• Title/Summary/Keyword: Fuel Droplet

Search Result 360, Processing Time 0.023 seconds

Characterization of the internal flow and fuel spray from an impinging flow nozzle (노즐분공내 유체충돌이 있는 디젤노즐의 유동 및 분무특성 연구)

  • Ha, Seong-Eop;Kim, Heung-Yeol;Gu, Ja-Ye;Ryu, Gu-Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.12
    • /
    • pp.1635-1646
    • /
    • 1997
  • The nozzle length to diameter ratio of real diesel nozzles is about 2-8 which is not long enough for a fully developed and stabilized flow. The characteristics of the flow such as turbulence at the nozzle exit which affect the development of the spray can be enhanced by impinging the flow inside nozzle. The flow details inside the impinging nozzles have been investigated both experimentally and numerically. The mean velocities, the fluctuating velocities, and discharge coefficients in the impinging inlet nozzles, round inlet nozzle, and sharp inlet nozzle were obtained at various Reynolds number. The developing feature of the external spray were photographed by still camera and the droplet sizes and velocities were also measured by laser Doppler technique. The spray angle was greater and the droplet sizes near the spray axis were smaller with the impinging flow inside nozzle.

Combustion and Microexplosion of Al/Liquid Fuel Slurry Droplets(I)-Ewperimental Study- (Al/액체연료 슬러리 액적의 연소와 (1)-실험적 연구-)

  • Byeon, Do-Yeong;Jo, Ju-Hyeong;An, Guk-Yeong;Baek, Seung-Uk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.12
    • /
    • pp.1576-1585
    • /
    • 1997
  • The microexplosive combustion of a slurry droplet was investigated experimentally. The microexplosion has been approximately considered to be caused by pressure build-up in the shell and to be promoted by heterogeneous nucleation of liquid carrier, which is due to the suppression of evaporation and subsequent superheating of liquid carrier. To closely investigate the pressure build-up and the heterogeneous nucleation, the experiments were conducted in an electric combustor, of which temperature was controllable (400 K-900 K). And the effects of two aligned droplets on the interactive combustion and microexplosion were found in a hot post region of a flat flame burner. Transient internal temperature distributions for slurry droplets were measured. And the shell formation and the microexplosion of suspended A1/JP-8 and Al/n-heptane slurry droplets were examined with various surfactant concentrations (0.5-5 wt%) and solid loadings (10-50 wt.%). The microexplosion time of binary array of droplets was found to be less than that of the isolated droplet due to radiative interaction between droplets.

Atomization Characteristics of Three Types of Swirl Injectors (세 가지 유형 와류 분사기들의 미립화 특성)

  • Hadong Jung;Jonghyeon Ahn;Kyubok Ahn
    • Journal of ILASS-Korea
    • /
    • v.28 no.2
    • /
    • pp.75-88
    • /
    • 2023
  • In this paper, the atomization characteristics of bi-swirl coaxial injectors for a 420 N-class bipropellant thruster were investigated. Three types of injectors, namely closed-type, open-type, and screw-type, were manufactured and designed to have the same spray angle and injection pressure drop. Water was used as a simulant, and cold-flow tests were conducted under ambient temperature and pressure conditions. Since the inner and outer injectors were designed to be the same type, only the inner fuel injectors that were easy to measure were used. Using a phase doppler particle analyzer, the velocity and diameter of atomized droplets were measured. Closed-type swirl injector exhibited droplet distributions with relatively high velocities and small SMD compared to the other two injectors. Open-type swirl injector formed droplets with reverse velocities in the center region and had a large recirculation zone. Screw-type swirl injector showed a sharp decrease in droplet velocity and size with radial distance from the liquid film breakup point. For the same design requirements, the closed-type swirl injector has superior atomization performance.

A Study of Improving Fuel Droplet Movement with Sonic Wave Radiation (음파를 이용한 연료 입자 운동성 향상에 관한 연구)

  • Min, Sunki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.608-613
    • /
    • 2019
  • NOx (Nitrogen oxide) in the exhaust gas from vehicle engines is considered one of the most harmful substances in air pollution problems. NOx is made when combustion occurs under high temperature conditions and EGR (exhaust gas recirculation) is normally used to lower the combustion temperature. As the EGR ratio increases, the NOx level becomes low, but a high EGR ratio makes the combustion unstable and causes further air pollution problems, such as CO and unburned hydrocarbon level increase. This study showed that fuel droplets could move more freely by the radiation of sonic wave for the stable combustion. In addition, the engine performance improved with increasing EGR ratio. As a basic study, the effect of sonic wave radiation on the velocity of fuel droplets was studied using CFD software. The results showed that the velocity of small droplets increased more under high frequency sonic wave conditions and the velocity of the large droplets increased at low frequency sonic wave conditions. In addition, an engine analysis model was used to study the effects of the increased combustion stability. These results showed that a 15% increase in EGR ratio in combustion resulted in a 45% decrease in NOx and a 10% increase in thermal efficiency.

