• Title/Summary/Keyword: Frost thickness

Search Result 76, Processing Time 0.026 seconds

An Experimental Study of Frost Formation on the Horizontal Cylinder (수평 실린더 표면의 착상에 대한 실험적 연구)

  • Paik, Sang-Jin;Lee, Yoon-Been;Ro, Sung-Tack
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.240-245
    • /
    • 2000
  • In this study, thickness, density and effective thermal conductivity of frost forming on the horizontal cylinder were measured with various air temperature and humidity. Reynolds number and temperature of cooling surface are controlled 17300 and $-l5^{\circ}C$ respectively. In each case of air temperature $5^{\circ}C,\;10^{\circ}C,\;15^{\circ}C,$ varying absolute humidity, experiments were executed. In measuring frost surface temperature and thickness of frost layer, infrared thermocouples and CCD camera were used. Frost was gathered from cylinder to measure mass of frost layer. Experimental data showed that the thickness and effective thermal conductivity of the frost layer increase with respect to time. Thickness of frost layer increase with humidity increasing, and density of frost layer increase with air temperature rising. Frost growth with air temperature and density of frost layer with humidity are affected by whether dew point is below or above freezing point.

  • PDF

A Study of Frost Formation on Different Hydrophilic Surfaces (다른 친수성능을 가진 두 표면에서의 착상에 관한 연구)

  • 김철환;신종민;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.519-524
    • /
    • 2002
  • An experimental study has been conducted to investigate the effects of surface energy on frost formation. Test samples with two different surfaces are installed in a wind tunnel and exposed to a humid airflow. Dynamic contact angles (DCA) for these surfaces are $23^{\circ}\;and\;88^{\circ}$, respectively. The thickness and the mass of frost layer are measured and used to calculate the frost density while frost formation is visualized simultaneously with their measurements. Results show that frost density increases as time increases at specific test conditions. The air Reynolds number, the airflow humidity and the cold plate temperature are maintained at 12,000, 0.0042 kg/kg and $-21^{\circ}C$, respectively. The surface with a lower DCA shows a higher frost density during two-hour test, but no differences in the frost density have been found after two hours of frost generation. Empirical correlations for thickness, mass and density are assumed to be the functions of the test time and DCA.

Experimental assessment of the effect of frozen fringe thickness on frost heave

  • Jin, Hyun Woo;Lee, Jangguen;Ryu, Byun Hyun;Shin, Yunsup;Jang, Young-Eun
    • Geomechanics and Engineering
    • /
    • v.19 no.2
    • /
    • pp.193-199
    • /
    • 2019
  • A frozen fringe plays a key role in frost heave development in soils. Previous studies have focused on the physical and mechanical properties of the frozen fringe, such as overall hydraulic conductivity, water content and pore pressure. It has been proposed that the thickness of the frozen fringe controls frost heave behavior, but this effect has not been thoroughly evaluated. This study used a temperature-controllable cell to investigate the impact of frozen fringe thickness on the characteristics of frost heave. A series of laboratory tests was performed with various temperature boundary conditions and specimen heights, revealing that: (1) the amount and rate of development of frost heave are dependent on the frozen fringe thickness; (2) the thicker the frozen fringe, the thinner the resulting ice lens; and (3) care must be taken when using the frost heave ratio to characterize frost heave and evaluate frost susceptibility because the frost heave ratio is not a normalized factor but a specimen height-dependent factor.

Development of Frost Thickness Measurement Method Using Optical Technique (광학적 기법에 의한 Frost 두께 측정방법의 개발)

  • Jeong, Jae-Hong;Yoon, Sang-Youl;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.654-659
    • /
    • 2001
  • A new non-contact method of the frost thickness measurement has been developed. The method is based on the digital image processing technique to identify the reflection edge of the image captured by a CCD camera under laser sheet light illumination. To insure the accuracy of frost layer thickness, an in-situ calibration procedure is carried out with a calibration target with 0.5mm holes. Using the mapping function obtained by the calibration procedure, the contour of frost surface can be estimated with sub-pixel resolutions. The developed method is applied to study the effect of cooling plate temperature on the frost thickness in a small low speed wind tunnel.

  • PDF

Empirical Correlations of Frost Properties on the Fin of a Heat Exchanger (열교환기 핀에서의 서리층 물성치에 대한 실험 상관식)

  • Kim, Kyoung-Min;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.11
    • /
    • pp.629-635
    • /
    • 2009
  • In this study, fin surface temperature and frost properties, i.e., frost thickness and frost surface temperature on a heat exchanger, were experimentally analyzed with different fin thicknesses, fin sizes and thermal conductivities of fin. As a result, it is found that fin thickness and thermal conductivity of fin should be considered in order to design an efficient heat exchanger fin. Correlations of dimensionless average frost properties were proposed as functions of dimensionless air temperature, dimensionless fin base temperature, dimensionless fin thickness, absolute air humidity, Reynolds number and Fourier number. The correlations predicted well the average frost thickness with a maximum error of 10.5% and frost surface temperature with a maximum difference of $0.89^{\circ}C$, respectively.

