• Title/Summary/Keyword: Fuel cell system

Search Result 1,369, Processing Time 0.028 seconds

Fuel cell system for SUAV using chemical hydride - II. Lightweight fuel cell propulsion system (화학수소화합물을 이용한 소형 무인항공기용 연료전지 시스템 연구 - II. 경량 연료전지 추진 시스템)

  • Hong, Ji-Seok;Park, Jin-Gu;Sung, Myeong-Hun;Jeon, Chang-Soo;Sung, Hong-Gye;Shin, Seock-Jae;Nam, Suk-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.233-239
    • /
    • 2013
  • A 100 W fuel cell system using chemical storage method has been applied for a propulsion system of the SUAV(Small Unmanned Aerial Vehicle). A fuel cell and battery have been combined for both the small/light hydrogen generation control system and the hybrid power supply system. A small hydrogen generation device was implemented to utilize NaBH4 aqueous solution and dead-end type PEMFC system, which were evaluated on the ground and by the flight tests. The system pressurized at a 45kpa stably operates and get higher fuel efficiency. The pressure inside of the hydrogen generation control system was maintained at between 45 kPa and 55 kPa. The 100W fuel cell system satisfies the required weight and power consumption rate as well as the propulsion system, and the fuel cell system performance was demonstrated through flight test.

Compensation Scheme for Output Voltage Distortion in Fuel Cell Stack with Internal Humidifier (내부 가습형 연료전지 스택의 출력전압 왜곡 보상기법)

  • Koo, Keun-Wan;Woo, Dong-Gyun;Joo, Dong-Myoung;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • In this paper, the characteristics of portable fuel cell system are introduced and the dynamic response of output voltage of fuel cell stack with internal humidifier is analyzed. When the output of the fuel cell (FC) stack is short-circuited for humidification, the output voltage of the FC stack rapidly drops. In order to maintain the load voltage in the required range, dynamic compensation methods are proposed: 1) installing a capacitor behind the output of the FC stack; 2) utilizing the bi-directional converter. Especially, bi-directional converter is used when short of the FC output is detected or predicted by algorithm using data which is measured during previous three cycles. These methods are simulated by PSIM 9.0, then experimental results from the fuel cell system prototype verify the validity of the proposed methods.

CFD-based Flow Simulation Study of Fuel Cell Protective Gas (CFD를 활용한 연료전지 모듈 보호가스 유동 연구)

  • Kwon, Kiwook;Lim, Jongkoo;Park, Jongcheol;Shin, Hyun Khil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.86.1-86.1
    • /
    • 2011
  • To improve the safety, the fuel cell operate inside a pressurized enclosure which contains inert gas so called protective gas. The protective gas not only prevents the mixture of hydrogen and oxygen, but also removes the water in the vessel with the condenser. This study presents the details of the flow optimization in order to reduce the humidity in the fuel cell housing. The protective gas flow in the fuel cell container is studied by Computational Fluid Dynamics(CFD) simulations. This study focuses on optimizing the geometry of an protective gas circulation system in fuel cell module to reduce the humidity in the vessel. CFD analysis was carried out for an existing model to understand the flow behavior through the fuel cell system. Based on existing model CFD results, geometrical changes like inlet placement, optimization of outlet size, modification of fuel cell module system are carried out, to improve the flow characteristics. The CFD analysis of the optimized model is again carried out and the results show good improvement in protective gas flow behavior.

  • PDF

A Power Control Scheme of a Fuel Cell Hybrid Power Source

  • Song, Yu-Jin;Han, S.B.;Park, S.I.;Jeong, H.G.;Jung, B.M.;Kim, G.D.;Yu, S.W.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.183-187
    • /
    • 2008
  • This paper describes a power control scheme to improve the performance of a fuel cell battery hybrid power source for residential application. The proposed power control scheme includes a power control strategy to control the power flow of the fuel cell hybrid power system and a digital control technique for a front-end dc-dc converter of the fuel cell. The power control strategy enables the fuel cell to operate within the high efficiency region defined by the polarization curve and efficiency curve of the fuel cell. A dual boost converter with digital control is applied as a front-end dc-dc converter to control the fuel cell output power. The digital control technique of the converter employs a moving-average digital filter into its voltage feedback loop to cancel the low frequency harmonic current drawn from the fuel cell and then limits the fuel cell output current to a current limit using a predictive current limiter to keep the fuel cell operation within the high efficiency region as well as to minimize the fuel cell oxygen starvation.

