• 제목/요약/키워드: Fuel NOx

검색결과 934건 처리시간 0.024초

자동차 오염물질 배출계수 산정을 위한 CVS-75모드와 국내차속모드의 상관성 비교 연구 (Comparison of Correlation between CVS-75 Mode and Korea Mode to Estimate Emission Factors from Vehicles)

  • 정성운;류정호;유영숙
    • 한국대기환경학회지
    • /
    • 제22권3호
    • /
    • pp.383-391
    • /
    • 2006
  • In Korea, the major source of serious air pollution is motor vehicles. Air pollution from vehicles has been annually increased. Then the government will try to control the vehicle emission by applying the effective emission management policy for the manufactured and in-used car. It is necessary to correctly calculate the emission factor for successful propulsion of the vehicle emission control policy. In this study, correlation analysis of exhaust emissions from vehicles between CVS-75 mode and Korea mode was conducted. A total of 25 light-duty buses were tested on the chassis dynamometer system in order to measure CO, HC, NOx PM and fuel efficiency (F.E.). For the test modes, 10 different Korea modes and CVS-75 mode were used. As the result of correlation analysis between those modes, most of the correlation coefficients were higher than 0.90. On the basis of high correlation between those modes, correction factors by driving conditions were estimated. Through the results of this study, we obtained essential basic data to correct difference from those modes.

HANJUNG 석탄 실험연소로의 초기운전 (The First Operation of Coal Combustion Test Facility in HANJUNG)

  • 장길홍;장인갑;정석용;천무환;김중석
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1998년도 제17회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.79-84
    • /
    • 1998
  • In this paper we show design and operation of 1MWth pulverized coal combustion test facility. The test facility is consists of coal feeding system, furnace and flue gas treatment system. The furnace is equipped with a top-fired burner in order to avoid influence of gravity on the coal particles. There are two part of vertical(VP) and horizontal pass(HP) at furnace. We can measure temperature and species of coal flames in vertical pass. Also, there is horizontally arranged section where investigation regarding corrosion and deposit formation will be carried out. The burner of combustor was externally air staging burner(EASB) type made by IFRF. The pulverized high bituminous(Blair athol) coal from Australia was used as fuel, and the particle size less than 80 ${\mu}m$ was 83.4%. Overall excess air ratio was 1.2.

  • PDF

가스엔진과 디젤엔진의 혼합 EGR시스템이 배기배출물에 미치는 영향 (Effects on Exhaust Gas Emission in Combined EGR System of Gas Engine and Diesel Engine)

  • 유동훈;서전수신;임재근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.896-902
    • /
    • 2009
  • EGR is applied in order to lower temperature of combustion chamber by using the specific heat of carbon dioxide in engine exhaust gas. However, the problem of EGR system in diesel engine is high PM concentration. Combined EGR system can be reduced it by mixing exhaust gas of gas engine into the intake air of diesel engine. This experimental study was designed for EGR system for both engines use. The results of EGR experimental study by using diesel engine and gas engine are as follows. 1) The pressure of combustion and rate of heat release decreased. 2) The specific fuel consumption increased. But, up to middle load, it little increased. 3) NO concentration has decreased up to 50% in almost all combustion area. 4) The variation of the PM concentration at low load is not so seen. But at high load, PM increased rapidly when concentration of oxygen is decreased and most of it caused the increasing of Dry Soot.

자트로파 유(Crude Jatropha Oil)에 대한 보일러 직접 연소 특성 (Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler)