Estimation of Reinforced Railway Roadbed by Geosynthetics on Frost and Bearing Capacity (토목섬유로 보강된 철도노반의 동상 및 지지력 평가)

  • 심재범;채영수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.11c
    • /
    • pp.117-128
    • /
    • 1999
  • Geosynthetics have been studied especially Korean Railway earth works from the outset and have proved successful in both technical and economic terms. Hitherto Geosynthetics have been given consideration chiefly in dimensioning the requisite track subbase thickness, but have not been considered when calculating the thickness of the frost protection layer. this often made it impossible to reduce the thickness of the subbase. The article therefore puts forward a proposal for considering the German Geosynthetics in dimensioning the requisite thickness of the frost protection layer.

  • PDF

Theoretical Study on Heat Exchanger Performance of a Fin-tube Evaporator with Frost Growth in a $CO_2$ Refrigerator Truck (이산화탄소 냉매를 이용한 냉동탑차용 핀-관 증발기의 서리성장에 따른 열교환기 성능에 관한 해석적 연구)

  • Myung, Chi-Wook;Cho, Hong-Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.48-54
    • /
    • 2012
  • To analyze the cooling performance of fin-tube evaporator in the refrigerator truck using R744 according to frost growth, the analytical model of evaporator was developed under frost and non-frost conditions. The performance of fin-tube evaporator was investigated with frost thickness and indoor temperature. Besides, the performance of evaporator under frost condition was compared to that under non-frost condition. As a result, area of air passage and system performance were decreased as the frost thickness increased. The cooling capacity was reduced by 10%, 20%, 30% when the frost thickness was 0.7 mm, 1.1 mm, and 1.6 mm respectively. At these conditions, the block ratio was 31%, 48%, and 71%. In addition, the outlet quality of refrigerant was not over 1 when the frost thickness was 1.6 mm in spite of high indoor air temperature.

An Analysis on the Early Frost Damage According to the Component Thickness Changes of the Normal Strength Concrete Slab in Winter (겨울철 보통강도 콘크리트의 부재 두께 변화에 따른 초기동해 피해분석)

  • Kim, Tae-Woo;Lee, Yong-Jun;Kim, Dong-Gyu;Kim, Dae-Gun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.145-146
    • /
    • 2018
  • In this study, the purpose of the study is to determine the depth of damage caused by early frost damage in concrete slab structures under the conditions of external temperature during winter. In other words, we intend to analyze the depth variation of the early frost damage as the thickness of the normal strength concrete slab members changes. As a result, the thinner the component was, the deeper the early frost damage was found to be, and the resulting increase in brightness of the concrete was delayed. and It is analyzed that under this test condition, an early frost damage was created with a thickness of 50 mm for the member and a thickness of 39 mm for the member of 300 mm.

  • PDF

Analysis Study of Performance of CO2 Microchannel Evaporator According to Frost Growth (서리성장에 따른 이산화탄소용 마이크로채널 증발기의 성능에 관한 해석적 연구)

  • Shin, Eun-Sung;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.724-732
    • /
    • 2012
  • The microchannel evaporator with louver fin using carbon dioxide are analyzed according to the frost growth. To predict the performance of microchannel evaporator with the frost growth under low temperature, the simulation condition of previous studies was applied. As a result, the frost thickness increases and its increasing rate is reduced when the operating time increases. Frost thickness increases gradually below the quality of 0.74, and then it decreases rapidly. In addition, the frost growth of present model under same surface temperature is very similar trends with Moallem's test results. In case of low temperature application, the dimensionless frost thickness increases dramatically and it is about 0.86 after 10 minutes.

Frost Formation on a Cylinder under Heat Pump Condition (히트펌프 조건의 원형관에서의 착상에 관한 연구)

  • Yoon, Shin-Hyuk;Cho, Keum-Nam;Hayase, Gaku
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.804-809
    • /
    • 2009
  • The present study measured frost pattern on a cylinder to propose empirical correlation equations for the local and average frost thickness, frost density and frost mass. The key parameters were diameter of the cylinders (7mm, 20mm), cooling surface temperature of the circular tube, absolute humidity of air, air temperature and air velocity. A 50% ethylene glycol aqueous solution was applied as a coolant. The frost thicknesses at both front and rear were larger than those at the other parts, while they were increased as diameter of the cylinder was increased. The local frost thicknesses at high air velocity were more uniform than those at low air velocity. The values predicted by Kim et al. under the freezer condition showed larger by the maximum of $30{\sim}50%$ than the measured data under heat pump condition. The empirical correlations for the local and average frost thickness and frost mass were proposed. The correlation equations for the frost thickness and frost mass under the heat pump condition in the present study might predict more accurate than the other correlation equations. The proposed correlations might be applied for the freezer condition within the maximum 15% deviation from the previous correlations under freezer condition.

  • PDF