  • PDF

Optimization of Fuel Processing Unit of Fuel Cell System using Six-Sigma Technique (Six-sigma 기법을 이용한 연료전지시스템 연료저리장치 최적화)

  • Chung, Kyung-Yong;Kim, Sun-Hoe
    • Journal of Digital Convergence
    • /
    • v.10 no.2
    • /
    • pp.225-229
    • /
    • 2012
  • A reformer for a small fuel cell system is an apparatus which converts hydrocarbon fuel into hydrogen-rich gas. Among many indices of a reformer, the most crucial index of a reformer is CO concentration in the off-gas out of reformer which must be controled under 5ppm for the efficiency and performance of a system. This paper suggests the criteria of a reformer operation for the stability of a reformer in a fuel cell system by deducing crucial indices and improving processes. The six-sigma technique was applied to verify the optimum control and operation of a reformer of a fuel cell combined heat and power system. The result of temperature control of each parts of a reformer system is the concentration of CO which is the most important factor for the operation of a fuel cell system. The temperature of the parts of a reformer, MTS, LTS and Prox, were controled so that the concentration of CO.

Development of the 5kW Class Polymer Electrolyte Fuel Cell System for Residential Power Generation (5kW 급 주택용 고분자 연료전지 시스템)

  • Yang, Tae-Hyun;Park, Gu-Gon;Yoon, Young-Gi;Lee, Won-Yong;Yoon, Wang-Lai;Kim, Chang-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.1
    • /
    • pp.35-45
    • /
    • 2003
  • Polymer electrolyte fuel cells(PEFC) have been considered to be a suitable candidate for residential, portable and mobile applications, due to their high efficiency and power density, even at low operating temperature. KIER developed a 5kW class PEFC system for residential application and operated the system for over 1,000 hours. To develop a 5kW PEFC system, performance of a cell was improved through successive tests of single cell of small and large area. Fabrication of three 2,5 kW class stacks, design and fabrication of natural gas reformer, design of auxiliary equipments such as DC/DC converter, DC/AC inverter and humidifying units were carried out along with integration of components, operation and evaluation of total system. During the development period from 1999 to 2001, MEA(membrane electrode assembly) fabrication technologies, design and fabrication technologies for separators, stacking technologies and so on were developed, thereby providing basis for developing stacks of higher efficiency and power density in the future. Experience of development of natural gas reformer opened possibilities to use various kinds of fuels. Main results obtained from the development of a 5kW class PEFC system for residential application are summarized.

High Efficiency Power Conversion System of Non Isolated Type Applied in Fuel Cell Generator Used to Fire Prevention Installation (소방 방재설비용 연료전지 발전시스템의 비절연형 고효율 전력변환기 설계)

  • Kwak, Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.3 s.40
    • /
    • pp.19-26
    • /
    • 2006
  • In this paper, author proposes to a fuel cell generation system used to fire prevention installation at emergency. The proposed system is used with a power source of fire prevention installation in preparation for breaking of commercial power supply at emergency. A part of most power loss of the fuel cell generation system is power converter. And the major losses of power converter are switching losses of power semiconductor switches used to power conversion. This parer is designed with a high efficiency power converter of non isolated type in order to increase efficiency of fuel cell power system. The controlling switches used in power conversion system are operated with soft switching, which is applied to partial resonant method to reduce switching loss. The result is that the fuel cell power system gets to high efficiency. Some computer simulated results and experimental results are confirmed to the validity of the analytical results.

  • PDF

Thermodynamic analysis of a combined gas turbine power plant with a solid oxide fuel cell for marine applications

  • Welaya, Yousri M.A.;Mosleh, M.;Ammar, Nader R.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.5 no.4
    • /
    • pp.529-545
    • /
    • 2013
  • Strong restrictions on emissions from marine power plants (particularly $SO_x$, $NO_x$) will probably be adopted in the near future. In this paper, a combined solid oxide fuel cell (SOFC) and gas turbine fuelled by natural gas is proposed as an attractive option to limit the environmental impact of the marine sector. It includes a study of a heat-recovery system for 18 MW SOFC fuelled by natural gas, to provide the electric power demand onboard commercial vessels. Feasible heat-recovery systems are investigated, taking into account different operating conditions of the combined system. Two types of SOFC are considered, tubular and planar SOFCs, operated with either natural gas or hydrogen fuels. This paper includes a detailed thermodynamic analysis for the combined system. Mass and energy balances are performed, not only for the whole plant but also for each individual component, in order to evaluate the thermal efficiency of the combined cycle. In addition, the effect of using natural gas as a fuel on the fuel cell voltage and performance is investigated. It is found that a high overall efficiency approaching 70% may be achieved with an optimum configuration using SOFC system under pressure. The hybrid system would also reduce emissions, fuel consumption, and improve the total system efficiency.