A Study on the Comparison of Measurement and Prediction of Underground Temperature in Gumi. (구미지역 지중온도의 실측과 예측에 관한 비교 연구)

  • Jeong sooill
    • Journal of the Korean housing association
    • /
    • v.15 no.4
    • /
    • pp.99-105
    • /
    • 2004
  • Korea gets most of its housing energy from fossil fuel which can be mined only for 30 years. So the development of an alternative energy is very important. Solar and underground thermal energy are two of these alternatives but little study has been conducted on these. For use of underground energy, we need accurate data regarding underground temperature, but there are only 30 measuring points for underground temperature in the entire country. We need to have a method of predicting underground temperature precisely. In this study the underground temperature is measured at under 3m in Gumi, and these data are compared with predicted data for checking the accuracy of the predicting method.

A Study on the Measurement of Individual Spray Cone Angle from Gasoline Direct Injection Injector using Spray Pattern Analysis (분무패턴 분석을 이용한 가솔린 직접 분사식 인젝터의 개별 분무플럼 분무각 측정 방법에 대한 연구)

  • Park, Jeonghyun;Cho, Hanbin;Park, Suhan
    • Journal of ILASS-Korea
    • /
    • v.25 no.2
    • /
    • pp.51-59
    • /
    • 2020
  • The purpose of this study is to propose and compare methods for measuring individual spray cone angles using spray cross-section images. In direct injection gasoline engines, it was believed that the distribution of air-fuel mixture in the combustion chamber directly affected combustion performance and emission formation. However, since gasoline direct injection (GDI) injectors have a small injection angle, interference between individual spray plumes occurs. Therefore, GDI injectors have only measured the spray angle of the entire spray. To overcome these limitations, three methods of indirectly measuring the spray cone angles of individual spray plume were presented and compared by forming sheet beams using Nd:YAG laser and acquiring spray cross-section images. Each method currently has advantages and disadvantages, and research to apply the method suitable for various GDI injectors needs to be continued.

System Configuration of Ultrasonic Nuclear Fuel Cleaner and Quantitative Weight Measurement of Removed CRUD (초음파 핵연료 세정장비의 시스템 구성과 제거된 크러드의 정량적 무게 측정법)

  • Jung Cheol Shin;Hak Yun Lee;Un Hak Seong;Yeong Jong Joo;Yong Chan Kim;Wook Jin Han
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • Crud is a corrosion deposit that forms in equipments and piping of nuclear reactor's primary systems. When crud circulates through the reactor's primary system coolant and adheres to the surface of the nuclear fuel cladding tube, it can lead to the Axial Offset Anomaly (AOA) phenomenon. This occurrence is known to potentially reduce the output of a nuclear power plant or to necessitate an early shutdown. Consequently, worldwide nuclear power plants have employed ultrasonic cleaning methods since 2000 to mitigate crud deposition, ensuring stable operation and economic efficiency. This paper details the system configuration of ultrasonic nuclear fuel cleaning equipment, outlining the function of each component. The objective is to contribute to the local domestic production of ultrasonic nuclear fuel cleaning equipment. Additionally, the paper introduces a method for accurately measuring the weight of removed crud, a crucial factor in assessing cleaning effectiveness and providing input data for the BOA code used in core safety evaluations. Accurate measurement of highly radioactive filters containing crud is essential, and weighing them underwater is a common practice. However, the buoyancy effect during underwater weighing may lead to an overestimation of the collected crud's weight. To address this issue, the paper proposes a formula correcting for buoyancy errors, enhancing measurement accuracy. This improved weight measurement method, accounting for buoyancy effects in water, is expected to facilitate the quantitative assessment of filter weights generated during chemical decontamination and system operations in nuclear power plants.

