• Title/Summary/Keyword: Fujii

Search Result 132, Processing Time 0.023 seconds

Design Using Finite Element Analysis of a Switched Reluctance Motor for Electric Vehicle

  • Ohyama Kazuhiro;Nashed Maged Naguib F.;Aso Kenichi;Fujii Hiroaki;Uehara Hitoshi
    • Journal of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.163-171
    • /
    • 2006
  • In this paper, a Switched Reluctance Motor (SRM) employed in an electric vehicle (EV) is designed using the finite element method (FEM). The static torque of the SRM is estimated through magnetic field analysis. The SRM temperature rise over operation time is estimated through heat transfer analysis. First, static torque and temperature rise over the time of 600W SRM is included in the experiment set, and are compared with the calculated results using the FEM under the same conditions. The validity of the magnetic field analysis and heat transfer analysis is verified by the comparisons. In addition, a 60 [kW] SRM employed in an EV, whose output characteristics are equal to a 1500 [cc] gasoline engine, is designed under magnetic field analysis and heat transfer analysis.

Photovoltaic Generating System on Ships to Reduce Fossil Fuel Dependence (선박에서 화석연료 의존도 절감을 위한 태양광 발전)

  • Takeshi Katagi;Yoshimi Fujii;Eiichi Nishikawa;Takeshi Hashimoto;Kenji Ishida
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.176-176
    • /
    • 1996
  • The release of polluting gases such as NOx of SOx to the atmosphere from ships is causing increasing concern. To reduce destruction to the marine environment, the value of the utilization of photovoltaic energy is highly appreciated since photovoltaic energy is and alternate clean energy source to fossil fuels. The use of a photovoltaic generating system to supplement diesel engine driven electric power system on ships has been studied. The design of the photovoltaic generating system based on a photovoltaic array is presented in this paper. The amount of NOx and SOx emission is found to be significantly reduced for a small vessel operated within a harbour after a photovoltaic generating system is installed to supplement the diesel engine generator system.

Repair of furcal perforation with mineral trioxide aggregate in dogs

  • Masataka, Suehara;Rie, Fujii;Masayasu, Kuroda;Kensuke, Saito
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.578-578
    • /
    • 2003
  • I. Objectives The purpose of this study was to investigate, histologically, healing in the periodontal tissue after mechanical furcation perforations using Mineral Trioxide Aggregate (PRO ROOTMTA). II. Materials and Methods These experiments were carried out on mandibular and maxilla premolars and molars obtained from 12 dogs more than one year old and which had clinically healthy periodontia. A total of 34 perforations were made. These were divided into Control(9), MTA(25) groups respectively. A sterile round bur (1mm in diameter) was used to create a mechanical perforation in the furcal floor.(omitted)

  • PDF

Numerical Study of Pressure Waves Generated by H-IIA Launch Vehicle at Lift-off

  • Tsutsumi, Seiji;Shimizu, Taro;Takaki, Ryoji;Shima, Eiji;Fujii, Kozo;Arita, Makoto
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.266-271
    • /
    • 2008
  • Generation mechanisms of pressure waves from the H-IIA launch vehicle are analyzed numerically. The Mach wave radiated downstream from wavy shearlayer of supersonic exhaust plume is revealed to be the dominant noise source. Reflecting from the constructions of the launch-pad, the Mach wave turns to propagate to the vehicles. It was also found that the fluctuating supersonic plume entering into the flame duct is the dominant noise source that appears in the flame duct. Then, the pressure wave propagates through the flame duct and is ejected outside to the vehicle.

  • PDF

EFFECT OF $Na_{2}O$ ADDITION ON MAGNETIC PROPERTIES OF $SrZn_{2}-W$ TYPE HEXAGONAL FERRITE

  • Yamamoto, Hiroshi;Fujii, Hiroshi;Mitsuoka, Takayuki
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.735-739
    • /
    • 1995
  • An experiment was carried out to investigate the effect of $Na_{2}O$ additive on the magnetic and physical properties of $SrZn_{2}-W$ type hexagonal ferrite. The specimens were prepared by the conventional manufacturing methods without atmosphere control. It was found that the magnetic properties of SrO.2ZnO.$8Fe_{2}O_{3}$ are considerably improved on adding 1.5wt% $Na_{2}O$. Theoptimum condition of making magnet with suitable properties are as follows : chemical analysis composition : $Sr^{2+}_{0.852}Zn^{2+}_{1.721}Na^{+}_{0.301}Fe^{2+}_{0.723}Fe^{3+}_{15.703}O_{27}$ ; semisintering condition : $1300^{\circ}C\;{\times}\;1h$ in air ; sintering condition : $1250^{\circ}C\;{\times}\;0.5h\;T_{c}=371^{\circ}C,\;H_{A}=1091.5kA/m,\;K_{A}=2.13{\times}10^{5}J/m^{3}\;and\;n_{B}=31.8\mu\textrm{B}$.

  • PDF

Erythrodermic Actinic Reticuloid Is Characterized by the Overspill of Oligoclonal CD8+ Lymphocytes Responsive To Ultraviolet Irradiation

  • Iwatsuki, Keiji;Ohtsuka, Mikio;Matsui, Takashi;Yamamoto, Takenobu;Fujii, Kazuyasu;Yamasaki, Osamu;Tsuji, Kazuhide
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.491-493
    • /
    • 2002
  • Erythrodermic actinic reticuloid (EAR) is a photosensitive disorder characterized by dense lymphocytic infiltration in the sun-exposed areas and an increased number of atypical lymphocytes in the peripheral blood. We have reported 2 patients with EAR with circulating atypical lymphocytes and photosensitivity to both ultraviolet (UV) B and A. Although no clonal proliferation of T-cells was observed in the peripheral blood, CD8+ cells were increased in number in an oligoclonal fashion. A number of proliferating CD8+ cells were small, but most cells expressed bcl-2. These findings suggest EAR is a photosensitivity dermatitis characterized by the overspill of oligoclonal CD8+ lymphocytes responsive to UV irradiation.

