• Title/Summary/Keyword: Frequency tracking control

Search Result 288, Processing Time 0.028 seconds

새로운 방식의 단상 인버터를 이용한 태양광 시스템 구현 (A New Solar Energy Conversion System Implemented using Single Phase Inverter)

  • 홍정표;김태화;원태현;권순재;홍순일;김종달
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.488-491
    • /
    • 2006
  • In this paper proposed method of maximum power point tracking using boost converter for a connected single phase inverter with photovoltaic system. The maximum power point tracking control is based on generated circuit control MOSFET switch of boost converter and single phase inverter uses predicted current control to control four IGBT's switch in full bridge. The predicted current control provide current with sinusoidal wave shape and inphase with voltage. The generation control circuit allows each photovoltaic module to operate independently at peak capacity, simply by detecting of the output power of the system. Furthermore, the generation control circuit attenuates low-frequency ripple voltage, which is caused by the full-bridge inverter, across the photovoltaic modules. Consequently, the output power of system is increased due to the increase in average power generated by the photovoltaic modules. The effectiveness of the proposed inverter system is confirmed experimentally and by means of simulation.

  • PDF

적응 Feedforward를 이용한 자기베어링 고속 주축계의 전기적 런아웃 제어 (Runout Control of a Magnetically Suspended High Speed Spindle Using Adaptive Feedforward Method)

  • 노승국;경진호;박종권
    • 한국정밀공학회지
    • /
    • 제19권12호
    • /
    • pp.57-63
    • /
    • 2002
  • In this paper, the feedforward control with least mean square (LMS) adaptive algorithm is proposed and examined to reduce rotating error by runout of an active magnetic bearing system. Using eddy-current type gap sensor fur control, the electrical runout caused by non-uniform material properties of sensor target produces rotational error amplified in feedback control loop, so this runout should be eliminated to increase rotating accuracy. The adaptive feedforward controller is designed and examined its tracking and stability performances numerically with established frequency response function. The tested grinding spindle system is manufactured with a 5.5 ㎾ internal motor and 5-axis active magnetic bearing system including 5 eddy current gap sensors which have approximately 15 ~ 30 ${\mu}{\textrm}{m}$ of electrical runout. According to the experimental analysis, the error signal in radial bearings is reduced to less than 5 ${\mu}{\textrm}{m}$ when it is rotating up to 50,000 rpm due to applying the feedforward control for first order harmonic frequency, and vibration of the spindle base is also reduced about same frequency.

Smoothing Output Power Variations of Isolated Utility Connected Multiple PV Systems by Coordinated Control

  • Datta, Manoj;Senjyu, Tomonobu;Yona, Atsushi;Sekine, Hideomi;Funabashi, Toshihisa
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.320-333
    • /
    • 2009
  • A Photovoltaic (PV) system's power output varies with the change of climate. Frequency deviations, tie line voltage swings are caused by the varying PV power when large PV power from several PV systems is fed in the utility. In this paper, to overcome these problems, a simple coordinated control method for smoothing the variations of combined PV power from multiple PV systems is proposed. Here, output power command is formed in two steps: central and local. Fuzzy control is used to produce the central smoothing output power command considering insolation, variance of insolation and absolute average of frequency deviation. In local step, a simple coordination is kept between the central power command and the local power commands by producing a common tuning factor. Power converters are used to achieve the same output power as local command power employing PI control law for each of the PV generation systems. The proposed method is compared with the method where conventional Maximum Power Point Tracking (MPPT) control is used for each of the PV systems. Simulation results show that the proposed method is effective for smoothing the output power variations and feasible to reduce the frequency deviations of the power utility.