Technology of Fuel cell stack fault detection by THDA (전고조파 왜율 분석을 통한 연료전지 스택 고장진단 기술)

  • Kim, UckSoo;Park, HyunSeok;Kang, SunDoo;Eom, JeongYong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.90.1-90.1
    • /
    • 2011
  • This technology is applicable to Electrical vehicle that using Energy from Hydrogen Fueled Cell. Electricity & water is got from chemical reaction between H2 & O2 in stack. This technology is used when fault diagnosis of Fuel cell is needed. It is General method that measure each cell's voltage of stack for fault diagnosis. but, this technology is method of measuring entire voltage of stack. For this reason, fault diagnosis system is simplified and cost of system is lower than previous one. In normal stack condition, characteristic graph of voltage-current has linearity. In fault stack condition, it has non-linearity. we use this characteristic to diagnosis of stack fault. In this technology, Specific frequency current is injected into stack & Stack voltage is measured in response. After that, stack voltage difference is analyzed to diagnosis of stack fault. Presently, Development of current injection module & basic program of THDA is finished. in future we will develop the technology of precise measurement technology about entire stack voltage.

  • PDF

Study on Ohmic Resistance of Polymer Electrolyte Fuel Cells Using Current Interruption Method (전류차단법을 이용한 고분자전해질 연료전지의 오믹 저항 연구)

  • Ji, Sanghoon;Hwang, Yong-Sheen;Lee, Yoon Ho;Park, Taehyun;Paek, Jun Yeol;Chang, Ikwhang;Cha, Suk Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.353-358
    • /
    • 2013
  • The current interruption method is considered to be an efficient way of measuring the resistance of a fuel cell. In this study, the ohmic area specific resistances (ASRs) of polymer electrolyte fuel cells with different types of bipolar plates were evaluated using the current interruption method. The ohmic ASRs of both a fuel cell with graphite bipolar plates and a fuel cell with graphite foil-based assembled bipolar plates decreased as the current density increased. On the other hand, with increasing cell temperature, the ohmic ASRs of a fuel cell with graphite bipolar plates were decreased by a reduction in the proton transport resistance through the membrane, and the ohmic ASRs of a fuel cell with graphite foil-based assembled bipolar plates were increased by the differences in thermal expansion between different components of the bipolar plates.

Development of Real-time Diagnosis Method for PEMFC Stack via Intermodulation Method (Intermodulation 방법에 의한 자동차용 연료전지 스택의 실시간 진단방법 개발)

  • Lee, Young-Hyun;Yoo, Seungyeol;Kim, Jonghyeon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.7
    • /
    • pp.76-83
    • /
    • 2014
  • During PEMFC(Proton Exchange Membrane Fuel Cell) operation monitoring and diagnosis are important issues for reliability and durability. Stack defect can be followed by a critical cell voltage drop in the stack. One method for monitoring the cell voltage is CVM(Cell Voltage Monitoring), where all cells in the stack are electrically connected to a voltage measuring system and monitored these voltages. The other methods are based on the EIS(Electrochemical Impedance Spectroscopy) and on nonlinear frequency response. In this paper, intermodulation(IM) method for diagnosis PEMFC stack is introduced. To detect one or more critical PEMFC cell voltage PEMFC stack is excited by two or more test sinusoid current, and the frequency response of the stack voltage is analyzed. If one or more critical cell voltage exists, higher harmonics on the voltage frequency spectrum will appear. For the proposed IM method, stack simulation and experiments are conducted.

Thickness measurements of a Cr coating deposited on Zr-Nb alloy plates using an ECT pancake sensor

  • Jeong Won Park;Bonggyu Ji;Daegyun Ko;Hun Jang;Wonjae Choi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3260-3267
    • /
    • 2023
  • Zr-Nb alloy have been widely used as fuel rods in nuclear power plants. However, from the Fukushima nuclear accident, the weakness of the rod was revealed under harsh conditions, and research on the safety of these types of rods was conducted after the disaster. The method of depositing chromium onto the existing Zr-Nb alloy fuel rods is being considered as a means by which to compensate for the weakness of Zr-Nb alloy rods because chromium is strong against oxidation at high temperatures and has high strength. In order to secure these advantages, it is important to maintain the Cr thickness of the rods and properly inspect the rods before and during their use in power generation. Eddy current testing is a typical means of evaluating the thickness of thin metals and detecting surface defects. Depending on the size and shape of the inspected object, various eddy current sensors can be applied. In particular, because pancake sensors can be manufactured in very small sizes, they can be used for inspections even in narrow spaces, such as a nuclear fuel assembly. In this study, an eddy current technique was developed to confirm the feasibility of Cr coating thickness evaluations. After determining the design parameters of the pancake sensor by means of a FEM simulation, a FPCB pancake sensor was manufactured and the optimal frequency was selected by measuring minute changes in the Cr-coating thickness using the developed sensor.

