as an underground culvert, and its applicability and structural behaviors were confirmed. This modular arch culvert structure with vertical walls was designed using precast blocks and by adjusting the placement spacing of concrete blocks to the upper part form an arch shape and the lower part form a vertical wall shape, based on previously researched modular arch systems. Owing to the vertical wall of the proposed modular arch system, it is possible to secure a load-carrying capacity and an arch space that can sufficiently resist the earth pressure generated from the backfill soil and loading on the arch system. To verify the structural characteristics, and applicability of the proposed modular precast arch culvert structure, a full-scale modular culvert specimen was fabricated, and a loading test was conducted. By examining its construction process and loading test results, the applicability and constructability of the proposed structure were analyzed along with its structural characteristics. In addition, its the structural predictability and safety for the applicability were evaluated by comparing the construction process and loading test results with the FE analysis results.

Design of tall residential buildings in Singapore for wind effects

  • Balendra, T.;Ma, Z.;Tan, C.L.
    • Wind and Structures
    • /
    • 제6권3호
    • /
    • pp.221-248
    • /
    • 2003
  • The design of high-rise building is often influenced by wind-induced motions such as accelerations and lateral deflections. Consequently, the building's structural stiffness and dynamic (vibration periods and damping) properties become important parameters in the determination of such motions. The approximate methods and empirical expressions used to quantify these parameters at the design phase tend to yield values significantly different from each other. In view of this, there is a need to examine how actual buildings in the field respond to dynamic wind loading in order to ascertain a more realistic model for the dynamic behavior of buildings. This paper describes the findings from full-scale measurements of the wind-induced response of typical high-rise buildings in Singapore, and recommends an empirical forecast model for periods of vibration of typical buildings in Singapore, an appropriate computer model for determining the periods of vibration, and appropriate expressions which relate the wind speed to accelerations in buildings based on wind tunnel force balance model test and field results.

삼성 초전도 시험설비의 외부자장 발생용 자석의 자기장 해석 (magnetic Field Analysis of Background Magnet in SSTF(Samsung Superconducting Test Facility))

  • 김상보;;윤천석;방성근;박현기;김기만
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.147-149
    • /
    • 2000
  • Samsung Superconducting Test Facility (SSTF) will be built at SAIT, Taejeon. The superconducting cables to be used for KSTAR magnets are going to be tested in SSTF. The background magnet in SSTF is needed to simulate harsh magnetic environment for testing short CICC samples as well as full-scale magnets. The main coils can make central magnetic field of up to 8 Tesla and the blip coils can maintain fast ramping rate of 20T/s. The cancellation coils reduce the disturbance of main coils due to blip coils. The magnetic field distribution of these coils has been obtained with finite element method as well as the direct integration method.

  • PDF

거가대교 케이슨기초 그라우트 충전 사례연구 (A Case Study on Caisson Foundation Grouting in Geo-Ga Bridge)

  • 배경태;차경섭;김영진;박충환;정경환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1046-1050
    • /
    • 2010
  • During construction of a sea-crossing bridge grouting was used to fill densely the space between the bottom of caisson and the ground. This grout mixture was mixed with an anti-washout admixture after locating accurately the pre-cast caisson on three concrete landing pads. This method differs significantly from the costly conventional method, for bridge foundations offshore, where concrete is placed in situ after excavating inside of a temporary concrete coffering wall. To verify the grouting method in advance, the full-scale field tests were performed twice on land. After identifying the fluidity of the grout material to be filled, finding some possible problems with the main construction and revising the original design, the main construction has been continuing successfully with 20 caissons completed to date. The purpose of this paper is to introduce for the first time in Korea the grouting method including the automatic and the manual monitoring system based on the main construction of the caisson foundation.

