• 제목/요약/키워드: Frost growth

검색결과 99건 처리시간 0.026초

플레이트 휜 코일형 증발기의 착상에 관한 기초 실험 (Basic Experiment on Frost of Plate Fin Coil Evaporator)

  • 백승문;김창영;한인근;김재돌;윤정인
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 추계 학술발표회 논문집
    • /
    • pp.211-216
    • /
    • 1999
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. In this report, a prediction taking into account the change of the fin efficiency due to the growth of the frost layer.

  • PDF

착상 거동예측을 위한 이론적 모델 (The theoretical Model for predicting the behaviors of the frost formation)

  • 이관수;이태희;허정회
    • 대한기계학회논문집B
    • /
    • 제20권3호
    • /
    • pp.1096-1105
    • /
    • 1996
  • A theoretical model of the frost formation has been presented to investigate the characteristics of the growth of frost layer by considering molecular diffusion of water vapor and heat generation caused by sublimation of water vapor in the frost layer. The present model was compared with existing experimental data as well as a previous model. The difference between the present model and existing experimental data was found to be about 6 percent. An analysis for the behavior of frost formation using present model shows a good agreement with the trend for a number of experimentally observed features. The present analysis can also provide the physical understanding on the phenomena of the frost formation.

열교환기 휜에서의 서리층 두께와 서리층 표면온도의 실험 상관식 (Empirical Correlations of Frost Thickness and Frost Surface Temperature on Heat Exchanger Fin)

  • 김경민;김정수;김장현;이관수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.798-803
    • /
    • 2009
  • In this study, dimensionless correlations of frost properties (i.e. the thickness and surface temperature of frost) on heat exchanger fin with nonuniform temperature distribution are proposed from frosting experiments. We analyzed the local fin temperature distribution, frost thickness and frost surface temperature on a 2D fin; in the airflow direction and the direction perpendicular to airflow. As a result, the frost growth on the fin had a close relation with fin heat conduction. The dimensionless correlations for the average frost properties were expressed as a function of dimensionless temperature, humidity ratio, Reynolds number, and Fourier number. These correlations agreed well with experimental data with the error less than 14%.

  • PDF

냉장고용 핀-튜브 증발기의 착상 성능해석에 관한 연구 (Numerical Analysis on the Frosting Performance of a Fin-tube Evaporator for a Refrigerator)

  • 이무연;이호성;장용희;김용찬
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.307-316
    • /
    • 2008
  • The objective of this study is to provide numerical and experimental data that can be used to investigate the performance characteristics of a flat plate fin-tube evaporator in household and commercial refrigerators under frosting conditions. Computer simulations with variations of operating conditions such as air inlet temperature, relative humidity, and geometries were performed to find out optimal design parameters of a fin-tube evaporator for household and commercial refrigerators. The tube-by-tube method was used in the simulation and the frost growth model was considered under frosting conditions. The developed analytical model predicted the decreasing rates of heat transfer capacity and air flow rate ratio within ${\pm}$10% compared to the experimental results for a refrigerator under real operating conditions. As a result, the frost thickness at $3^{\circ}C$ & 80% is increased 40% than that of $-3^{\circ}C$ & 80%, and the frost thickness at $3^{\circ}C$ & 90% is increased 30% than that of $3^{\circ}C$ & 60%. Accordingly, the operating time of the evaporator in the refrigerator was reduced with the increase of the decreasing rate of air flow rate ratio at each condition.

열교환기 휜에서의 착상 거동 (Behavior of frost formed on heat exchanger fins)

  • 김정수;이관수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2334-2339
    • /
    • 2008
  • This paper proposes an improved mathematical model for predicting the frosting behavior on a two-dimensional fin considering the heat conduction of heat exchanger fins under frosting conditions. The model consists of laminar flow equation in airflow, diffusion equation of water vapor for frost layer, and heat conduction equation in fin, and these are coupled together. In this model, the change in three-dimensional airside airflow caused by frost growth is accounted for. The fin surface temperature increased toward the fin tip due to the fin heat conduction. On the contrary, the temperature gradient in the airflow direction(x-dir.) is small throughout the entire fin. The frost thickness in the direction perpendicular to airflow, i.e. z-dir., decreases exponentially toward the fin tip due to non-uniform temperature distribution. The rate of decrease of heat transfer in the airflow direction is high compared to that in the z-direction due to more decrease in the sensible and latent heat rate in x-direction.