New Ignition Method and Ignition Recognition Logic for a Microturbine (마이크로터빈의 새로운 점화 기법과 점화 인식 로직 개발)

  • Kim, Gi-Rae;Choi, Young-Kyu;Rho, Min-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.179-186
    • /
    • 2007
  • This paper presents new ignition method and ignition recognition logic for a microturbine. New ignition method is designed by constant speed control of a microturbine with pre-determined time during a ignition period. It make more accurate air-fuel ratio as well as give enough time to ignition system to have full performance under cold temperature. And ignition recognition logic is designed by observing output current change of inverter by generating output torque of a microturbine in the instant of ignition. For filtering a output torque current of inverter with high frequency, we applied a moving average method. So far, ignition recognition is usually implemented by measuring of exhausted gas temperature(EGT) of microturbine. The proposed logic can give more accurate judgement of ignition as well as keep a good working of starting system under out of order a temperature measuring system and biased initial value of EGT sensor. Finally, the two proposed logics are proved by field operating a microturbine under various conditions.

A Study on In-Cylinder Measurement of Flame Temperature and Soot Distribution in D.I. Diesel Engine Using Tow-Color Method (이색법을 이용한 직접 분사식 디젤엔진 실린더내의 화염 분도 및 Soot 분포 측정에 관한 연구)

  • 박정규;정수훈;원영호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.42-53
    • /
    • 1999
  • Two dimensional flame temperature and KL value distribution from the luminous flame containing soot in a DI diesel engine were measured by the tow-color method using tow different wavelengths of the flame image. The combustion chamber of a DI diesel engine was visualized by elongating the piston and cylinder and the flame in the combustion chamber was photographed on a nega-color film using a high speed camera. In this study, color CCD camera was used to digitize the three color density of the film exposed to the flame and standard lamp . The accuracy of the measuring method depends on the calibration line of film made from a high temperature standard tungsten lamp. The formation and oxidization of soot in the diesel engine were studied by observing measured time history of KL factor and flame temperature . Also , effects of various shapes of combustion chamber and fuel injection on flame temperature. Also, effects of various shapes of combustion chamber and fuel injection on flame temperature and KL value distribution were examined.

  • PDF

A Study on Droplet Distribution of Bio Diesel Fuels Using Immersion Sampling Method (액침법에 의한 바이오디젤유의 액적분포에 관한 연구)

  • Kim, M.S.;Doh, H.C.;Koh, D.K.;Ahn, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.5-10
    • /
    • 2006
  • The purpose of this study is to measure the droplet distribution and Sauter mean diameter(SMD) of biodiesel fuel, using the immersion sampling method. This method involves using an optical microscope and a CCD camera, to take an image of the droplets. These images are then measured by using a 'Sigma Scan' processing program. The results of the above experiment are summarized as followed ; (1) There can be as much as a 10% error rate when measuring the diameter of these droplets, using the image processing method and the naked eye. (2) The result of droplet size distribution test, TVO(transesterified vegetable oil) big size droplet distribution were increased at ambient pressure $6kg/cm^2$. (3) When ambient pressure increased $6kg/cm^2$ above, SMD variation of TVO and UVO(used vegetable oil) 30 are small. (4) On Rosin-Rammler analysis, droplets size distribution of UVO(used vegetable oil) 30 uniform more than TVO 20 on ambient pressure $1kg/cm^2$.

  • PDF