• Title/Summary/Keyword: Full Specimen

Search Result 311, Processing Time 0.022 seconds

Computational assessment of blockage and wind simulator proximity effects for a new full-scale testing facility

  • Bitsuamlak, Girma T.;Dagnew, Agerneh;Chowdhury, Arindam Gan
    • Wind and Structures
    • /
    • v.13 no.1
    • /
    • pp.21-36
    • /
    • 2010
  • A new full scale testing apparatus generically named the Wall of Wind (WoW) has been built by the researchers at the International Hurricane Research Center (IHRC) at Florida International University (FIU). WoW is capable of testing single story building models subjected up to category 3 hurricane wind speeds. Depending on the relative model and WoW wind field sizes, testing may entail blockage issues. In addition, the proximity of the test building to the wind simulator may also affect the aerodynamic data. This study focuses on the Computational Fluid Dynamics (CFD) assessment of the effects on the quality of the aerodynamic data of (i) blockage due to model buildings of various sizes and (ii) wind simulator proximity for various distances between the wind simulator and the test building. The test buildings were assumed to have simple parallelepiped shapes. The computer simulations were performed under both finite WoW wind-field conditions and in an extended Atmospheric Boundary Layer (ABL) wind flow. Mean pressure coefficients for the roof and the windward and leeward walls served as measures of the blockage and wind simulator proximity effects. The study uses the commercial software FLUENT with Reynolds Averaged Navier Stokes equations and a Renormalization Group (RNG) k-${\varepsilon}$ turbulence model. The results indicated that for larger size test specimens (i.e. for cases where the height of test specimen is larger than one third of the wind field height) blockage correction may become necessary. The test specimen should also be placed at a distance greater than twice the height of the test specimen from the fans to reduce proximity effect.

Full-Scale Test on Precast Concrete Arch Bridge with Reinforced Joint and Backfill (보강된 이음부와 뒤채움을 적용한 조립식 프리캐스트 콘크리트 아치교량의 실물모형실험)

  • Chung, Chulhun;Joo, Sanghoon;Choi, Dongchan;Lee, Jongyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.389-402
    • /
    • 2014
  • In this paper, the load test of full-scale precast concrete arch bridges considering reinforced joint and backfill was conducted. It is an improved method that the reinforced joint enhanced the structural performance of conventional masonry arch system which was proposed by previous researchers. The models of full-scale test are $10m(span){\times}3m$ (rise) and $10m(span){\times}2m$ (rise), which are 2 meters in width. The critical load position was shown at a third-span from the results of the pre-analysis. Based on the this results, the positions of load, measuring items and points were determined in experiments. As a result, the maximum load capacity of the specimen $10m{\times}2m$, a relatively small rise to span ratio (compared to the specimen $10m{\times}3m$), was higher than the specimen $10m{\times}3m$. It was evaluated that all the specimens have sufficient structural performance on the design load.

The Effect of Specimen Size in Charpy Impact Testing (샬피 충격시험에 있어서 시험편 크기의 영향)

  • Kim, Hoon;Kim, Joo-Hark;Chi, Se-Hwan;Hong, Jun-Hwa
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.1
    • /
    • pp.93-103
    • /
    • 1997
  • Charpy V-notch impact tests were performed on the full-, half-and third-size specimens from two ferritic SA 508 Cl. 3 steels for nuclear pressure vessel. New normalization factors were proposed to predict the upper shelf energy(USE) and the ductile-brittle transition temperature(DBTT) of full-size specimens from the measured data on sub-size specimens. The factors for the USE and the DBTT are $(Bb^2/Kt); and; (Bb/R)^1/2/, $ respectively, where B the width, b the ligament size, $K_{t}$ the elastic stress concentration factor, and R the notch root radius. These correlations successfully estimated the USE and DBTT of the full-size specimens based on sub-size specimen data. In addition, the size effects were studied to develop the correlations among absorbed energy, lateral expansion(LE) and displacement. It was also found that the LE was able to be estimated from the displacement obtained by the instrumented impact test, and that the displacement would be used as a criterion for the toughness of the steels corresponding to change in their yield strength.h.