  • PDF

성토지지말뚝에 의한 아칭효과 연구 (A Study on the Arching Effect due to Embankment Piles)

  • 이승현
    • 한국산학기술학회논문지
    • /
    • 제18권7호
    • /
    • pp.375-381
    • /
    • 2017
  • 성토지지말뚝의 아칭효과를 실험적으로 살펴보고자 현장시험을 수행하였으며 계측결과로부터 구한 아칭효율을 이론식에 의한 값과 비교해 보았다. 성토지지말뚝의 아칭효과를 살펴보기 위해 측정한 하중계 및 토압계에 의한 계측값들은 대체적으로 성토지지말뚝의 아칭효과를 반영하였다. 하중계 측정값을 통해 볼 때 아칭효율은 성토고 3m 까지는 평면변형률 조건을 가정한 이론식에 의한 값보다 작았으나 4m 이상에서는 이론식에 의한 값보다 큰 값을 보였으며 이론식에 의할 경우, 아칭효율은 성토고에 따라 감소하는 경향을 보였으나 측정결과는 성토고에 따라 아칭효율도 증가하는 경향을 나타내었다. 현장 시험에서 계획했던 최종 성토고까지 비교적 원활하게 작동하였던 토압계에 의한 계측결과에 따르면, 성토고에 따라 평면변형률 조건을 가정한 이론식에 의한 값보다 큰 아칭효율을 나타내었으며 4m 이상의 성토고에 대해서는 아칭효율의 변화양상 또한 이론식과 유사한 경향을 보였다. 토압계 측정결과에 따르면 성토고 2m, 3m, 4m, 5m 그리고 6m일 때의 아칭효율은 평면변형률조건을 가정한 이론식에 의한 아칭효율에 비해 각각 1.05배, 1.23배, 1,29배, 1.28배 그리고 1.29배 큰 값들을 보여 우수한 아칭효과를 보임을 알 수 있었다. 현장시험을 통해 얻은 하중계 및 토압계 측정값들로부터 계산된 아칭효율은 말뚝을 격자배치한 경우에 대한 이론식에 의한 그것보다 상당히 컸다.

향상된 슈도-헤시안 행렬을 이용한 탄성파 완전 파형역산 (Frequency domain elastic full waveform inversion using the new pseudo-Hessian matrix: elastic Marmousi-2 synthetic test)

  • 최윤석;신창수;민동주
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.329-336
    • /
    • 2007
  • For scaling of the gradient of misfit function, we develop a new pseudo-Hessian matrix constructed by combining amplitude field and pseudo-Hessian matrix. Since pseudo- Hessian matrix neglects the calculation of the zero-lag auto-correlation of impulse responses in the approximate Hessian matrix, the pseudo-Hessian matrix has a limitation to scale the gradient of misfit function compared to the approximate Hessian matrix. To validate the new pseudo- Hessian matrix, we perform frequency-domain elastic full waveform inversion using this Hessian matrix. By synthetic experiments, we show that the new pseudo-Hessian matrix can give better convergence to the true model than the old one does. Furthermore, since the amplitude fields are intrinsically obtained in forward modeling procedure, we do not have to pay any extra cost to compute the new pseudo-Hessian. We think that the new pseudo-Hessian matrix can be used as an alternative of the approximate Hessian matrix of the Gauss-Newton method.

  • PDF

Model and Field Testing of a Heavy-Duty Gas Turbine Combustor

  • Ahn, Kook-Young;Kim, Han-Seok;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • 제15권9호
    • /
    • pp.1319-1327
    • /
    • 2001
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed 1:1 scale. The model experiments were executed at a lower pressure than that in a real gas turbine. Combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure and NOx emission were measured at partial and full loads for both model and on-site testing. The comparison of these items in the stand and field test results led to has the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

Verifying ASCE 41 the evaluation model via field tests of masonry infilled RC frames with openings