  • PDF

Postbuckling strength of an axially compressed elastic circular cylinder with all symmetry broken

  • Fujii, Fumio;Noguchi, Hirohisa
    • Structural Engineering and Mechanics
    • /
    • v.11 no.2
    • /
    • pp.199-210
    • /
    • 2001
  • Axially compressed circular cylinders repeat symmetry-breaking bifurcation in the postbuckling region. There exist stable equilibria with all symmetry broken in the buckled configuration, and the minimum postbuckling strength is attained at the deep bottom of closely spaced equilibrium branches. The load level corresponding to such postbuckling stable solutions is usually much lower than the initial buckling load and may serve as a strength limit in shell stability design. The primary concern in the present paper is to compute these possible postbuckling stable solutions at the deep bottom of the postbuckling region. Two computational approaches are used for this purpose. One is the application of individual procedures in computational bifurcation theory. Path-tracing, pinpointing bifurcation points and (local) branch-switching are all applied to follow carefully the postbuckling branches with the decreasing load in order to attain the target at the bottom of the postbuckling region. The buckled shell configuration loses its symmetry stepwise after each (local) branch-switching procedure. The other is to introduce the idea of path jumping (namely, generalized global branch-switching) with static imperfection. The static response of the cylinder under two-parameter loading is computed to enable a direct access to postbuckling equilibria from the prebuckling state. In the numerical example of an elastic perfect circular cylinder, stable postbuckling solutions are computed in these two approaches. It is demonstrated that a direct path jump from the undeformed state to postbuckling stable equilibria is possible for an appropriate choice of static perturbations.

Condensing Heat Transfer Characteristics on a Heat Pump System Using Non-Azeotropic Refrigerant Mixtures (비공비혼합냉매를 사용하는 열펌프의 응축열전달 특성)

  • 박기원;오후규;김욱중
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.4
    • /
    • pp.1125-1133
    • /
    • 1995
  • Experiments were performed to investigate the condensing heat transfer characteristics of non-azeotropic mixtures of R-22 and R-114 in a heat pump system with a horizontal smooth tube as a condenser. The ranges of parameters, such as heating capacity, mass flow rate of refrigerant and quality were 780-3,480W, 24-71kg/h, and 0-1, respectively. The overall compositions of R-22 in a R-22/114 mixture were 25, 50, 75 and 100 per cent by wight. The results show that the overall condensing heat transfer coefficients for the mixtures were lower than the pure R-22 values. Local heat transfer coefficient of the pure R-22 was hghest at the top of the test tube. The local heat transfer coefficient of R-22/114 (50/50 wt%) at side and bottom of the test tube was higher than that at the top. From the obtained data, a prediction for the condensing heat transfer coefficients of the mixture was done based on the method of Fujii.

Assessment of pushover-based method to a building with bidirectional setback

  • Fujii, Kenji
    • Earthquakes and Structures
    • /
    • v.11 no.3
    • /
    • pp.421-443
    • /
    • 2016
  • When conducting seismic assessment of an asymmetric building, it is essential to carry out three-dimensional analysis considering all the possible directions of seismic input. For this purpose, the author proposed a simplified procedure is to predict the largest peak seismic response of an asymmetric building subjected to horizontal bidirectional ground motion acting in an arbitrary angle of incidence in previous study. This simplified procedure has been applied to torsionally stiff (TS) asymmetric buildings with regular elevation. However, the suitability of this procedure to estimate the peak response of an asymmetric building with vertical irregularity, such as an asymmetric building with setback, has not been assessed. In this article, the pushover-based simplified procedure is applied to estimate the peak response of asymmetric buildings with bidirectional setback. Nonlinear dynamic (time-history) analysis of two six-storey asymmetric buildings with bidirectional setback and designed according to strong-column weak beam concept is carried out considering various directions of seismic input, and the results compared with those estimated by the proposed method. The largest peak displacement estimated by the simplified method agrees well with the envelope of the dynamic analysis response. The suitability assessment of the simplified procedure to analysed building models is made as well based on pushover analysis results.

An enhanced method of predicting effective thickness of corroded steel plates

  • Kaita, Tatsumasa;Appuhamy, J.M. Ruwan S.;Ohga, Mitao;Fujii, Katashi
    • Steel and Composite Structures
    • /
    • v.12 no.5
    • /
    • pp.379-393
    • /
    • 2012
  • Many steel bridge infrastructures in the world are getting older, and a large number of these structures are in need of maintenance, rehabilitation or replacement. Most of them are subjected to corrosion due to exposure to aggressive environmental conditions and inadequate maintenance, causing reduction of their carrying capacities. In order to have an adequate bridge management, it is of paramount importance to develop an efficient, accurate and rapid condition assessment method which can be used to make reliable decisions affecting the cost and safety. Therefore, a simple and accurate method of calculating remaining yield and tensile strength by using a concept of representative effective thickness with correlation of initial thickness and maximum corroded depth is proposed in this study, based on the results of many tensile coupon tests of corroded plates obtained from a steel plate girder with severe corrosion, used for about 100 years. Furthermore, a strength reduction diagram which will be very useful for bridge inspection engineers to make rational decisions about the maintenance management of aged steel bridge infrastructures is presented.