  • PDF

착상조건에서 R744 냉매 적용 탑차용 냉장시스템의 성능해석 (Performance Simulation of a R744 Refrigeration System in a Refrigerator Truck under a Frost Condition)

  • 김상훈;명치욱;조홍현
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.499-505
    • /
    • 2013
  • R744 has been appropriated for substitute refrigerant, because of its high stability, and environment-friendly nature as a natural refrigerant. To analyze the cooling performance of a refrigeration system in a refrigerator truck using R744 according to the blocking ratio, an analytical model of the refrigeration system was developed under frost conditions, using EES. The performance of the refrigeration system was predicted with the indoor and outdoor air temperature, outdoor air velocity, and compressor speed. As a result, the system performance decreased, with the increase of frost growth. When the blocking ratio was 40.4% in the basic condition, the refrigeration capacity was decreased by 27.1%, compared to the non-frost condition.

착상조건하에서 평행 평판 열교환기의 열 및 물질전달 (Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition)

  • 이관수;이태희;김우승
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF

루버형 휜을 가진 휜관형 열교환기의 착상현상 연구 (Study on the Frosting Phenomenon of the Fin and Tube Heat Exchanger with a Louvered Fin)

  • 김정국;코야마 시게루;쿠와하라 켄;박병덕
    • 한국산업융합학회 논문집
    • /
    • 제11권4호
    • /
    • pp.157-163
    • /
    • 2008
  • The present study investigated the pressure drop and the total frost mass of the louvered fin type heat exchanger, which is widely used at the air-conditioning system. The pressure drop due to the frosting phenomenon and the total frost mass were investigated by changing the wet bulb temperature condition of the inlet air. Hence the brain of 55wt% was used as a cooling solution instead of a common refrigerant. The temperature difference between the brine and the tube outside wall at the outlet of heat exchanger was $10^{\circ}C$, at maximum, higher than that at the inlet of heat exchanger. As the wet bulb temperatures were increased, the pressure drop was linearly increased due to the increment of frost mass. And the increment of heat exchange rate was smaller than that of inlet air enthalpy due to the increment of frost mass. The pressure drop of air side was rapidly increased due to the progress of frosting phenomena. The run time that the pressure drop occurred rapidly was decreased by the growth of frost.

  • PDF

Emerging Research Advancements to Overcome the Peach Spring Frost

  • Pandiyan Muthuramalingam;Rajendran Jeyasri;Yeonju Park;Seongho Lee;Jae Hoon Jeong;Yunji Shin;Jinwook Kim;Sangmin Jung;Hyunsuk Shin
    • 식물병연구
    • /
    • 제29권3호
    • /
    • pp.220-233
    • /
    • 2023
  • The phenomena of global warming has led to an increase in the average air temperature in temperate climates. Springtime frost damage is becoming more common, and after a period of dormancy, damage to buds, blooms, and developing fruits is greater significant than damage from low winter temperatures. Peaches are a crucial crop among moderate fruits. Spring frost damage in peaches can have a negative effect on crop growth, yield, and quality. It is noteworthy that these plants have evolved defenses against spring frost damage while being exposed to a variety of low temperatures in the early spring. In this current review, recent research advancements on spring frost damage avoidance in peaches were deliberated. Additionally, adaptive mechanisms of peach, such as deacclimation and reacclimation, were emphasized. Moreover, the emerging advancements using various omics approaches revealed the peach physiology and molecular mechanisms comprehensively. Furthermore, the use of chemical products and understanding the spring frost mechanisms through the use of environmental chamber temperature stimulation and infrared thermography studies were also discussed. This review is essential groundwork and paves the way to derive and design future research for agronomists and horticulturalists to overcome the challenges of spring frost damage avoidance and crop management in these circumstances.

착상조건하에서 핀-관 열교환기 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Fin-Tube Heat Exchanger under Frosting Condition)

  • 이관수;박희용;이태희;이남교;이수엽;이명렬
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.319-328
    • /
    • 1995
  • In this study, the experiment with 2rows-2columns fin-tube heat exchanger under forced convection and frosting condition is performed. The influence of each operating condition(the temperature of air, the humidity of air, the velocity of air, the temperature of coolant) on the growth of frost layer, air-side pressure drop, and characteristics of heat transfer is investigated. The experimental results show that the frost thickness increases rapidly in the early stage of frost formation and increases linearly after sometime. The frost thickness increases with the increase of the inlet air humidity and velocity and the decrease of inlet air temperature and coolant temperature. It is also found that the total energy transfer rate increases with the increase of inlet air temperature and velocity and with the decrease of inlet air humidity and coolant temperature.

  • PDF