A Study on the Characteristic and Droplet Uniformity of Spray Injection to Exhaust Gas Flow from Urea Solution Injector (Urea 수용액의 배기가스 유동장내 분무 특성과 분무 균일도에 관한 연구)

  • Oh, Jung-Mo;Cha, Won-Sim;Kim, Ki-Bum;Lee, Jin-Ha;Lee, Ki-Hyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.3
    • /
    • pp.83-89
    • /
    • 2011
  • Diesel engines can produce higher fuel efficiency and lower $CO_2$ emission, they are subject to ever more stringent emission regulation. However, there are two major emission concerns fo diesel engines like such as particulate matter (PM) and nitrogen oxides (NOx). Moreover, it is not easy to satisfy the regulations on the emission of NOx and PM, which are getting more strengthened. One of the solutions is to apply the new combustion concept using multistage injection such as HCCI and PCCI. The other solution is to apply after-treatment systems. For example, lean NOx trap catalyst, Urea-SCR and others have various advantages and disadvantages Especially, Urea-SCR system have advantages such as a high conversion efficiency and a wide operation conditions. Hence the key factor to implementation of Urea-SCR technology, good mixing of urea(Ammonia) and gas, reducing Ammonia slip. Urea mixer components are required to facilitate evaporation and mixing because the liquid state of urea poses significant barriers for evaporation, and the distance to mixer is the most critical that affect mixer performance. In this study, to find out the distance from injector to mixer and simulation factor, a laser diagnostics and high speed camera are used to analyze urea injector spray characteristics and to present a distribution of urea solution in transparent manifold In addition, Droplet Uniformity Index is calculated from the acquired images by using image processing method to clarify the distribution of spray.

A Study on the Extinguishing Performance of Water Mist with Additives (첨가제가 혼합된 미세물분무의 소화성능에 관한 연구)

  • 이경덕;신창섭
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Halogen-based fire suppressing agents have environmental problems because they cause the stratospheric ozone depletion and globe warming. Hence, fire suppression system using fine water mist became the center of interest as a substitution of halon. As a study about this, it is in progress to make the optimum droplet size by using water mist nozzles and to improve the extinguishing performance of water mist by using additives. Before this study, the extinguishing time of ethanol and n-heptane pool fire was measured with changing of water mist droplet size, flow density, discharge pressure, and fire size. In this study, on adding the additives to improve physical and chemical extinguishing performance of water mist, the extinguishing performance would evaluate and the optimum condition would find out. As a result, in case of ethanol pan 1 pool fire, the extinguishing time of the water mist by adding of 2.5 wt% NaCl and 0.3% AFFF got shorter 27% and 60% than the pure water mist. Adding of AFFF was to decrease the flame temperature by forming thin film on the fuel surface and to decrease the evaporation of n-heptane fuel. In case of NaCl, alkali salt crystals showed on the flame surface.

Basic Study of Spray-Behavior Characteristics of Emulsified Fuel (에멀젼연료의 분무거동특성에 관한 기초연구)

  • Yeom, Jeong Kuk;Yoon, Jeong Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.763-771
    • /
    • 2014
  • As a preliminary study on the spray behavior characteristics of emulsified fuel, the fuel properties (viscosity, surface tension, and density) and evaporation characteristics of a fuel droplet were investigated. The emulsified fuel was made by mixing diesel and $H_2O_2$. In addition, the macroscopic spray behavior characteristics such as the spray penetrations and spray angles of the emulsified and diesel fuels were compared. The stirring condition of the emulsified fuel was a 9:1 mixture of the diesel fuel and the surfactant span 80. The mixing ratios for the hydrogen peroxide were set at EF2, EF12, EF22, EF32, EF42, EF52, EF62, EF72, EF82, and EF92. The injection pressures were set at 400, 600, 800, and 1000 bar. We found that as the mixing ratio of the hydrogen peroxide was increased from EF2 to EF52, the viscosity of the emulsified fuel increased. However, afterward, the viscosity of the emulsified fuel gradually decreased and approached the viscosity value of the diesel fuel. Therefore, generally oil-in-water emulsions were used for the hydrogen peroxide mixing ratios up to 52 (EF52), and water-in-oil emulsions were used for the hydrogen peroxide mixing ratios above 52. Finally, the spray behavior characteristics (spray penetration and spray angle) of the emulsified fuel were found to be almost independent of the mixing ratio.

