• Title/Summary/Keyword: Front Panel

Search Result 218, Processing Time 0.027 seconds

Discharge Dynamics of AC Plasma Display Panel

  • Whang, Ki-Woong;Seo, Jeong-Hyun;Yoon, Cha-Keun;Chung, Woo-Joon;Kim, Joong-Kyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.53-57
    • /
    • 1999
  • To investigate the discharge dynamics of alternating current plasma display panel (ACPDP), we measured the spatio-temporally resolved VUV and IR emission by an intensified charge coupled device (CCD). The breakdown beings around the anode inner edge and moves towards the cathode surface. As the ionization intensifies in front of the cathode surface, another emission region appears on the anode surface. While the anode side emission does not move but grows, the cathode side emission moves out and spreads over the entire cathode surface. The discharge dynamics emission by a 2 dimensional numerical simulation suggests that a cathode-directed streamer formation play an important role.

  • PDF

A study of The Injection Mould of LCD Monitor (LCD Monitor 사출금형에 대한 연구)

  • Moon Y. D.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.48-53
    • /
    • 2004
  • Injection molded plastic parts have many surface defcts: Warpage, wedline, flowmark, zetting, scratching, shading and so on. In the desktop mnitor's case, Weld line have been one of the main surface defects. Nowadays in the pursuit of light weight of parts, one of the big problems of LCD Monitor thinks Warpage and surface shrinkage. In this paper, we introduce some instances for prevevting these defestcs in the side of mould drawing, parts drawing and processing condition. Based on these, we tried to find out the optimum processing conditions through repeatedly tried injection moulding after reflecting these instances.

  • PDF

Discharge Characteristics of AC PDP Cell as a parameter of PDP Cell structure (표면방전형 PDP Cell의 상,하판 구조에 따른 방전특성)

  • Park, Young-Chan;Chi, Sung-Won;Kim, Gyu-Seup;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1749-1751
    • /
    • 1997
  • AC PDP with surface micro discharge has a structure that all discharge electrodes are arranged on the front glass panel, and the rear glass panel merely serves as a cover glass to form the micro discharge space. The relationships between the dischage voltage and the structure among such as electrode width, distance between electrodes, discharge space gap, and dielectric layer width are investigated.

  • PDF

Sound Absorbing Characteristics According to Interior Configuration of Noise Barrier (흡음형 방음벽의 내부 구성에 따른 흡음특성)

  • 박진규;김상헌;김관주;박희준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.387-392
    • /
    • 2003
  • This study is put a focus on the identification of sound characteristics according to the interior configuration of sound absorption material and air gap. Noise barrier is general consists of front perforated panel, air layer, sound absorption material, air gap and back plate. Noise barrier is required to the NRC value of 0.7. The absorbing performance of the noise barrier relies on the opening ratio of the perforated panel and the efficiency of the absorbing material. This study has observed the effect of opening ratio and hole size, the increase of sound absorbing performance by the configurations of sound absorption material and air gap. New designed noise barrier is achieved the acoustical performance of 0.87 the measurement in a reveration room.

  • PDF

Viewing angle switching of a liquid crystal panel by using 3-terminal electrode structure

  • Kwon, Yong-Hoan;Baek, Jong-In;Kim, Jae-Chang;Yoon, Tae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.399-402
    • /
    • 2007
  • We propose a method to achieve both wide viewing angle (WVA) and narrow viewing angle (NVA) characteristics with a single liquid crystal (LC) panel and a single backlight system by using 3-terminal electrode structure. We could control the viewing angle of a single LC cell by using the horizontal or vertical alignment of LC for the dark state at the front.

  • PDF

Analysis of Energy Flow and Barrier Rib Height Effect using Ray-Optics Incorporated Three-dimensional PDP Cell Simulation

  • Chung, Woo-Joon;Jeong, Dong-Cheol;Whang, Ki-Woon;Park, Jae-Hyeung;Lee, Byoung-Ho
    • Journal of Information Display
    • /
    • v.2 no.4
    • /
    • pp.46-51
    • /
    • 2001
  • Using ray-optics code incorporated with three-dimensional PDP cell simulation, we have analysed the energy flow in the PDP cell from the electric power input to the visible light output. Also, the visible light output profile and viewing angle distribution were obtained. We applied our code to the analysis of the barrier rib height effect on the visible light luminance and efficiency of the sustaining discharge. Although cells with higher barrier rib generate more VUV photons, less ratio of visible photons are emitted toward front panel due to the shadow effect. Thus, there exists optimal barrier rib height giving the highest visible luminance and efficiency. This kind of code can be a powerful tool in designing cell geometry.