밀리미터파 추적레이더 송·수신 구성품의 적용성 검증을 위한 신호획득장치 개발 (Development of a Signal Acquisition Device to Verify the Applicability of Millimeter Wave Tracking Radar Transmission and Receiving Components)

  • 최진규;신영철;홍순일;류한춘;김홍락;주지한
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.185-190
    • /
    • 2023
  • 최근 추적레이더는 다양한 환경에서 높은 해상도로 표적의 정보를 획득하기 위한 밀리미터파 추적레이더의 개발을 요구한다. 밀리미터파 추적레이더의 개발은 밀리미터파 추적레이더에 적용할 수 있는 송·수신 구성품의 개발과 동시에 추적레이더의 적용성을 필요로 한다. 개발된 송·수신 구성품의 적용성을 검증하기 위해서는 추적레이더의 운용개념을 적용한 송·수신 구성품을 제어하고, 상태를 확인할 수 있는 신호획득장치의 개발을 요구한다. 본 논문에서는 밀리미터파 추적레이더를 위해 개발된 구성품의 적용성을 확인할 수 있는 신호획득장치를 설계하였다. 구현한 신호획득장치는 수신신호를 검증하기 위해 4채널에서 입력되는 OOOMHz의 중심주파수와 OOOMHz 대역폭의 신호를 실시간으로 처리하기를 요구한다. 또한 추적레이더의 운용개념을 적용한 구성품 제어는 RS422, RS232, SPI 통신과 송수신구간 제어신호 생성으로 제어를 할 수 있도록 설계하였다. 마지막으로 신호획득장치 성능시험으로 구현한 신호획득장치를 검증하였다.

Mitigation of Low Frequency AC Ripple in Single-Phase Photovoltaic Power Conditioning Systems

  • Lee, Sang-Hoey;An, Tae-Pung;Cha, Han-Ju
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.328-333
    • /
    • 2010
  • A photovoltaic power conditioning system (PV PCS) that contains single-phase dc/ac inverters tends to draw an ac ripple current at twice the output frequency. Such a ripple current perturbs the operating points of solar cells continuously and it may reduce the efficiency of the current based maximum power point tracking technique (CMPPT). In this paper, the ripple current generation in a dc link and boost inductor is analyzed using the ac equivalent circuit of a dc/dc boost converter. A new feed-forward ripple current compensation method to incorporate a current control loop into a dc/dc converter for ripple reduction is proposed. The proposed feed-forward compensation method is verified by simulation and experimental results. These results show a 41.8 % reduction in the peak-to peak ac ripple. In addition, the dc/ac inverter control system uses an automatic voltage regulation (AVR) function to mitigate the ac ripple voltage effect in the dc link. A 3kW PV PCS prototype has been built and its experimental results are given to verify the effectiveness of the proposed method.

공진형 인버터를 위한 범용 퍼지 논리 제어기 설계 (General Digital Fuzzy Logic Controller Design For Resonant Inverter)

  • 김태언;김남수;임영도
    • 융합신호처리학회논문지
    • /
    • 제5권1호
    • /
    • pp.60-65
    • /
    • 2004
  • 고주파 유도 가열 시스템에서 철과 같은 물체를 가열하게 되면, 가열된 금속이 큐리점 부근에서 전기적인 임피던스가 급격하게 변화하는 특징을 가지는 시변 시스템이 된다. 또한 부하 임피던스가 변화함에 따라 시스템의 부하 공진 주파수가 달라지므로 해서 시스템의 효율이 감소하는 문제점이 있었다. 그리고, 피가열 물체의 용융이나 삽입 상태에 따른 시스템의 단락 현상으로 인해 시스템이 파괴되는 문제점이 있었다. 본 논문에서는 이런 문제점을 해결하기 위한 방법으로 PLL에 의한 부하 공진 주파수를 추종하면서 스위칭 손실을 줄이고, 시변 부하에 대한 유도 가열시 큐리점 부근의 급격한 부하 임피던스 변화에도 안정된 정전력 제어가 가능할 뿐 아니라 대전력용에 적합하고, 단락현상으로부터 시스템을 보호하는 병렬 공진형 인버터 시스템에 적용되는 퍼지논리 제어기를 설계하였다.

