• 제목/요약/키워드: Full Load

검색결과 1,450건 처리시간 0.025초

RF Generator Design for High-quality Power at Light Load

  • Hee Sung Shin;Shin Ui Lee;Kyung Hyun Lim;Euihoon Chung
    • 반도체디스플레이기술학회지
    • /
    • 제23권2호
    • /
    • pp.100-106
    • /
    • 2024
  • To generate the plasma required in dry cleaning processes, the plasma chamber must be supplied with a high-quality AC voltage with a voltage of more than 1 kV and a frequency of 400 kHz. In the existing research, many methods to supply high power have been studied, but how to improve the quality of the power for high-quality plasma has been relatively little studied. In this paper, we propose a study to improve the quality of RF power circuit for high-quality plasma generation in dry cleaning method. Existing methods in the environment of full-bridge-based RF power circuits must perform PWM duty control in the light load region. This causes distortions in the waveform, resulting in poor power quality, which directly leads to poor plasma quality. To solve these problems, a half-bridge switching method is proposed and the improvement in waveform quality is verified. To verify the feasibility of the design and control algorithm proposed in this paper, an RF power circuit prototype is fabricated and the proposed design and control method is verified through simulation and actual experiments under dummy load.

  • PDF

PLL을 이용한 공진부하 MOSFET 인버어터의 주파수 추종제어계 (Frequency Follow-up Control System of Resonant Load MOSFET Inverter using PLL)

  • Kim, Joon-Hong;Joong-Hwan kim
    • 대한전기학회논문지
    • /
    • 제35권7호
    • /
    • pp.272-277
    • /
    • 1986
  • The system that follows to the resonance frequency of high frequency MOSFET inverter and varies according to the changes of load characteristics is proposed. Also we suggested a method how to select the resonant load type between series and parallel circuit for a given inverter type. It leads to the conclusion that in the case of high impedance loads, parallel resonant circuits are preferable, on the other hand, for low impedance loads, series resonant circuits are more preferable. For frequency tracking, a PLL circuit is used as main control element to detect the phase difference of current and voltage of load. The realized apparatus composed of control circuit and voltage type full-bridged MOSFET elements as main parts of inverter. A stable frequency follow-up characteristics are obtained for 1.2MHz, 1.5KW high frequency output and power is always supplied to the load with unity power factor.

  • PDF

國産 디이젤機關의 汚染物質 排出特性에 關한 硏究 (A Study on Characteristics of Exhaust Emissions from Domestic Used Diesel Engines)

  • 趙康來;金良均;董宗仁;嚴明道
    • 한국대기환경학회지
    • /
    • 제1권1호
    • /
    • pp.83-92
    • /
    • 1985
  • In odrder to survey the emission level of air pollutants from diesel vehicles, was measured CO, HC, NOx and smoke of 4 types of domestic-use diesel engines under various conditions. The emission of CO, HC and NOx tested by 6-Mode test method and smoke emission by full load test met the permissible vehicle emission standard. Pollutant emission rates of diesel engines were different according to engine operating conditions, that is, engine load and engine speed. Generally, CO and HC was emitted more at low load and NOx at high load but the trend was quite different by the type of engines. In exhaust gas, $NO_2$ portion of NOx emission was high, specially at low speed and low load. The correlation equation between CLD(NOx) and NDIR(NO) method of nitrogen of nitrogen oxides analysis was y = 1.10x - 3.48 (y: CLD method) as a result of 6-mode test.

  • PDF

Interface friction in the service load assessment of slab-on-girder bridge beams

  • Seracino, R.;Kerby-Eaton, S.E.;Oehlers, D.J.
    • Steel and Composite Structures
    • /
    • 제5권4호
    • /
    • pp.259-269
    • /
    • 2005
  • Many slab-on-girder bridges around the world are being assessed because they are approaching the end of their anticipated design lives or codes are permitting higher allowable loads. Current analytical techniques assume that the concrete and steel components act independently, typically requiring full-scale load testing to more accurately predict the remaining strength or endurance of the structure. However, many of the load tests carried out on these types of bridges would be unnecessary if the degree of interaction resulting from friction at the steel-concrete interface could be adequately modeled. Experimental testing confirmed that interface friction has a negligible effect on the flexural capacity of a slab-on-girder beam however, it also showed that interface friction is significant under serviceability loading. This has led to the development of an improved analytical technique which is presented in this paper and referred to as the slab-on-girder mixed analysis service load assessment approach.

A Study on Load Vibration Control in Crane Operating

  • Le, Nhat-Binh;Lee, Dong-Hun;Kim, Tae-Wan;Kim, Young-Bok
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2017년도 추계학술대회
    • /
    • pp.58-60
    • /
    • 2017
  • In the offshore crane system, the requirements on the operating safety are extremely high due to many external factors. This paper describes a model for studying the dynamic behavior of the offshore crane system. The obtained model allows to evaluate the fluctuations of the load arising from the elasticity of the rope. Especially, in this paper, the authors design control system in which just winch rotation angle and rope tension are used without load position information. The controller design based on input-output feedback linearization theory is presented which can handle the effect of the elasticity of the rope and track the load target trajectory input. Besides that, a full order observer is designed to estimate unknown states. Finally, By the experiment results, the effectiveness of proposed control method is evaluated and verified.

