• Title/Summary/Keyword: Fuel concentration

Search Result 1,367, Processing Time 0.038 seconds

Current status on Miscanthus for biomass (바이오매스로서의 억새에 대한 연구 동향)

  • Seo, Sang-Gyu;Lee, Jeong-Eun;Jeon, Seo-Bum;Lee, Byung-Hyun;Koo, Bon-Cheol;Suh, Sae-Jung;Kim, Sun-Hyung
    • Journal of Plant Biotechnology
    • /
    • v.36 no.4
    • /
    • pp.320-326
    • /
    • 2009
  • The carbon dioxide concentration of the atmosphere is projected to increase by almost 50% over the first 50 years of this century. The major cause of this increase is continued combustion of fossil fuels. As a result, the significant changes in climate that have already occurred will be amplified, in particular a global temperature increase. Renewable energy production has a central role to play in abating net $CO_2$ emissions to a level that will arrest the development of global warming. Especially, biomass crops are becoming increasingly important as concerns grow about climate change and the need to replace carbon dioxideproducing fossil fuels with carbon-neutral renewable sources of energy. To succeed in this role, biomass crop has to grow rapidly and yield a reliable, regular harvest. A prime candidate is Miscanthus, or Asian elephant grass, a perennial species that produces over 3 metres of bamboo-like stems in a year. Miscanthus species are typically diploid or tetraploid. Hybrids between species with different ploidy levels result in the highly productive triploid hybrids, M. ${\times}$ giganteus. Here we will detail the Miscanthus characteristics desired of a biomass fuel crop.

Basic Study on Diffusion Branch of Tribrachial Flame with the Variation of Flammability Limits and Heat Loss Under Small Fuel Concentration Gradient (미소 농도구배 조건에서 열손실 및 가연한계가 삼지화염의 확산화염에 미치는 영향에 대한 기초 연구)

  • Cho, Sang-Moon;Lee, Min-Jung;Kim, Nam-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.505-513
    • /
    • 2010
  • The tribrachial flame has attracted interest as a basic structure of the flame edge. This flame structure helps understand stabilization of laminar flames and re-ignition of turbulent flames. A number of analytical and experimental studies have been carried out on the tribrachial flame. However, the effect of the variation of the flammability limits on the structure of the tribrachial flame has not been studied in detail. In this study, the effect of non-symmetric flammability limits on the flame structure was investigated by adopting a simple numerical scheme based on several laminar flame theories. A fixed velocity field was considered and boundary matching algorithm was used on the premixed branch. The variation of the diffusion branches under the non-symmetric flammability limits and heat loss was investigated. The formation and extinction of the diffusion branch behind the premixed branch were successfully described. This basic study can help understand the fundamental structure of the flame and can form the basis of subsequent detailed studies.

Evaluation of Design Fire Curves for Gas Fires in a Compartment Using CFAST (CFAST를 이용한 구획실 가스화재의 디자인 화재곡선 평가)

  • Baek, Bitna;Oh, Chang Bo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.7-16
    • /
    • 2018
  • In this study, the prediction performance of design fire curves (DF) was evaluated for gas fires in a compartment by using CFAST. The CFAST simulations adopted the 2-stage DF suggested by the previous study and the Quadratic and Exponential DF suggested by Ingason. It was found by comparing the simulation and experimental results that the overall prediction performance of the design fire cures for the spatially-averaged temperature and concentrations of $O_2$ and $CO_2$ was, from the most reasonable to the most inaccurate, 2-stage DF > Quadratic DF > Exponential DF. The CFAST simulation could not predict for the difference in the spatially-averaged temperature and concentrations of $O_2$ and $CO_2$ at door and inner side locations in a compartment. The CFAST simulations also showed a limitation in the prediction of the spatially-averaged temperature at lower layer and the concentration of CO.