  • PDF

국내 MCS 시스템 현황 및 발전 방향 (Survey on the Korean MCS Systems and Development Issues)

  • 김건웅;박계각;최조천
    • 한국정보통신학회논문지
    • /
    • 제13권10호
    • /
    • pp.2019-2029
    • /
    • 2009
  • 해양안전 제고를 위해서 국내에서 운영 중인 MCS(Monitoring, Control and Surveillance) 시스템으로는 AIS(Automatic Identification System)와 LRIT(Long-Range Identification and Tracking) 기술에 기반을 둔 VMS(Vessel Monitoring System)와 RFID(Radio Frequency IDentification) 기술을 활용하고 있는 선박프리패스 시스템, 수협중앙회의 어업정보통신이 있다. 본 논문에서는 각 시스템의 기반 기술 현황을 정리하고, 각 시스템들의 역할과 기능을 비교하며, 각 시스템의 진화 방향과 이들을 유기적으로 연동하기 위해 수행되어야 하는 과제들을 정리하였다.

Current Status of KASI Solar Radio Observing System

  • 봉수찬;황보정은;박성홍;박종엽;박영득;이대영
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.64.2-64.2
    • /
    • 2013
  • Korea Astnonomy and Space Science Institute (KASI) operates two solar radio observing facilities, the Korean station of the e-CALLISTO and the Korean Solar Radio Burst Locator (KSRBL). The e-CALLISTO station had suffered from tracking problem for past several years. Since 2011, KASI has developed a new tracking system, and recently the antenna has regained the its sun-tracking capability and full day-time coverage. The KSRBL also suffered from the control computer breakdown last year. After one year of operational gap, the KSRBL restored its normal daily observation. We also expanded the data server storage capacity, to store the full original data of 25 ms integration time and 0.25 MHz frequency resolution, amounting to about 80 GB per day.

  • PDF

외란보상기를 이용한 영구자석 동기전동기에 대한 참조모델 견실적응제어기의 성능개선 (Performance Enhancement of RMRAC Controller for Permanent Magnent Synchronous Motor using Disturbance compensator)

  • 김홍철;임훈;이장명
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.845-851
    • /
    • 2008
  • A simple RMRAC (Robust Model Reference Adaptive Control) scheme for the PMSM (Permanent Magnent Synchronous Motor) is proposed in the synchronous frame. A current control of PMSM is the most inner loop of electro-mechanical driving systems and it requires a fast and simple control law to play a foundation role in the control hierarchy. In the proposed synchronous current model, the input signal is composed of a calculated voltage by proposed adaptive laws and real system disturbance. The gains of feed-forward and feedback controllers are estimated by the proposed modified Gradient method respectively, where the system disturbances are assumed as filtered current tracking errors. After the estimation of the system disturbances from the tracking errors, the corresponding voltage is fed forward to control input voltage to compensate for the disturbances. The proposed method is robust against high frequency disturbance and has a fast dynamic response. It also shows a good real-time performance due to it's simplicity of control structure. Through the simulations and real experiments, efficiency of the proposed method is verified.

압전 작동기를 이용한 방향 제어 밸브의 동적 모델링 및 제어 (Dynamic Modeling and Control of Directional Control Valve Using Piezostack Actuator)

  • 전준철;한영민;구오흥;한승훈;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.331-336
    • /
    • 2012
  • This paper proposes a new type of high-frequency directional valve controlled by the piezostack actuator associated with displacement amplifier. As a first step, a dynamic model of directional valve which can operate at 200 Hz with a flow rate of 12 l/min is derived by considering pressure drop and flow force. As a second step, an appropriate piezostack is selected by considering actuation force as well as field-dependent displacement. Subsequently, in order to control spool displacement and flow rate a proportional-derivative (PD) controller is designed based on the $3^{rd}$-order valve system. Control performances such as sinusoidal trajectory tracking of the spool displacement in time domain are evaluated. In addition, the field-dependent flow rate is also presented to verify the required performance of the valve system.

  • PDF