• Title/Summary/Keyword: Frost ratio

Search Result 87, Processing Time 0.026 seconds

Influencing Factors on Freezing Characteristics of Frost Susceptible Soil Based on Sensitivity Analysis (민감도 분석을 기반으로 한 시료의 동결 특성에 미치는 영향인자 분석)

  • Go, Gyu-Hyun;Lee, Jangguen;Kim, Minseop
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.8
    • /
    • pp.49-60
    • /
    • 2020
  • A fully coupled thermo-hydro-mechanical model is established to evaluate frost heave behaviour of saturated frost-susceptible soils. The method is based on mass conservation, energy conservation, and force equilibrium equations, which are fully coupled with each other. These equations consider various physical phenomena during one-dimensional soil freezing such as latent heat of phase change, thermal conductivity changes, pore water migration, and the accompanying mechanical deformation. Using the thermo-hydro-mechanical model, a sensitivity analysis study is conducted to examine the effects of the geotechnical parameters and external conditions on the amount of frost heave and frost heaving rate. According to the results of the sensitivity analysis, initial void ratio significantly affects each objective as an individual parameter, whereas soil particle thermal conductivity and temperature gradient affect frost heave behaviour to a greater degree when applied simultaneously. The factors considered in this study are the main factors affecting the frost heaving amount and rate, which may be used to determine the frostbite sensitivity of a new sample.

Experimental Study on the Evaluation of frost-Resistance of High-Strength Concrete Damaged by frost at Early Age in Cold Climates (동절기 초기재령에서 동해를 받은 고강도콘크리트의 내동해성 평가에 관한 실험적 연구)

  • 권영진
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.139-145
    • /
    • 2001
  • One of ways to make high-strength concrete is for the mix contain particles graded down to the finest size : this is achieved by the use of fly ash, silica fume which fills the spaces between the cement particle and between the aggregate and the cement particles. And, the mix needs a sufficient workability. This is achieved by the use of a superplasticizer. This study is to investigate frost resistance of high-strength concrete at early age, with ratio of tensile strength and recovery of compressive strength, when high-strength concrete is placed in cold climates. According to this study, it is necessary to ensure 4 % of air content, 5 kgf/$\textrm{cm}^2$ of tensile strength, at least, for frost resistance of high-strength concrete at early age.

Frost-Heaving Characteristics of Soil Mixed with Discarded Tire Powder (폐타이어 파우더 혼합토의 동상 특성)

  • Kim, Hak-Sam;Seo, Sang-Youl;Nakamura, Dai;Fukuda, Masami;Yamashita, Satoshi;Suzuki, Teruyuki
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.4
    • /
    • pp.15-26
    • /
    • 2010
  • To determine the frost heave suppressing mechanism of soil mixed with tire powder, we conducted three kinds of laboratory experiments: measurement of unfrozen water, evaluation of thermal conductivity, and a frost heave. In this research, we focused on changes in the coefficient of permeability of the mixed soil, and first found that of the unsaturated soil. Next, in the case of the presence of ice, we took the ice-impeding factor into consideration to derive the coefficient of permeability of the frozen fringe from the area ratio of the soil and tire powder in mixed soil. The results show a positive correlation between the water intake rate and the coefficient of permeability. Moreover, we found that the frost heave decreased thanks to a reduction in the permeability and a fall in the unfrozen water content of the soil mixed with tire powder. We also calculated the weight of the water content of the soil and tire powder void quantitatively using the result of the volumetric ratio of mixed soil.

Estimation of the Mean CBR for the Subgrade Layer Including the Anti-Frost Layer (동상방지층을 포함한 노상층의 평균 CBR 산정에 관한 연구)

  • Min, Gyeong-Ho;Lee, Cheo-Keun;Heo, Yol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 2002
  • Generally, the California Bearing Ratio(CBR) for the material of subgrade is estimated without considering the anti-frost layer into the subgrade layer when pavements are designed. A pavement structure is determined according to the CBR. However, recently the design method taking the anti-frost layer into the subgrade layer is getting prevail. It makes the top of the subgrade layer strengthen and the thickness of the road pavement structure decreased. By the way, some confusion may be caused because theoretically the general equation for the mean CBR to combine the material of the subgrade layer and anti-frost layer have not been developed well. In this paper, laboratory and field CBR tests were performed to estimate of the mean CBR for the subgrade layer including the anti-frost layer. From the basis of the test results, modified equation which is calculating the mean CBR of the subgrade layer has been proposed. Finally, economical efficiency was considered by comparing the pavement thickness with the road pavement design using CBR of the subgrade layer alone and the road pavement design using the mean CBR including the anti-frost layer.

  • PDF

ALC 의 내구성 및 물성개선에 관한 연구

  • 이범재;홍성수;황의환;조헌영;노재성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.65-70
    • /
    • 1993
  • The effect of particle size of Al powder, water repellent agent and finishing agent on frost resistance, absorption ratio and structure of micropore was examined to improve the physical properties and durability of ALC. According as the amount added of water repellent agent was increased, frost resistance was improved and absorption ratio was decreased. From one side freezing /thaw test, finishing agent which has a low vapor permeation located the crack at close indoor point of ALC specimen. ALC produced from fine Al powder has a low volume reduction by scalling and a sound appearance after freezing/thawing test and top surface freezing test, The crystal of tobermorite in ALC matrix was converted to calcium carbonate by carbonation which was accelerated with the decreasing of water content. Since the micropore of ALC was filled up by calcium carbonate, void ratio was reduced and crack was detected after complete carbonation.