Determination of Forward Dissolution Rate of Glass by a Single-Pass Flow-Through Test (Single-Pass Flow-Through Test방법에 의한 유리의 정용해율 측정)

  • Kim Seung-Soo;Chun Kwan-Sik;Choi Jong-Won;Kim Sung-Ki;Hahn Pil-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.335-340
    • /
    • 2005
  • The forward dissolution rate of a borosilicate waste glass was determined as an interlaboratory study(ILS) testing program for the evaluation of precision in the measurement of the dissolution rate or a waste glass using a single-pass flow-through(SPFT) test, whose conducting practice has been written for standardization through American Society for Testing and Materials (ASTM). A simulated low-activity waste glass powder with a size of 100/200 mesh was dissolved by lithium buffer solution (pH=10) at 70? under Ar atmosphere. By plotting the dissolution rates as a function of silicon and boron concentration in eluate, the forward dissolution rate of the glass was obtained as about $2.7\times10^{-5}g{\cdot}m{\cdot}s^{-1}$ in our laboratory.

  • PDF

An Experimental Study on the Erosion of a Compacted Calcium Bentonite Block (압축된 칼슘벤토나이트 블록의 침식에 대한 실험적 연구)

  • Baik Min-Hoon;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.341-348
    • /
    • 2005
  • Bentonite has been considered as a candidate buffer material in the underground repository for the disposal of high-level radioactive waste because of its low permeability, high sorption capacity, self sealing characteristics, and durability in nature. In this study, the potential for separation of bentonite particles caused by the groundwater erosion was studied experimentally for a Korean Ca-bentonite under the relevant repository conditions. Results showed that bentonite particles can be generated at the bentonite/granite interface and mobilized by the water flow although the intrusion of bentonite into fracture by swelling pressure was observed to be small. Different processes of mobilization of theses colloids from the compacted bentonite block have been identified in this study. The concentration of particles eluted in water was increased as the flow rate increased. Thus the result reveals that the erosion of the bentonite surface due to the groundwater flow together with intrusion processes is the main mechanism that can mobilize bentonite colloids in the fracture of the granite.

  • PDF

The Comparison on Treatment Method of Liquid Radioactive Waste in Yonggwang #3&4 and #5&6 (영광 3&4와 5&6호기에서 액체 방사성폐기물 처리방법의 비교)

  • Yeom, Yu-Seon;Kim, Soong-Pyung;Lee, Seung-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.219-230
    • /
    • 2004
  • Most of the low-level liquid radioactive wastes generated from PWR plants are classified into high or low total suspended solid(HTDS or LTDS), and into radiochemical and radioactive laundry waste. Although the evaporation process has a high decontami- nation ability, it has several problems such as corrosion, foam, and congestion. A new liquid waste disposal process using the ion-exchange demineralizer(IED), instead of the current evaporation process, has been introduced into the Yonggwang NPP #5 and 6. These two methods have been compared to understand the differences in this study. Aspects compared here were the released radioactivity amount of the liquid radioactive wastes, the dose of off-site residents, the decontamination factor, and the amount of the solid radioactive wastes. The IED system is designed to discharge higher radioactivity about 20% than the evaporating system, and the actual radioactivity released from the evaporating and IED system were 0.473mCi and 1.098mCi, respectively. The radioactivity released from the IED was 2.32 times higher than that of the evaporating system. The dose of off-site residents was $2.97{\times}10^{-6}$mSv for the evaporating system, and $6.47{\times}10^{-6}$mSv for IED. The decontamination factor(DF) of the evaporator is, in most cases, far lower than the lower limits of detection(LLD) with the Ge-Li detector. Due to the low concentration of the liquid wastes collected from the liquid waste system, the decontamination factor of IED is very low. Since there is not enough data on the amount of solid radioactive wastes generated by the evaporation system, the comparison on these two systems has been conducted on the basis of the design, and the comparison result was that the evaporating system generated more wastes about 40% than IED.

  • PDF

Prediction of the Dynamic Adsorption Behaviors of the Uranium and Cobalt Ions in a Fixed Bed by Surface Modified Activated Carbon (표면개질 활성탄을 이용한 고정층에서 우라늄 및 코발트 이온의 동적 흡착거동 모사)

  • Geun-IL Park;Jung-Won Lee;Kee-Chan Song;In-Tae Kim;Kwang-Wook Kim;Myung-Seung Yang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.81-92
    • /
    • 2003
  • In order to predict the dynamic behaviors of uranium and cobalt in a fixed bed at various influent pH values of liquid waste, the adsorption system is regarded as a multi-component adsorption between each ionic species in the solution. Langmuir isotherm parameters of each species were extracted by incorporating equilibrium data with the solution chemistry of the uranium and cobalt using IAST. Prediction results were in good agreement with the experimental data, except for a high concentration and pH. Although there was some limitations in predicting the cobalt adsorption, this method may be useful in analyzing a complex adsorption system where various kinds of ionic species exist in a solution.