Laboratory Performance Evaluation of Alternative Dowel Bar for Jointed Concrete Pavements (콘크리트 포장용 고내구성 대체 다웰바의 실내공용성 평가)

  • Park, Seong Tae;Park, Jun Young;Lee, Jae Hoon;Kim, Hyung Bae
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • PURPOSES: The problem under this circumstance is that the erosion not only drops strength of the steel dowel bar but also comes with volume expansion of the steel dowel bar which can reduce load transferring efficiency of the steel dowel bar. To avoid this erosion problem, alternative dowers bars are developed. METHODS: In this study, the bearing stresses between the FRP tube dowel bar and concrete slab are calculated and compared with its allowable bearing stress to check its structural stability in the concrete pavement. These comparisons are conducted with several cross-sections of FRP tube dowel bars. Comprehensive laboratory tests including the shear load-deflection test on a full-scale specimen and the full-scale accelerated joint concrete pavement test are conducted and the results were compared with those from the steel dowel bar. RESULTS: In all cross-sections of FRP tube dowel bars, computed bearing stresses between the FRP tube dowel bar and concrete slab are less than their allowable stress levels. The pultrusion FRP-tube dowel bar show better performance on direct shear tests on full-scale specimen and static compression tests at full-scale concrete pavement joints than prepreg and filament-winding FRP-tube dowel bar. CONCLUSIONS: The FRP tube dowel bars as alternative dowel bar are invulnerable to erosion that may be caused by moisture from masonry joint or bottom of the pavement system. Also, the pultrusion FRP-tube dowel bar performed very well on the laboratory evaluation.

A Study of Statistic Behavior of Segmental U-shaped Prestressed Concrete Girder Applied with Integrated Tensioning Systems (복합긴장방식이 적용된 세그멘탈 U형 거더 정적 거동 연구)

  • Hyunock Jang;Ilyoung Jang
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.329-338
    • /
    • 2024
  • Purpose: This study verified the safety of the improved box-type girder behavior by comparing and evaluating the bending behavior results of a full-scale specimen based on the analytical behavior of the splice element PSC U-shaped girder with integrated tensioning systems. Method: Based on the results of the service and strength limit state design using the bridge design standard(limit state design method), the applied load of a 40m full-scale specimen was calculated and a static loading experiment using the four-point loading method was performed. Result: When the design load, crack load, and ultimate load were applied, the specimen deflection occurred at 97.1%, 98.5%, and 79.0% of the analytical deflection value. When the design load, crack load, and ultimate load were applied, the crack gauge was measured at 0.009~0.035mm, 0.014~0.050mm, and 6.383~5.522mm at each connection. Conclusion: The specimen behaved linear-elastically until the crack load was applied, and after cracks occurred, it showed strainhardening up to the ultimate load, and it was confirmed that the resistance of bending behavior was clearly displayed against the applied load. The cracks in the dry joints were less than 25% of grade B based on the evaluation of facility condition standard. The final residual deformation after removing the ultimate load was 0.114mm, confirming the stable behavior of the segment connection.

Resonant Fatigue Testing of Full-Scale Composite Helicopter Blades (공진현상을 이용한 실물 복합재 헬리콥터 블레이드의 피로수명 평가)

  • Kee, Young-Jung;Kim, Tae-Joo;Kim, Seung-Ho
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.1-7
    • /
    • 2010
  • Fatigue properties of composite materials are extremely important to design durable and reliable helicopter rotor blades. However, it is very difficult to apply conventional fatigue test loads in short period. Therefore, accelerating test speed and facilitating spectrum load realization are required. In this study, we have developed a fatigue testing method that uses a resonance of simply supported beam type blade specimen. This test consists in exciting the blade specimen with a frequency that corresponds to its natural frequency. In that case, the test specimen similar to a beam fixed between two pivot points starts vibrating and is significantly deformed. Resonant fatigue tests were performed by changing exciting vertical amplitude and frequency, and S-N curves of each composite materials were successfully obtained.

