• 제목/요약/키워드: Fuel Nozzle

검색결과 625건 처리시간 0.019초

수소 저장용 탱크의 튜브 형상에 따른 온도분포 특성에 대한 수치해석 연구 (A Study on the Characteristics of Temperature Distribution Related to Geometry of Tube in Hydrogen Storage Vessel)

  • 오승준;윤정환;전경숙;김재규;박준홍;최정주
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.205-211
    • /
    • 2021
  • Recently, it is necessary for study on renewable energy due to environmental pollution and fossil fuel depletion. Therefore, in this study, the filling temperature according to the nozzle geometry was evaluated based on the limit temperature specified in SAEJ2601 for charging hydrogen, a new energy. There are three types of nozzles, normal, angle and round, fixed the average pressure ramp rate at 52.5 MPa/min, and the injection temperature was set at 293.4 K. As a result, the lowest temperature distribution was found in the round type, although the final temperature did not differ significantly in the three types of nozzles. In addition, Pearson's coefficient was calculated to correlate the mass flow rate with the heat transfer rate at the inner liner wall, which resulted in a strong linear relationship of 0.98 or higher.

고온 재료 테스트를 위한 고속 산소 연료 토치 흐름에서의 열유속 측정 (Heat Flux Measurements in High Velocity Oxygen-Fuel Torch Flow for Testing High Thermal Materials)

  • ;최성만;홍성민
    • 한국추진공학회지
    • /
    • 제25권2호
    • /
    • pp.34-41
    • /
    • 2021
  • 상업용 HVOF 토치 (원래 코팅 용도로 설계됨)가 재료 테스트를 위한 고온 유동원으로 수정되었다. 이 연구에서는 수냉식 상용 Gardon 게이지를 사용하여 노즐 출구에서 떨어진 네 위치에서 열유속을 측정하였다. 냉각수 온도 데이터는 동일한 위치에서 열량 측정 열유속 (calorimetric heat flux)을 계산하는 데 사용되었다. 두 방법의 열유속을 비교 한 결과 열량 측정 열유속이 Gardon 게이지 열유속보다 몇 배 더 높은 것으로 나타났다. 두 가지 방법 사이에 나타나는 불일치를 이해하기 위해 열량 측정방법에 대한 가설을 적용하였다. 이것은 가설에 대한 상당한 검증으로 간주될 수 있지만 적절한 수치모델을 사용하여 추가 개선이 필요하다.

반밀폐된 구획에서 발열량 변화에 따른 비정상 화재특성 (Effects of Change in Heat Release Rate on Unsteady Fire Characteristics in a Semi-Closed Compartment)

  • 황철홍
    • 한국화재소방학회논문지
    • /
    • 제26권2호
    • /
    • pp.75-83
    • /
    • 2012
  • 반밀폐된 구획에서 발열량 변화에 따른 환기부족화재의 비정상 열 및 화학적특성에 관한 실험적 연구가 수행되었다. 이를 위해 실규모 ISO 9705 표준화재실의 출입구 폭이 0.1 m로 축소되었으며, 구획 중앙에 설치된 분사노즐을 통해 헵탄 연료의 유량은 선형적으로 증가되었다. 구획 내부의 온도, 열유속, 화학종농도 그리고 발열량의 연속적 측정이 이루어졌으며, 비정상 열 및 화학적특성을 표현하기 위하여 총괄 당량비의 개념이 적용되었다. 주요 결과로서, 총괄 연소효율과 구획 내부의 국부 연소효율은 시간에 따라 매우 다른 결과를 보이며, 이론과 측정된 발열량을 통한 총괄 당량비 역시 큰 차이를 보이게 된다. 온도, 열유속 및 화학종 농도의 시간에 따른 변화는 총괄 당량비 개념를 통해 표현될 수 있었다. 구획 내부에서 CO의 농도는 총괄 당량비 2.0~3.0의 범위에서 최대값을 보이며, 보다 과농한 조건에서 점차적으로 감소되는 현상이 발견되었다. 추가로 본 실험을 통해 얻어진 반밀폐된 구획화재의 비정상 열 및 화학적 거동은 향후 현실적인 화재 모델링을 위한 검증 데이터로 활용될 수 있을 것으로 기대된다.

커먼레일 디젤인젝터의 분사성능 개선을 위한 내부유로형상 최적화에 관한 수치적 연구 (A Numerical Study on the Geometry Optimization of Internal Flow Passage in the Common-rail Diesel Injector for Improving Injection Performance)

  • 문성준;정수진;이상인;김태훈
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.91-99
    • /
    • 2014
  • The common-rail injectors are the most critical component of the CRDI diesel engines that dominantly affect engine performances through high pressure injection with exact control. Thus, from now on the advanced combustion technologies for common-rail diesel injection engine require high performance fuel injectors. Accordingly, the previous studies on the numerical and experimental analysis of the diesel injector have focused on a optimum geometry to induce proper injection rate. In this study, computational predictions of performance of the diesel injector have been performed to evaluate internal flow characteristics for various needle lift and the spray pattern at the nozzle exit. To our knowledge, three-dimensional computational fluid dynamics (CFD) model of the internal flow passage of an entire injector duct including injection and return routes has never been studied. In this study, major design parameters concerning internal routes in the injector are optimized by using a CFD analysis and Response Surface Method (RSM). The computational prediction of the internal flow characteristics of the common-rail diesel injector was carried out by using STAR-CCM+7.06 code. In this work, computations were carried out under the assumption that the internal flow passage is a steady-state condition at the maximum needle lift. The design parameters are optimized by using the L16 orthogonal array and polynomial regression, local-approximation characteristics of RSM. Meanwhile, the optimum values are confirmed to be valid in 95% confidence and 5% significance level through analysis of variance (ANOVA). In addition, optimal design and prototype design were confirmed by calculating the injection quantities, resulting in the improvement of the injection performance by more than 54%.

반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가 (Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room)

  • 문선여;황철홍
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.21-28
    • /
    • 2012
  • 비정상(unsteady) 화재성장이 발생되는 반밀폐된 구획에서 환기부족화재의 열 및 화학적 특성에 관한 FDS(Fire Dynamics Simulator)의 예측성능 평가가 수행되었다. 이를 위해 실규모 ISO 9705 표준 화재실의 출입구 폭이 0.1 m로 축소되었으며, spray 노즐을 통해 Heptane 연료유량은 선형적으로 증가되었다. 수치계산에 대한 신뢰도 확보를 위하여 동일 조건에서 수행된 실험결과와의 상세한 비교가 이루어졌다. 적절한 격자계를 이용한 FDS의 결과는 구획 내부의 온도 및 열유속(heat flux)은 비교적 잘 예측하지만, 비정상 CO 및 $CO_2$ 생성특성은 적절히 예측하지 못함을 확인하였다. 이러한 결과는 최근 수행된 유사조건의 정상상태 환기부족 구획화재에 대한 FDS 예측결과와 상반된 것으로서, 반밀폐된 구획화재 모델링에서 FDS를 이용한 비정상 CO 생성특성 예측에 상당한 주위가 요구됨을 확인하였다.