  • 강새별;김종진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2934-2939
    • /
    • 2008
  • We conducted a test of a direct burning of crude Jatropha oil (CJO) in a commercial boiler system. The fuel, crude Jatropha oil is not biodiesel which comes from transeterification process of bio oil, but it is pure plant oil. The higher heating value (HHV) of the CJO is 39.3 MJ/kg (9,380 kcal/kg) and is higher than that of a commercial heating oil, 37.9 MJ/kg. The kinematic viscosity of CJO is 36.2 mm2/s at $40^{\circ}C$ and 8.0 mm2/s at $100^{\circ}C$. The burner used in the test is a commercial burner for a commercial heatingoil and its capacity is 140 kW (120,000 kcal/h). We did a preliminary test whether the combustion is stable or not. The preliminary test was a kind of open air combustion test using the commercial burner with crude Jatropha oil. We found that the combustion can be stable if the crude Jatrophaoil temperature is higher than $90^{\circ}C$. We measured the flue gas concentration by using a gas analyzer. The NOx concentration is $80{\sim}100\;ppm$ and CO concentration is nearly 0 ppm at flue gas O2 concentration of 3.0 and 4.5%.

  • PDF

난류발생기가 장착된 선회기를 이용한 연소기내의 혼합 및 연소 특성 (The Characteristics of Mixing and Combustion in the Combustor with Turbulence Generator)

  • 류승협;서정무;박용국;이근선;문수연;이충원
    • 한국추진공학회지
    • /
    • 제5권4호
    • /
    • pp.83-93
    • /
    • 2001
  • 본 연구에서는 화염의 안정화를 위하여 사용되는 선회류 발생 장치의 베인에 작은 스케일의 난류를 발생시킬 수 있는 난류 발생기를 장착하여 연료와 흡입공기의 혼합을 촉진시키고, 연소와 온도의 균일도를 향상시키기 의한 실험적 검토를 행하였다. 실험에서는 내부 혼합용 이유체 분사노즐 사용하여 등유를 분사시킨 후 연료와 흡입공기의 혼합과 연소 현상을 관측하였다. 난류발생기는 베인 각도에 따른 베인과 베인 사이의 각 단면의 면적을 계산하여 그 유로단면의 면적에 대한 비율로서 난류발생기의 면적을 결정하여 선회기를 통과하는 유로 단면적의 각각 0%, 3%, 7%, 12%에 해당하는 면적의 난류 발생기를 제작하여 선회기 출구 베인의 끝단에 설치하였다. 실용 연소기의 구조를 어느 정도 단순화한 환형 연소기에서의 농도분포, 화염구조 및 온도분포를 조사하여 효과적인 연소기내의 연소제어에 사용하고자 한다.

  • PDF

커먼레일 디젤기관에서 분사전략에 따른 성능 및 배출가스에 관한 연구 (A Study on Characteristics of Performance and Emission by CRDI Engine's Injection Strategy)

  • 엄동섭;고동균;나완용;이성욱
    • 한국분무공학회지
    • /
    • 제16권3호
    • /
    • pp.134-139
    • /
    • 2011
  • Recent research has focused on engine combustion technology as well as application of after-treatment in order to comply with emission regulation. However, it is much more efficient way to control emissions from engine itself and furthermore research on engine control will provide the direction of after-treatment technology in future. Furthermore, emission standard regulation for passenger diesel vehicles has been stringent compared to others and nano-particles will be included in EURO6 regulation in Europe and similar emission standard will be introduced in Korea. A 3.0 liter high speed diesel engine equipped with by CRDI system of 160MPa injection pressure, and an intake/exhaust system of V type 6 cylinder turbo-intercooler was applied. The injection duration and injection quantity, pilot injection types which are related to CRDI and air/fuel ratio control applied by EVGT were changed simultaneously. Standard experiment procedure constituted dilution apparatus and CPC system to collect nano-particles and these test results were compared with regulated materials of CO, HC, NOx and investigated their relations and characteristics of nano-particles.

