• 제목/요약/키워드: Full Load

검색결과 1,447건 처리시간 0.025초

ZVS 기법을 사용한 위상제어 PWM FB DC/DC 컨버터 (Phase-shifted PWM FB DC/DC Converter with ZVS Method)

  • 김성철;권순걸;계문호;조기연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.392-394
    • /
    • 1996
  • This paper is to describe how to apply the Phase-shifted Full Bridge 100kHz high frequency soft-switching PWM method to 48[V], 200[A] DC/DC converter. The soft-switching is achieved from light load to full load by using phase-shifted zero voltage switching method with additional capacitors besides the MOSPET's of the right leg even though the leakage inductance of high frequency transformer is designed small. This method can reduce the switching tosses, EMI problems, and increase the effective duty. Also, this paper includes the simulation, analysis, and experiment results of the DC/DC converter unit.

  • PDF

푸시 풀 포워드 컨버터의 주파수 변화, 변압기의 권선비와 1차측 권선 변화에 대한 효율 특성 (Push Pull Forward Converter Efficiency Quility)

  • 전준석;김창선;김태식;임범선;우승훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.36-39
    • /
    • 2003
  • The push pull forward converter is a very suitable circuit for low output voltage, high output current applications with a wide input voltage range. All the magnetic components (output inductor, transformer, input filter) can be integrated into a single core. The integrated magnetics can reduce the number of the magnetic components. Developed the push pull forward converter rating are of 36 $\~$72V input and 3.3V/30A output. In this converter, the efficiency was measured by $76.4\%$ at full load and 82.95$\%$ at full load. The maximum efficiency is up to 83.$\%$ at 200kHz switching frequency, l1A output.

  • PDF

Measured Performance of Full Scale Tieback Walls in

  • Kim, Nak
    • 한국지반공학회지:지반
    • /
    • 제14권3호
    • /
    • pp.5-24
    • /
    • 1998
  • 사질토 지반에서 앵커로 지지된 토류벽의 거동을 연구하기 위하여 텍사스 에이엔엠 대학에 소재한 미국 국립 토질 시험장에 계측기가 장착된 실물 크기의 앵커 토류벽을 시공하였다. 기간 중의 단계별 계측과 시공후의 계측을 실시하여 사질토 지반에서의 앵커 토류벽의 현장 거동을 분석하였다. 시공 단계별 토류벽의 수평 변천, 토류벽의 휨 모멘트, 토류벽의 연직 하중, 배면토의 침하와 앵커 하중을 계측하여 앵커 토류벽의 현장 거동을 분석하여 제시하였다. 사질토 지반에서의 토류벽의 거동 특성을 실측결과와 비교하여 분석하였다.

  • PDF

Characteristics of wind loads on roof cladding and fixings

  • Ginger, J.D.
    • Wind and Structures
    • /
    • 제4권1호
    • /
    • pp.73-84
    • /
    • 2001
  • Analysis of pressures measured on the roof of the full-scale Texas Tech building and a 1/50 scale model of a typical house showed that the pressure fluctuations on cladding fastener and cladding-truss connection tributary areas have similar characteristics. The probability density functions of pressure fluctuations on these areas are negatively skewed from Gaussian, with pressure peak factors less than -5.5. The fluctuating pressure energy is mostly contained at full-scale frequencies of up to about 0.6 Hz. Pressure coefficients, $C_p$ and local pressure factors, $K_l$ given in the Australian wind load standard AS1170.2 are generally satisfactory, except for some small cladding fastener tributary areas near the edges.

고압계통 변류기 동작 특성 검토 (A Study on Performance of Current Transformer in High Voltage System)

  • 최기열;이덕수;박문빈;김희택;장기풍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.5-7
    • /
    • 2006
  • Current transformers(CTs) whose rating is selected per a full load current of a feeder in high voltage system can be easily saturated due to high fault current that may be several hundred times of the full load current of the feeder. However, the protective relay shall operate properly at the fault without mis-operation under the CT saturation. So, in selecting the CT rating, it is necessary to consider the behaviour of CT and a performance of protection scheme in condition where CT can be saturated. In this paper, a performance of CT and a degree of saturation are studied and verified whether its ratings are proper for the operation of the protective relay.