  • PDF

Flow Analysis and Evaluation of Injection-Molded Front Panel (백라이트 패널(back light panel)의 유동해석 및 평가)

  • 강성남;허용정
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.11a
    • /
    • pp.144-146
    • /
    • 2001
  • The synthesis of injection-molded parts has been done empirically, since it requires profound knowledge about injection molding which is not available to designers through current CAD systems. Appropriate U3 programs for mold design analysis to an existing geometric modeler is used to provide designers, at the initial stage, with comprehensive process knowledge for synthesis, performance analysis and feature-based geometric modeling.

2-Dimensional Numerical Analysis of Crossing Tunnel under Railroad using Roof Panel Shield Method (RPS공법을 이용한 철도횡단터널의 2차원수치해석)

  • Shin, Eun-Chul;Roh, Jeong-Min;Lee, Eun-Soo;Kim, Kyeong-Mo;Kim, Jung-Hyi;Jung, Byung-Chul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.591-600
    • /
    • 2005
  • There are many cross tunnelling methods such as NTR, TRCM, Messer Shield, Front Jacking, and Pipe Roof Method. The advantages of adopting RPS(roof panel shield) method in crossing tunnel construction with comparing other existing cross tunnelling method are needed a little space and easy to change the direction of cutting shoe during the construction of pipe roof. The numerical analysis of RPS was performed for the application in the crossing tunnel under railroad. The earth pressure distribution and settlement were predicted when the RPS method was applied during the excavation for crossing railroad tunnel construction.

  • PDF

Numerical and Experimental Analyses of the Aerodynamic Characteristics of a Counter Rotating Axial Fan (엇회전식 축류홴의 공력 특성에 관한 전산 해석 및 실험)

  • Cho, Jin-Soo;Won, Yu-Phil;Lee, Moon-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.325-337
    • /
    • 2000
  • A study was done on the numerical and experimental analyses of the aerodynamic characteristics of a counter rotating axial fan. The numerical analysis uses the frequency domain panel method developed for the aerodynamic analysis of interacting rotating systems, which is based on the unsteady lifting surface panel method. Each stage of interaction involves the solution of an isolated rotor, the interaction being done through the Fourier transform of the induced velocity field. Numerical results showed good agreements with other experimental data for single and counter rotating propeller systems. And they were compared with the experimental results of the counter rotating axial fan studied in the present paper. The performance test was carried out based on the Korean Standard (KS B 6311). It was focused on the relative efficiency increase of a counter rotating system for a single rotating one, and effects of the axial distance between the front and rear rotors on overall fan performances were investigated. As a result, it was shown that the counter rotating axial fan has the efficiency 14% higher than the single rotating one at peak efficiency points.

A new method for monitoring an OLED panel for lighting by sensing the wave-guided light

  • Han, Jun-Han;Moon, Jaehyun;Shin, Jin-Wook;Joo, Chul Woong;Cho, Doo-Hee;Hwang, Joohyun;Huh, Jin Woo;Chu, Hye Yong;Lee, Jeong-Ik
    • Journal of Information Display
    • /
    • v.13 no.3
    • /
    • pp.119-123
    • /
    • 2012
  • In this work, we report on a new monitoring method for an organic light-emitting diode (OLED) panel for lighting by optical sensing of the wave-guided light in the substrate. Using microlens array films, the wave-guided light was extracted into the edge or back side of the panel to be monitored by a photodiode. The luminance of the extracted light was measured as linearly proportional to the front light. Thus, by converting the extracted light into photo voltage, monitoring the luminance change occurring in the OLED is possible. Based on the results and concepts, we have proposed a photodiode-equipped driving circuit which can generate compensated driving current for uniform luminance of OLED panels.