Dynamic Fracture Properties of Modified S-FPZ Model for Concrete

  • Yon, Jung-Heum;Seo, Min-Kuk
    • International Journal of Concrete Structures and Materials
    • /
    • v.19 no.1E
    • /
    • pp.25-32
    • /
    • 2007
  • The fracture energy evaluated from the previous experimental results can be simulated by using the modified singular fracture process zone (S-FPZ) model. The fracture model has two fracture properties of strain energy release rate for crack extension and crack close stress versus crack width relationship $f_{ccs}(w)$ for fracture process zone (FPZ) development. The $f_{ccs}(w)$ relationship is not sensitive to specimen geometry and crack velocity. The fracture energy rate in the FPZ increases linearly with crack extension until the FPZ is fully developed. The fracture criterion of the strain energy release rate depends on specimen geometry and crack velocity as a function of crack extension. The behaviors of micro-cracking, micro-crack localization and full development of the FPZ in concrete can be explained theoretically with the variation of strain energy release rate with crack extension.

Development of a Micro Tensile Tester for the Material Characterization and the Reliability Estimation of Micro Components (마이크로 부품의 물성 및 신뢰성 평가를 위한 시험기 개발)

  • 이낙규;최석우;임성주;최태훈;이형욱;나경환
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.2
    • /
    • pp.27-33
    • /
    • 2004
  • This paper is concerned with development of a micro tensile testing machine for optical functional materials such as single or poly crystal silicon and nickel film. Two micro tensile testers have been developed for various types of materials and dimensions. One of the testers is actuated by a PZT and the other is actuated by a servo motor for a precise displacement control. The specifications of PZT actuated micro tensile tester developed are as follows: the volumetric size of tester is desktop sized of 710$\times$200$\times$270 $mm^3$; the minimum load capacity and the load resolution in the load cell of 1N are 3 mN and 0.1 mN respectively; the full stroke and the stoke resolution of piezoelectric actuator are 1 mm and 10nm respectively. A special automatic specimen installing equipment is applied in order to prevent unexpected deformation and misalignment of specimens during handling of specimen for testing.

  • PDF

Tests of Slab-Column Connections with Partially Debonded Reinforcement under Cyclic Lateral Loading (부분적인 비 부착 철근을 갖는 슬래브-기둥 접합부의 반복 횡하중 실험)

  • Choi, Jung-Wook;Song, Jin-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.13-16
    • /
    • 2006
  • This article summarizes tests conducted on two full-scale interior slab-column connections with and without partially debonded reinforcement subjected to cyclic loading. Each test specimen consisted of a 4.2m square slab with a 355mm square column protruding 1.5m above and below the slab. The slab thickness was 152mm. The specimen with partially debonded reinforcement exhibited more lateral drift capacity than did the specimen with fully bonded reinforcement. With partial debonding of the flexural reinforcement, cyclic load appeared to produce less damage to the connection in the vicinity of the slab-column joint region.

  • PDF

Hybrid infrared-visible multiview correlation to study damage in a woven composite complex-shaped specimen

  • Andrija Zaplatic;Zvonimir Tomicevic;Xuyang Chang;Ivica Skozrit;Stephane Roux;Francois Hild
    • Coupled systems mechanics
    • /
    • v.12 no.5
    • /
    • pp.445-459
    • /
    • 2023
  • In this study, a cyclic tensile test on a notched butterfly specimen made of woven glass fiber composite was performed on a modified Arcan fixture. During the mechanical test, the sample was monitored with a hybrid stereoscopic system comprised of two visible lights and one infrared camera. The visible light cameras were employed for kinematic measurements using a finite-element-based multiview correlation technique. A semi-hybrid correlation approach was followed, providing Lagrangian temperature fields of the Region of Interest. Due to the complex composite architecture and specimen shape, localized shearing was observed during the tensile loading. Furthermore, asymmetrical damage developed around the notches as revealed by localized strains and thermal hot spots.