  • PDF

교량용 강ㆍ콘크리트 합성 바닥판의 단위모델에 대한 비선형 해석 (A Nonlinear Analysis on the Unit Model of Steel-Concrete Hybrid Deck for Bridges)

  • 정광회;정연주;구현본;김정호;김병석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.85-91
    • /
    • 2003
  • This paper presents a 3D nonlinear analysis with slip in steel-concrete hybrid deck. In this study, it was founded that the limit slip modulus could classify the states of steel-concrete hybrid deck into three parts as full-composite, partial-composite, and non-composite, considering the longitudinal behavior and end-slip as well as the yield load and ultimate load of it. Also, it proved that the stress of lower steel plate at the support was increased, because of frictional forces by reaction forces in the steel-concrete hybrid deck. The end-slip did not occur near the full-composite state, but it was largely increased as the slip modulus decreased. On the basis of the EC 4, the state of steel-concrete hybrid deck classified into brittle behavior and ductile one using the end-slip of it

  • PDF

전동차용 IGBT형 추진제어장치의 6호선 본선 만차 시험에 관한 연구 (A Study On Full Load Test of IGBT Type Propulsion System for Electric Railway in SMG 6 Line)

  • 박건태;정만규;고영철;방이석;서광덕
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.666-673
    • /
    • 2000
  • This paper describes the full load test results of IGBT VVVF inverter for the railway propulsion system. The 1,650kVA IGBT VVVF inverter has been developed. Therefore, the field test is performed in SMG 6 Line to confirm its the reliability and performance. The train consists of 4M4T(4 Motor car 4 Trailer Car) and the electrical equipment for field test are as follows VVVF inverter 4 sets, 16 traction motors and 2 SIVs. The propulsion system is composed with IC4M(1-Controller 4-Motors). The results of propulsion system which have the excellent acceleration/deceleration and the jerk characteristics as well as starting ability on slope are taken through the field test.

  • PDF

TDX-10 패킷처리기의 성능척정을 위한 트래픽발생기의 설계 (Traffic Generator for Performance Test of the TDX-10 Packet Handler)

  • 정중수;전경표
    • 전자공학회논문지A
    • /
    • 제32A권3호
    • /
    • pp.411-417
    • /
    • 1995
  • Packet switching is an important aspect of ISDN. In the TDX-10 switching system, which is being developed as an ISDN exchange in Korea, the packet switching function is implemented on the basis of Case B scenario of X.31. After implementing the packet switching function the performance test must be executed to check whether the design objectives of performance are satisfied or not. However, it is not easy to set up test environment for performance measurement under full load conditions. This paper presents the design of the traffic generator which enables us to do performance test of the TDX-10 packet handler under full load conditions. To generate packet traffic we change only software programs without any change of the hardware system of the packet handler.

  • PDF

6기통 압축착화 기관의 단일 영역 열방출량 계산 (An One-zone Heat Release Analysis of a 6 Cylinder Compression-Ignition Engine)

  • 신범식;이석영;전광민
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.147-154
    • /
    • 1996
  • An one-zone heat release analysis was studied for a 6 cylinder direct injetction compressionignition engine. The heat transfer constants in this anlysis were calibrated to match the measured fuel energy at 1,000 rpm full load, which was the fuel mass multiplied by the fuel's heating value. The integrated gross heat release values were close to the measured fuel energy at various full load operating conditions. The combustion inefficiency from this calculation was proportional to the smoke of exhaust gas.

  • PDF

Response prediction of a 50 m guyed mast under typhoon conditions

  • Law, S.S.;Bu, J.Q.;Zhu, X.Q.;Chan, S.L.
    • Wind and Structures
    • /
    • 제9권5호
    • /
    • pp.397-412
    • /
    • 2006
  • This paper presents the wind excited acceleration responses of a 50 m guyed mast under the action of Typhoon Dujuan. The response of the structure is reconstructed from using a full finite element model and an equivalent beam-column model. The wind load is modelled based on the measured wind speed and recommendations for high-rise structures. The nonlinear time response analysis is conducted using the Newton Raphson iteration procedure. Comparative studies on the measured and computed frequencies and acceleration responses show that the torsional vibration of the structure is significant particularly in the higher vibration modes after the first few bending modes. The equivalent model, in general, gives less accurate amplitude predictions than the full model because of the omission of torsional stiffness of the mast in the vibration analysis, but the root-mean-square value is close to the measured value in general with an error of less than 10%.