Study of Behavior Characteristics of Emulsified Fuels with Evaporative Field (증발장에서 에멀젼연료의 거동특성에 관한 연구)

  • Yeom, Jeong Kuk;Yoon, Jeong Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.237-243
    • /
    • 2015
  • In this study, the effects of the mixing ratio of emulsified fuel on the droplet evaporation and spray behavior characteristics were analyzed. A surfactant comprising span 80 and tween 80 mixed at a 9:1 ratio was used for the emulsified fuel. The fuel and surfactant were mixed at a ratio of 3:1 for the emulsified fuel. In addition, considering the mixing ratio of the surfactant, the mixing ratio of $H_2O_2$ in the emulsified fuel was set as EF (emulsified fuel)0, EF2, EF12, EF22, EF32, and EF42. To observe the evaporation characteristics, droplets of the emulsified fuel were dropped on a heating plate and observed using scattered light and a Schlieren system. In addition, to analyze the effect of the $H_2O_2$ mixing ratio, the behavior characteristics of the evaporative free spray were investigated in the mixing ratio range of EF0 to EF22 using a constant volume chamber with heaters. Consequentially, it was found that in the case of EF22, the free spray development of the emulsified fuel was faster than that of EF0 (diesel only) because of the promotion of the evaporation due to the phase change in the peroxide contained in the emulsion fuel.

Icing Characteristics in Liquid-Phase Injection of LPG Fuel (액상분사식 LPG 인젝터의 아이싱 생성 특성 및 억제 방법)

  • Lee, Sun-Youp;Kim, Chang-Up;Choi, Kyo-Nam;Kang, Kern-Yong
    • Journal of ILASS-Korea
    • /
    • v.14 no.4
    • /
    • pp.147-152
    • /
    • 2009
  • Since a liquid-phase LPG injection system allows accurate control of fuel injection and increase in volumetric efficiency, it has advantages in achieving higher engine power and lower emissions compared to the mixer type LPG supplying system. However, this system also leads to an unexpected event called icing phenomenon which occurs when moisture in the air near the injector freezes and becomes frost around the nozzle hole due to extraction of heat from surrounding caused by instant fuel vaporization. As a result, it becomes difficult to control air/fuel ratio in engine operation, inducing exacerbation of engine performance and HC emission. One effort to mitigate icing phenomenon is to attach anti-icing injection tip in the end of nozzle. Therefore, in this study, the effect of engine operation parameters as well as surrounding conditions on icing phenomenon was investigated in a bench test rig with commercially-used anti-icing injection tips. The test results show that considerable ice was deposited on the surface near the nozzle hole of the anti-icing tip in low rpm and low load operating conditions in ambient air condition. This is because acceleration of detachment of deposited ice from the tip surface was induced in high load, high rpm conditions, resulting in decrease in frost accumulation. The results of the bench testing also demonstrate that little or no ice was formed at surrounding temperature below a freezing point since the absolute amount of moisture contained in the intake air is too small in such a low temperature.

  • PDF

The Numerical Study on Effect of the Droplet Sizes on Internal Mass Transfer in the Spray Type Scrubber (분무형 스크러버에 내에서 액적크기에 따른 물질전달에 관한 전산해석적 연구)

  • Lee, Chanhyun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.19-32
    • /
    • 2019
  • As regional air pollution gets worse by the sulfur oxides emitted from various types of vessels passing through the many countries, the International Maritime Organization establishes the emission control areas and regulates sulfur dioxide in those areas. In order to satisfy these regional regulations, the fuel selection method and the exhaust gas post-treatment device are applied to the ships. Due to the economic reasons, the post-treatment method of exhaust gas for reducing the amount of sulfur oxides discharged is mainly preferred. The scrubber which is dominantly used in the ships are the spray type system where the sprayed liquid drops used for capturing the soluble sulfur dioxides in the exhaust gas. The performance of the spray type system depends on the size distribution of the sprayed droplets. In order to evaluate this performance, we designed counterflow type scrubber and cyclone scrubber and evaluated the desulfurization efficiency and the amount of droplet evaporation according to the size of each droplet by using computational fluid dynamics. The Eulerian-Eulerian analysis method was used because the scrubber had a gas-liquid two-phase flow inside the scrubber. When the diameter of the droplet was $100{\mu}m$, $300{\mu}m$, $500{\mu}m$ and $700{\mu}m$. As a result, both of scrubbers showed high desulfurization efficiency and low evaporation amount at $500{\mu}m$ and $700{\mu}m$.