  • Huang, Chun-Ting;Chiou, Tsung-Chih;Chung, Lap-Loi;Hwang, Shyh-Jiann;Jaung, Wen-Ching
    • Earthquakes and Structures
    • /
    • 제19권3호
    • /
    • pp.157-174
    • /
    • 2020
  • The in-situ pushover test differs from the shake-table test because it is performed outdoors and thus its size is not restricted by space, which allows us to test a full-size building. However, to build a new full-size building for the test is not economical, consequently scholars around the world usually make scale structures or full-scale component units to be tested in the laboratory. However, if in-situ pushover tests can be performed on full-size structures, then the seismic behaviors of buildings during earthquakes can be grasped. In view of this, this study conducts two in-situ pushover tests of reinforced concrete (RC) buildings. One is a masonry-infilled RC building with openings (the openings ratio of masonry infill wall is between 24% and 51%) and the other is an RC building without masonry infill. These two in-situ pushover tests adopt obsolescent RC buildings, which will be demolished, to conduct experiment and successfully obtain seismic capacity curves of the buildings. The test results are available for the development or verification of a seismic evaluation model. This paper uses ASCE 41-17 as the main evaluation model and is accompanied by a simplified pushover analysis, which can predict the seismic capacity curves of low-rise buildings in Taiwan. The predicted maximum base shear values for masonry-infilled RC buildings with openings and for RC buildings without masonry infill are, respectively, 69.69% and 87.33% of the test values. The predicted initial stiffness values are 41.04% and 100.49% of the test values, respectively. It can be seen that the ASCE 41-17 evaluation model is reasonable for the RC building without masonry infill walls. In contrast, the analysis result for the masonry infilled RC building with openings is more conservative than the test value because the ASCE 41-17 evaluation model is limited to masonry infill walls with an openings ratio not exceeding 40%. This study suggests using ASCE 41-17's unreinforced masonry wall evaluation model to simulate a masonry infill wall with an openings ratio greater than 40%. After correction, the predicted maximum base shear values of the masonry infilled RC building with openings is 82.60% of the test values and the predicted initial stiffness value is 67.13% of the test value. Therefore, the proposed method in this study can predict the seismic behavior of a masonry infilled RC frame with large openings.

폴리머 절연물 소재의 전기적 밀 복합열화 특성평가 기술 (Evaluation Technology of Electrical and reliableility Characteristics for Outdoor Polymer Insulator Materials)

  • 안명상;박효열;나문경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1343-1344
    • /
    • 2006
  • There have been numerous accelerated aging laboratory tests for evaluating suitability of polymeric materials and devices. Aging test for materials and its full scale device has been conducted. Service experience plays a key role in the utility section of composite insulators. A meaningful and reliable accelerated aging test is needed for evaluating composite insulator. During the service these insulators are subjected to aging stress such as humidity, pollution, and electrical field, and erosion and tracking of the weathershed occurs. This paper presents the criteria of reliability evaluation and evaluation facilities for 22.9 kV suspension composite insulator. We adopt the criteria of reliability evaluation consist of two test methods. One is CEA tracking wheel test for examining the tracking and erosion performance of composite insulator. The other is multi-stress aging test for examining effects of environmental factors such as UV, temperature, humidity, etc on composite insulator.

  • PDF

유효 스터럽 개념을 이용한 전단보강근의 강도 예측 (Predicting Actual Strength of Shear Reinforcement Using Effective Stirrup Concept)

  • 권기연;양준모;이주하;윤영수
    • 콘크리트학회논문집
    • /
    • 제20권1호
    • /
    • pp.99-107
    • /
    • 2008
  • 본 논문에서는 유효 스터럽 개념을 이용한 전단보강근의 강도 예측 방법을 제안하고 있다. 유효 스터럽 개념을 이용한 예측에서 가장 중요시 되는 부분인 전단 균열각 예측은 수정압축장이론 (modified compression field theory, MCFT)을 이용하여 수행하였다. 현 설계기준인 ACI 318-05와 기존 문헌에서 인용한 39개의 실제 실험 데이터를 이용하여 예측 방법의 유효성을 평가하였다. 평가시 고려한 영향인자로는 콘크리트 강도 그리고 전단보강근의 종류가 있었고, 추가로 2개의 full-scale의 보 실험을 수행하여 제안된 방법의 헤디드 바 사용 시험체의 확대 적용 가능성도 평가하였다.