• 제목/요약/키워드: Frost formation

검색결과 68건 처리시간 0.024초

충격공진시험을 이용한 노상토의 동결.융해시 강성도 변화 측정 (Stiffness change measurement for subgrade soils at freezing and thawing using impact resonance test)

  • 이재환;권기철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.686-691
    • /
    • 2009
  • Damage due to frost action in pavement structure system is creating either frost heave or stiffness-weakening of subgrade soil follow melting. The formation of ice lenses requires a frost-susceptible soil, freezing temperatures, and continuous water supply. Eliminating one of these conditions suffices to significantly reduce the intensity of frost action. It is important to know characteristics of subgrade soil in frost susceptibility or decide degree of freezing permission. Also, study on the stiffness variation of subgrade soil during freezing and thawing cycle is very important. In this study, Impact resonance test for subgrade soil at freezing and thawing confirms that is applied for.

  • PDF

Characteristic of Frost Formed on Thermally Conductive Plain Plastic Plate

  • Lee Jang-Seok;Lee Kwan-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권3호
    • /
    • pp.138-144
    • /
    • 2005
  • In order to select a new material for a heat exchanger, the frosting behavior of a thermally conductive plastic based on PBT was compared to the frosting behavior of aluminum and three types of plastics based on PTFE. The frosting behavior on the 1 mm thick PBT specimen was similar to that of the aluminum specimen but not that of the pure PTFE specimen. The properties of the frost formed on the specimens were affected by both the thermal conductivity and surface characteristics of the materials. The heat and mass transfer rates of the thermally conductive plastic were almost equivalent to those of the aluminum specimen.

공기분사식 제상장치 개발에 관한 실험적 연구 (Experimental Study for Development of Air Eject Defrost Equipment)

  • 한인근;김창영;김재돌;윤정인
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.277-284
    • /
    • 2001
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. Therefore, the proper defrosting operation period based on the new defrosting method is very important, and make a comparison between conventional method like electric defrost and new method in compression work, evaporation pressure, evaporation temperature.

동해방지를 위한 초기재령 콘크리트의 최소 양생 시간 예측 (Minimum Curing Time Prediction of Early Age Concrete to Prevent Frost Damage)

  • 배수원;이성태;김진근
    • 콘크리트학회논문집
    • /
    • 제19권1호
    • /
    • pp.27-37
    • /
    • 2007
  • 이 연구의 목적은 초기재령 콘크리트가 동해를 입을 경우가 예상될 때, 동해저항성을 확보하는데 필요한 최소 양생 시간의 예측법을 제안하는 것이다. 먼저, 실험을 통하여 동해시점이 지연될수록, w/c가 낮을수록, 그리고 1종 시멘트보다 3종 시멘트를 사용한 콘크리트가 동해에 의한 압축강도 감소율이 낮으며 동해는 얼음결정의 형성과 성장을 통해 발생됨을 확인하였다. 초기재령 콘크리트가 동해를 입었을 경우, 콘크리트 내에 존재하는 모세공극의 자유수가 얼음으로 상변화를 일으키면서 압축강도의 감소를 유발하므로 동해저항성은 모세공극의 포화도에 따라 결정된다. 따라서, 모세공극의 임계포화도 개념을 근거로 초기동해의 방지를 위한 최소양생시간의 예측법을 제안하였다.

착상시 설계인자에 따른 핀-관 열교환기의 성능변화에 관한 실험적 연구 (An Experimental Study on the Effects of Design Factors for the Performance of Fin-Tube Heat Exchanger Under Frosting Conditions)

  • 이관수
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2657-2666
    • /
    • 1995
  • In this study, the effects of design factors of finned-tube heat exchanger, such as fin spacing and fin array on the frost growth and heat exchanger performance are investigated under a frosting condition. The results show that the amount of frost, frost density and blockage ratio of air flow passage increase with decreasing fin spacing. Heat transfer rate increases momentarily at the initial stage of frosting and then decreases. After that heat transfer rate continues to increase again to reach a maximum value and then decreases dramatically. It is shown that the time required for heat transfer rate to reach a maximum value becomes shorter with decreasing fin spacing, and after a maximum value, heat transfer rate decreases very fast. The maximum allowable blockage ratio is introduced to determine the operation limit of a finned-tube heat exchanger operating under frosting condition and is obtained as a function of fin spacing. It is also shown that heat transfer rate of heat exchanger with staggered fin array increases about 17% and the amount of pressure drop of air increases about 1~2 mmH$_{2}$O, compared with those of in-line type heat exchanger under frosting condition.

