• Title/Summary/Keyword: Full Rate

Search Result 1,774, Processing Time 0.026 seconds

Phonon Scattering and Impact ionization for Silicon using Full Band Model at 77K (풀밴드 모델을 이용한 77K Si의 포논산란 및 임팩트이온화에 관한 연구)

  • 유창관;고석웅;정학기;이종인
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.552-554
    • /
    • 1999
  • Phonon scattering and impact ionization models have been presented to analyze hot carrier transport in high energy region, using full band model and Fermi's golden rule. We have investigated temperature dependent properties for impact ionization process of Si using realistic energy band structures at 77K and look. The realistic full band model, obtained from the empirical pseudopotential method with local from factors, is used to calculate scattering rate. The accurate calculation of impact ionization rate requires the use of a wavevector- and frequency-dependent dielectric function ξ ( q,$\omega$). The empirical phonon scattering rate P$\sub$ph/, is given by deriving from linear function for P$\sub$ph/ versus D(E) since the phonon scattering rate is linearly depended on density of states D(E). Impact ionization rate p,, is calculated from the first principle's theory. and fitted by modified Keldysh formula having power of above 2.

  • PDF

Performance Trial-Test of the Full-Scale Driving Pump for the Large Cavitation Tunnel(LCT) (대형캐비테이션터널(LCT) 실물 구동펌프 성능시운전)

  • Ahn, Jong-Woo;Kim, Gun-Do;Kim, Ki-Sup;Park, Young-Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.6
    • /
    • pp.428-434
    • /
    • 2015
  • The objective of the present study is to analyze the results of the trial-test for the full-scale driving pump, which is arranged in the LCT (Large Cavitation Tunnel). Firstly, the reasons of selecting the final design pump are introduced in terms of the performance analysis in model tests. The trial-test items for the full-scale driving pump are measurements of output current/voltage at the inverter of the main motor and the flow velocity in the LCT test section. The test results show the increase in flow rate of about 10.7% and the decrease in pump head of about 26%, compared with those of final design-pump specification. The motor power has the margin of about 22%. The performance analysis for the full-scale pump is conducted using the commercial code (CFX-10). The delivered power calculated with CFX-10 shows good agreement with that extracted from the full-scale pump test. It is found that CFX-10 is useful to analyze a full-scale pump.

Physiological Response and Growth Performance of Parasenecio firmus under Different Shading Treatments (차광처리에 따른 병풍쌈의 생리반응 및 생장특성)

  • Lee, Kyeong-Cheol;Lee, Hak-Bong;Park, Wan-Geun;Han, Sang-Sup
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.2
    • /
    • pp.79-89
    • /
    • 2012
  • This study was conducted to investigate the chlorophyll contents, photosynthetic characteristics, chlorophyll fluorescence, and growth performance of Parasenecio firmus under changing light environment. Parasenecio firmus was grown under non-treated (full sunlight) and three different shading conditions (88~93%, 65~75% and 45%~55% of full sunlight) for the experiment. Total chlorophyll content, photochemical efficiency (Fv/Fm), T/R ratio, specific leaf area (SLA), leaf area ratio (LAR), and leaf weight ratio (LWR) were increased with increasing shading level, but decreased dark respiration. Therefore, light absorption and light utilization efficiency were improved under the low intensity light. Plants under 65~75% of full sunlight had best maximum photosynthetic rate and net apparent quantum yield in May. On the other hand, the non-treated plants had lower maximum photosynthetic rate, photochemical efficiency, and chlorophyll content than the treated ones. Parasenecio firmus considered to be a sciophyte, is fairly sensitive to high intensity light. If 88-93% of full sunlight lasts for a long period, photosynthetic capacity will be sharply decreased, though limiting light. These results suggest that growth of Parasenecio firmus adapted to 65~75% of full sunlight.

Performance Analysis for The Coordinate Interleaved Orthogonal Design of Space Time Block Code in The Time Selective Fading Channel (시간 선택적 페이딩 환경에서 CIOD 시공간 블록 부호의 성능 분석)

  • Moon, Seung-Hyun;Lee, Ho-Kyoung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.43-49
    • /
    • 2014
  • In this paper, we consider the performance evaluation of space time block code (STBC)) with coordinate interleaved orthogonal design (CIOD) over time selective channel. In case of quasi static channel, STBC-CIOD satisfies full rate and full diversity (FRFD) property with the single symbol decoding. However in the time selective channel, the symbol interference degrades the system performance when we employ the single symbol decoding. We derive the union bound of the symbol error probability by evaluating the pairwise error probability in the first order Markov channel. We also present simulation results of STBC-CIOD with QPSK.