연소효율 개선을 위한 스월제트의 난류유동 특성에 관한 연구 (A Study on the Turbulent Flow Characteristics of Swirl Jets for Improvement of Combustion Efficiency)

  • 고동국;윤석주
    • 한국분무공학회지
    • /
    • 제19권2호
    • /
    • pp.75-81
    • /
    • 2014
  • Swirl flow in the gun type burner has a decisive effect on the stabilization of the flame, improvement of the combustion efficiency, and also a reduction of NOx. This swirl flow is created by the spinner which is inside the airtube that guide the combustion air. Gun type burner has generally the inner devices composed nozzle adapter, spark gap ignitor, and spinner. These inner components change the air flow behavior passing through air tube. Meanwhile, turbulent characteristics of this air flow are important to understand the combustion phenomena in the gun type burner, because the mixture of fuel and air are depended on. However, nearly all of the studies have been analyzed the turbulent flow of simplified combustion formation without the inner devices. So, this study conducted the measurement using by hot-wire anemometer and analyzed turbulent flow characteristics of the swirl flow discharged from the air tube with inner devices. Turbulence characteristics come up in this study were turbulence intensity, kinetic energy and shear stress of the air flow with the change of the distance of axial direction from the exit of the air tube.

Emissions in lean-lean two-stage combustion using premixed tubular flames

  • Takagi, Hideyuki;Hayashi, Shigeru;Yamada, Hideshi;Kawakami, Tadashige
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.466-471
    • /
    • 2004
  • In gas turbines, excess air for combustion is available and therefore lean premixed combustion is the most promising approach to the significant reduction of thermal NOx emissions. At lean conditions, however, flame stability is inherently worse and hence combustion tends to be incomplete. Efforts have been devoted toward extending the operating range of complete combustion at leaner conditions. One of them is the lean-lean two-stage combustion where lean to ultra-lean secondary mixtures are mixed with the hot burned gas from the primary stage. Conventional flame combustion or flameless reaction are initiated depending on the conditions of the secondary zone. In the first part of the present study, the effects of fuel injection on the emissions and flame stability were investigated for a single tubular flame, In the second part, the emissions and flame stability were studied for a two-stage combustor with secondary mixture injected through the tangential slots on a cylindrical combustor wall. The effects of the ratio of air flow rates to the primary and secondary zones on the emissions and combustion characteristics were investigate.

  • PDF

열병합발전소 배기 덕트 시스템의 소음 진동 저감 (Noise and vibration reductions in exhaust duct system of cogeneration power plants)

  • 김원현;주원호;배종국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.641-646
    • /
    • 2004
  • Noise and vibration was encountered in exhaust duct system which is connected with a gas turbine and a heat recovery steam generator(HRSG) of a cogeneration power plants. Especially, these problems occurred when water was added to the fuel injection to reduce NOx contents of the exhaust gas. Through the cavity mode analysis and measurements, It was concluded that these problems occurred due to the acoustic resonance between the duct cavity mode and the excitation force induced by turbulent gas flow during water injection. To reduce the noise and vibration, optimal baffle plate to change the cavity mode was installed inside of duct and noise levels of about 8 dB(A) are reduced in duct system. The effects of baffle plate and guide vane to the HRSG or inlet duct vibration were also evaluated and it was verified that there is no relation to the resonance phenomena. So, vibration of inlet duct was easily reduced by the reinforcement of structures.

  • PDF

환경에너지시설내 화격자식 소각로 수치해석 연구 (Numerical research for Gate Type Waste Incinerators In Environment energy facilities)

  • 김종윤;전용한
    • 대한안전경영과학회지
    • /
    • 제19권4호
    • /
    • pp.149-155
    • /
    • 2017
  • This study is analyzed combustion phenomena based on the environmental energy facility incinerator. It is assumed that combustible components of waste are composed of carbon and hydrogen, and the combustion process of fuel is by setting as multi-component / multistage reaction. As the combustion chamber is burned, the high temperature environment is achieved, also the heat transfer accompanied by the turbulent flow and the generation of NOx, a pollutant, are interpreted to predict the thermal and fluid characteristics and pollution emissions of the grate incinerator. As the result of internal flow analysis, the slow flow around the ash chute and the mixing effect due to the complicated turbulence around the combustion chamber were predicted to show excellent performance. It is shown to the internal average temperature was about $1024^{\circ}C$, around the about $1000^{\circ}C$ homogeneous temperature distribution. Due to the sudden temperature decrease in the boiler, the flue gas temperature at the outlet was estimated to be about $220^{\circ}C$.