다중센서 기반 서리관측 시스템의 개선: MFOS v2 (Improvement of Multiple-sensor based Frost Observation System (MFOS v2))

  • 김수현;이승재;김규랑
    • 한국농림기상학회지
    • /
    • 제25권3호
    • /
    • pp.226-235
    • /
    • 2023
  • 본 연구는 개선된 '다중센서 기반 무인 서리관측시스템(MFOS, Multiple-sensor based Frost Observation System)'을 소개하였다. 개선된 시스템인 MFOS v2는 엽면습윤센서를 기반으로 서리 감지는 물론, 서리 발생 주요 인자인 표면온도 예측을 위한 기능도 겸한다. 기존 관측 시스템은 1) 엽면습윤센서 표면이 대부분의 가시광선을 반사하기 때문에 RGB 카메라로 엽면습윤센서 촬영 시 표면에 발생한 얼음(서리) 관측이 어려움, 2) 일출 전과 후에 RGB 카메라 촬영 결과가 어두움, 3) 열적외선 카메라가 온도의 상대적인 고저만을 보여주는 단점들이 존재하였다. 엽면습윤센서 표면에 발생한 얼음(서리) 파악을 위해 검정색으로 표면 도색된 엽면습윤센서를 추가 설치하였고, 동일한 높이에 유리판들을 설치하여 얼음(서리) 발생 확인을 위한 보조 도구로 활용하였다. 일출 전과 후에 RGB 카메라 촬영을 위해 카메라 촬영 시간에 맞춰 전원이 On/Off 되도록 LED 조명을 연동시켜 설치하였다. 상대적인 온도의 높고 낮음 판단만 가능했던 기존의 열적외선 카메라도 픽셀당 온도 값 추출이 가능하도록 개선하였다. 이러한 개선 사항들을 반영한 MFOS v2는 실제 농경지에 설치하여 운영 중이며, 서리예측 모델에 들어갈 입력자료를 생산하는 진보된 서리 관측시스템으로서 중요한 역할을 할 것으로 기대된다.

냉각면 평판에서 착상 지연을 위한 임계공기온도 상관식 (Correlation of Critical Air Temperature for Frost Delay on a Cold Plate)

  • 김정수;김유일;김욱중;이관수
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1188-1195
    • /
    • 2006
  • This paper examines the critical air temperature at which frost formation does not occur on a cold plate in order to improve the efficiency of a heat pump. The critical air temperature on test points is obtained from numerical analysis and a correlation of the critical air temperature is derived as a function of frosting factors (air absolute humidity, air velocity, and cold plate temperature) by least square method. Experiments are carried out to verify the correlation proposed in this study, and the prediction obtained with the correlation agrees well with the experimental data. Based on the correlation, we propose the non-frosting regions according to frosting factors.

황화광의 침출반응 및 중간생성물의 안정도 (Leaching of Metal Sulfides and the Stability of Reaction Intermediates)

  • 이만승;최승훈
    • 자원리싸이클링
    • /
    • 제27권3호
    • /
    • pp.3-7
    • /
    • 2018
  • 고품위 산화광의 고갈로 인해 금속황화광의 제련공정의 개발이 중요해지고 있다. 금속황화광의 침출은 대부분 전기화학반응으로 크게 $H_2S$, S, ${SO_4}^{2-}$ 발생형으로 분류된다. 침출용액의 산도와 산화제의 종류 및 농도는 황의 중산생성물 형성에 큰 영향을 미친다. 산화성이 강한 침출용액에서 황 옥소음이온의 Frost도는 황의 산화수가 증가할수록 열역학적으로 안정함을 나타낸다.