Characteristics of Growth and Root Development of Peucedanum japonicum Seedling by Shading Rate and Container Size (차광율 및 육묘용기 크기에 따른 갯기름나물 유묘의 생장 및 뿌리 발달 특성)

  • Song, Ki Seon;Jeon, Kwon Seok;Yoon, Jun Hyuck;Kim, Chang Hwan;Park, Yong Bae;Kim, Jong Jin
    • Korean Journal of Medicinal Crop Science
    • /
    • v.22 no.5
    • /
    • pp.384-390
    • /
    • 2014
  • This study was carried out in order to investigate the early growth and root development characteristics of Peucedanum japonicum container seedlings. The experiment was performed by containers (128 and 200 cavities containers) and shading levels (0%, 35%, 50% and 75% shading). Germination rate of P. japonicum seeds was getting higher in the lower shading level and the highest in the full sunlight (71.9%). Plant height was the highest under 50% shading of all containers. Fresh weight and dry weight of the shoot (leaves + stem) were the highest under 50% shading of all containers, too. Meanwhile, fresh weight and dry weight of the root per plant were the highest under the full sunlight of 128 cavities container such as 0.34 g and 0.03 g, respectively. Total root length, root project area and root surface area were higher under the full sunlight of 128 cavities container such as 234.5 cm, $6.6cm^2$ and $20.8cm^2$, respectively and the next higher was under 35% shading such as 201.7 cm, $5.9cm^2$ and $18.4cm^2$, respectively. A case of root volume was the highest with $0.15cm^3$ under the full sunlight. As a result of the surveying the whole experiment, it is concluded that the shoot and root of P. japonicum seedling grow nicely by maintaining 35% shading.

Performance Analysis of In-Band Full-duplex Communication Systems with Self-Interference Cancellation (동일대역 전이중 방식 통신 시스템에서 자기간섭 제거에 따른 성능 분석)

  • Wang, Woowan;Park, Hyuncheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.3
    • /
    • pp.331-337
    • /
    • 2016
  • In this paper, we analyze performances of in-band full-duplex communication system and self-interference (SI) suppression methods in environment where there exists the SI signal. The SI has to be removed to achieve required error rate performance of the system in order - propagation domain, analog domain and digital domain. In propagation domain, the SI signal is attenuated by separating transmitted and received beams physically. In analog and digital domain, after reconstruction of the SI signal using channel estimates and transmit signal, the SI signal can be cancelled from the desired signal. In this paper, assuming that the SI signal can be sufficiently reduced in propagation domain, we demonstrate that the in-band full-duplex communication system can achieve the target error rate by suppressing the SI signal in order - analog and digital domain, based on channel estimates that can be obtained by the method of Least squares.

Effect of Strain Rate and Pre-strain on Tensile Properties of Heat-treated A5082 and A6060 Aluminium Wrought Alloys (열처리한 A5082와 A6060합금의 인장특성에 미치는 변형율속도 및 예비변형율의 영향)

  • Lee, Choongdo
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.33 no.4
    • /
    • pp.161-172
    • /
    • 2020
  • The tensile property of A5082 and A6060 aluminium wrought alloys was investigated, in terms of the strain rate sensitivity on alloy conditions by heat treatment and bake hardenability on pre-strain prior to strain ageing. The tensile test was carried out in a range of strain rate of 4.17 × 10-5 s-1 ~ 4.17 × 10-5 s-1 in room temperature and the nominal range of pre-strain was 3.0 ~ 10.5%. The tensile deformation of A5082 alloys is characterized as typical case of dynamic strain ageing with negative strain rate sensitivity for all conditions, and the tensile strength indicates a similar level regardless of alloy conditions, except only in full annealed condition. The stress-relief annealing on A6060 alloys can induce practical decrease in strength level of over approximately 100 MPa without any ductility loss, compared to as-rolled condition, while a full annealed and aged condition leads remarkable strengthening effect with the decrease of tensile elongation. Additionally, the bake hardenability of A5082 alloy by strain ageing indicates a negative dependence upon the increase of pre-strain, while A6060 alloy exhibits a positive sign even in low level relatively compared with conventional SPCC.

A Study on the Characteristics of Two-Step-Flow-Control Fluidic Device (2단 유량제어 Fluidic Device의 특성에 관한 연구)

  • Cho, Bong-Hyun;Bae, Yoon-Yeong;Park, Jong-Kyun;Yoo, Seong-Yeon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.3 s.12
    • /
    • pp.53-61
    • /
    • 2001
  • Vortex type Fluidic Device(FD) which is installed at the bottom of Safety Injection Tank(SIT) controls the discharge flow rate from the tank. In case of loss of coolant accident the injection water flows into primary system in two steps; initial high flow rate for certain period of time and subsequent low flow rate. By two-step control of the discharge flow rate, FD can ensure the effective use of water in the tank. A small-scale FD has been tested to obtain a required flow characteristics maintaining full pressure and height of prototype, which are the major contributing parameters. Through the testing of many different arrangements of internal geometry of FD, most appropriate one was selected and its performance data was obtained. As characteristics of FD, time dependent Euler number, flow rate and pressure are presented and discussed. Also a method to predict the full size FD is presented.

  • PDF

Surface roughness prediction with a full factorial design in turning (완전요인계획에 의한 선삭가공시 표면거칠기 예측)

  • Yang, Seung-Han;Lee, Young-Moon;Bae, Byong-Jung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.1 no.1
    • /
    • pp.133-140
    • /
    • 2002
  • The object of this paper is to predict the surface roughness using the experiment equation of surface roughness, which is developed with a full factorial design in turning. $3^3$ full factorial design has been used to study main and interaction effects of main cutting parameters such as cutting speed, feed rate, and depth of cut, on surface roughness. For prediction of surface roughness, the arithmetic average (Ra) is used, and stepwise regression has been used to check the significance of all effects of cutting parameters. Using the result of these, the experimental equation of surface roughness, which consists of significant effects of cutting parameters, has been developed. The coefficient of determination of this equation is 0.9908. And the prediction ability of this equation was verified by additional experiments. The result of that, the coefficient of determination is 0.9718.

  • PDF