  • PDF

Performance Comparison of Fin-Tube Type Evaporator using R134a and R1234yf under the Frost Condition (착상조건에서 R134a와 R1234yf를 적용한 핀-관 형태의 증발기 성능 비교)

  • Shin, Yunchan;Kim, Jinhyun;Cho, Honghuyn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.5795-5801
    • /
    • 2015
  • The low temperature distribution of the refrigerated and frozen food has been increased gradually. Refrigeration industry is using R134a refrigerant, which GWP is 1300. R1234yf is an alternative refrigerant of R134a because GWP of R1234yf refrigerant is just 4. Evaporator used in refrigeration truck refrigeration system is operated on low temperature condition. Accordingly, evaporator is formed frost and the formation of frost is rapidly decreased performance of evaporator. In this study, the performance of evaporator using R134a and R1234yf refrigerant was analyzed with operating conditions under frost condition. As a result, the performance of R134a evaporator according to air inlet temperature, relative humidity and evaporating temperature was more sensitive than R1234yf evaporator. Besides, the frost growth of R134a evaporator is steeper than that of R1234yf one.

The Property of Frozen Soil Mixed with Shredded Tire and Cement (폐타이어 분말 및 시멘트를 혼합한 동결토의 특성)

  • Kim, Young-Chin;Son, Seung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1487-1493
    • /
    • 2008
  • The frost heaving is related with thermal conduction rate and permeability. If the thermal conduction rate can be controlled, it is effective to prevent from frost heaving. If soil mixed with shredded tire which has relatively lower thermal conduction rate than soil, it helps preventing from frost heaving. However, in this case, the shear strength can get weak. In this study, we compared thermal conduction rate of soil and shredded tire, and test uniaxial compression strength of soil which is mixed with shredded tire and cement in different ratio.

  • PDF

A Study on the Engineering Characteristics of the plaster-soil uiiitures (석고플라스터 혼합토의 공학적 특성)

  • 도덕현;정성모
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.27 no.4
    • /
    • pp.53-60
    • /
    • 1985
  • The plaster mixed to loam and sandy soil from 4 to 12 percent by dry soil weight, and the compaction, permeability, CBR, unconfined compressive strength and freezingthawing test were performed The results obtained are summarized as follows; 1.The coefficient of permeability reduced sharply at the plaster content of 4 percent, and in the CBR test, the swelling ratio reduced by the increment of plaster content. 2.The addition of plaster increased the unconfined compressive strength by the cementing effect, and it was found that the optimum plaster content, existed with the soil type, which showed the maximum strength 3.It was possible to enhance the unconfined compressive strength of the gypsum-lime-soil mixtures when the optimum content of plaster was mixed to the hydrated lime. 4.In case of sandy soil, the relative frost heave decreased with the mixture of plaster, however in loam soil, the relative frost heave began to increase at the plaster content of 12 percent than non-treated soil. Therefore the optimum plaster content existed for protecting frost heave by the different soil type. 5.The above summarized results make it possible to expect the effects such as improvement of soil properties, decrement of permeability, increment of unconfined compressive strength, and protection of frost heave, etc, therefore, it is considered that it is possible to it is plaster as sub-base materials of road.

  • PDF

Freezing and Deflection Characteristics of Flexible Pavement Structure Using Frost Model Test (동상모형실험을 통한 아스팔트 포장체의 동결 및 처짐 특성)

  • Shin, Eun-Chul;Hwang, Soon-Gab;Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.3
    • /
    • pp.27-35
    • /
    • 2012
  • In this paper, the frost heaving and thawing characteristics of flexible pavement structure were evaluated in the large scale freezer which have a specification of temperature range $-20^{\circ}C{\sim}10^{\circ}C$ and $3.2m(L){\times}3.2m(B){\times}2.4m(H)$ in size. The insulated steel box with the size of $0.9m(L){\times}0.9m(B){\times}0.9m(H)$ was used to simulate actual pavement road structure. The variation of temperature, frost heave amount and frost heave pressure were measured through the instrument of TDS-602 data logger. LFWD (light falling weight deflectometer) was used to determine the change of deflection due to the frost heaving and thawing. Furthermore, the influence of aggregate layer to the freezing of the subgrade soil was studied to verify the function and effectiveness of the anti-freezing layer.

Effect of Air Void System of High Strength Concrete on Freezing and Thawing Resistance (고강도콘크리트의 동결융해저항에 미치는 기포조직의 영향)

  • 김생빈
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.1
    • /
    • pp.89-96
    • /
    • 1992
  • It is generally known that the frost-resistance of concrete is much affected by the air content in concrete and by the air void system or air distribution. And also the frost-resistance is believed to vary with the stre¬ngth of concrete. This article is prepared to describe, based on experiment, the effect of the air content and the air void system, particularly the effect of the spacing factor, on the freeze-thaw resistance of the high strength conc¬rete. For this purpose, I first worked on Non-AE concrete to make its compressive strength set about 400 to 500 kg/em'. However, the freeze-thaw test on the Non-AE concrete resulted in low durability factor, I.e., 10-2~0%. Thus to enhance the durability, another supplementary step was needed. I used AE admixture. which enhanced durability by changing the air content from 2% to 12%. The frost-thaw test was then performed 500 cycles on the 20 kind of concrete mixtures which differ in unit cement content and in water-cement ratio. Keywords : frost -resistance, air content, air void system, air distribution, spacing factor, freeze-thaw test, dur ability factor. capillary cavity, Linear Traverse Method.