  • PDF

Impact Analysis of Air Quality of Mobile Sources using Microscopic Emission and Dispersion Model (미시적 탄소배출량 및 대기확산 모형을 이용한 이동오염원에 의한 대기 질 영향 분석)

  • Yang, Choong Heon;Yang, Inchul;Yoon, Chun Joo;Sung, Jung Gon
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.167-175
    • /
    • 2013
  • PURPOSES : The objective of this study is to investigate the capability of the combined model of traffic simulation, emission and air dispersion models on the impact analysis of air quality of mobile sources such as vehicles. METHODS : The improvement of the quality of life brings about the increasing interest of the public environment. Many endeavors including the travel demand management, the application of the state-of-the-art ITS technologies, the promotion of eco-friendly vehicles have been tried in transportation area to reduce the modal emissions. Especially, it is expected that the increasing number of eco-friendly vehicles in the road network would be able to reduce the pipe-tail emissions tremendously. From this perspective, we have performed a study on the impact analysis of the popularization of the eco-friendly vehicle in the place of the fossil fuel energy powered vehicles on the surrounding air quality using the combined framework of microscopic traffic simulation, emission and air dispersion model. RESULTS : The combined model successfully captured the effect of moving to the eco-friendly vehicles on the air quality, and the results showed that the increasing usage of eco-friendly vehicles can improve the surrounding air quality tremendously and that the air dispersion model plays a crucial role in the investigation of the air quality change around the main corridor. CONCLUSIONS : This study demonstrated the capability of the combined model showing the spatio-tempral change of emission concentration.

Effect of Gas Diffusion Layer Property on PEMFC Performance (기체확산층 물성이 고분자전해질 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.568-574
    • /
    • 2020
  • Gas diffusion layer (GDL) is one of the main components of PEMFC as a pathway of reactants from a flow field to an electrode, water transport in reverse direction, heat management and structural support of MEA. In this study, the effect of GDL on fuel cell performance was investigated for commercial products such as 39BC and JNT30-A3. Polarization curve measurements were performed at different flow rates and relative humidity conditions using 25 ㎠ unit cell. The parameters on operating conditions were calculated using an empirical equation. The electrical resistance increased as the GDL PTFE content increased. The crack of microporous layer had influence on the concentration loss as water pathway. In addition, the ohmic resistance increased as the relative humidity decreased, but decreased as the current density increased due to water formation. Curve fitting analysis using the empirical equation model was applied to identify the tendency of performance parameters on operating conditions for the gas diffusion layer.

Fabrication of Nano-sized ZnO Colloids from Spray Combustion Synthesis (SCS) (분무연소합성(SCS)법에 의한 나노크기 산화아연(ZnO) 콜로이드의 제조)

  • Lee, Sang-Jin;Lee, Sang-Won;Jun, Byung-Sei
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.1
    • /
    • pp.76-80
    • /
    • 2004
  • Nano-sized ZnO colloids were prepared by use of spray combustion method. for combustion reaction, $Zn(NO_3)_2{\cdot}6H_2O$ and $CH_6N_4O$ were employed as an oxidizer and a fuel. Exothermic peak was shown at $230^{\circ}C$ by DTA/TGA, and it was considered as a combustion reaction followed by ignition of the precursor mixture. In case of spray combustion method, because insufficient contents of molecules and radicals generated from precursor droplets may lead an incomplete igmition, the ignition temperature of combustion chamber was chosen at $500^{\circ}C$. For diminishing aerosol coagulation, the droplet number concentration was reduced by filter media. The fluid was laminar with 2.5 seconds of aerosol residence time. The synthesized colloids had spherical shape with 180 nanometer size, and the crystalline phase was ZnO with hexagonal structure.