  • PDF

함정용 탐색레이더 안테나의 구동 토크 분석 및 감쇄에 대한 연구 (Study on Analysis of Driving Torque and Reduction for Naval Surveillance Radar Antenna)

  • 김승우;양윤석
    • 한국군사과학기술학회지
    • /
    • 제12권3호
    • /
    • pp.388-395
    • /
    • 2009
  • Surveillance Radar System for naval vessels is a primary core sensor for command and fire control, and provides CFCS(Command and Fire Control System) information for 3-D surveillance and fire control. It's composed of Antenna, Transmitter/Receiver, Signal Processor, and Air drier, which are installed on and under deck. They should be designed and produced in order to endure at any operating circumstances. This paper analyzes load of a driving part for driving the antenna considering factors under external operating circumstances, and proposes a condition of load for maintaining fixed RPM through analyzing internal load of the driving part, and how to reduce the load to meet the condition. This paper is verified through experimental studies.

새로운 영전압 스위칭 방식을 이용한 고효율 하프-브릿지 컨버터 (New Zero-Voltage-Switching Method for High Efficiency Half-Bridge Converter)

  • 이성세;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.25-27
    • /
    • 2006
  • This paper proposes a new full ZVS-range asymmetrical half bridge converter. It uses the variable transient current build-up technique with the load variations. The current build-up is accomplished by using the secondary synchronous switch control. Due to the blocking capacitor in secondary side, the voltage applied to leakage inductor varies with the load variations during current build-up period. Therefore, the unnecessary current build-up of leakage inductor current in heavy load condition is prevented and more current build-up in medium and light load condition is achieved for ZVS operation. That is, the variant current build-up with the load variation is accomplished for the ZVS operation. Furthermore, the DC offset of the transformer magnetizing current is also eliminated and the utilization of magnetic core is maximized.

  • PDF

Decoupled Load Flow 알고리즘의 유연한 대안 알고리즘들의 개발에 관한 연구 (Development of Alternative Algorithms to the Decoupled Load Flow)

  • 이승철;박상수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.248-250
    • /
    • 1999
  • 본 논문에서 제안된 조류계산 알고리즘은 Jacobian의 off-diagonal 부 행렬을 완전히 무시하는 Decoupled Load Flow(DCL) 알고리즘들의 유연한 대안으로 반복(iteration)당 최소한의 추가 계산 부담으로 Jacobian의 off-diagonal 부분의 효과를 부분적으로 반영함에 의해 수렴 특성을 향상시킬 수 있다. 제안된 방법들은 특히 Fast Decoupled Load Flow(FDL)로 대표되는 DCL들의 수렴특성이 불안정해질 경우, 효과적으로 수렴특성을 향상시킬 수 있다. 제안된 알고리즘들은 Newton-Raphson Load Flow(NRL) 방법에서 Jacobian의 off-diagonal 부분의 효과를 점진적으로 제거하는 방법으로 유도하였고, 간략화 과정에서는 Neuman series expansion을 사용하였다. 실험결과 제안된 알고리즘들은 반복횟수와 전반적인 수렴 속도에서 확실한 성능향상을 보여주었다. 제안된 알고리즘들은 특히 DCL의 수렴성능이 문제가 있을 시 full NRL 대신에 적용할 수 있는 가능성이 있어 조류계산 시간을 단축해 줄 수 있을 것으로 기대된다.

  • PDF

냉난방부하 계산의 단순화 모델링 기법 적용 타당성 검토에 관한 연구 (A Study on Validity of Applying Simplify modeling Method for Heating/Cooling Load Calculation)

  • 강윤석;박종일;임병찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1386-1391
    • /
    • 2008
  • As the time goes by, the energy use in buildings are increasing threateningly. So, it is important to have an accurate energy load calculation for buildings. The accurate energy simulation program carries numerous input data. So, our purpose of this study is to verify the application of simplify modeling method which eliminates coordinates of building components instead of using full coordinates by using DOE2. After comparing original modeling method with simplify modeling method, we applied PAF for daylighting control in the building to verify the application of daylighting control in simplify modeling method. The results shows that there are little difference between original modeling and simplify modeling. Also it showed that application of daylighting control has little difference between original modeling so it is feasible to adapt simplify modeling. These results reveals that the application of simplify modeling is possible to predict energy load and use of the building.

  • PDF

배열회수보일러의 부하변동 운전에 따른 과열기 튜브들의 응력거동 (Stress Behaviors of Superheater Tubes under Load Change Operation in HRSG)

  • 정재헌;송정일
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.33-39
    • /
    • 2008
  • The purpose of this study is not only to evaluate the stress behavior of tubes in superheater in HRSG during the load change operation but also to find root causes of failure from stress behavior. Firstly, temperature during operation was collected to perform stress analysis from actual HRSG. Part load and full load stress analysis which can be represented as the whole load change operations were performed using commercial finite element software. The possibility that can lead to tubes failure is found by stress analysis and its results is compared with metallurgical mircrostructure of failed tube which was taken from actual HRSG.