• Title/Summary/Keyword: Frequency shift

Search Result 1,219, Processing Time 0.032 seconds

A Study On The High Frequency Switching Of Zero Voltage Switching Converter (영전압 스위칭 컨버터의 고속 스위칭에 관한 연구)

  • Kim, In-Soo;Kim, Eui-Chan;Lee, Byung-Ha;Sung, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.537-539
    • /
    • 1996
  • In this paper, a design method of the phase shift ZVS-PWM converter is proposed to minimize the volume and increase the efficiency. The trade-offs of switching frequency, efficiency vs volume and ZVS range vs efficiency is also presented. The simulation of the designed converter is performed using the P-SPICE in which a phase-shift controller is proposed. For minimization of the converter volume, switching frequency is selected 100kHz, a simple drive circuit and single auxiliary supply are applied. In consideration of efficiency and load condition, ZVS range is decided from 50% to full load. A 28V, 1Kwatt prototype converter, of which the switch is MOSFET is made, verified the performance.

  • PDF

Synchronization Design of Satellite TDMA Network

  • Ko, Kyung-Su;Oh, Il-Hyuk;Yoo, Youn-Sang;Oh, Sang-Kyun;Lee, Hui-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.7A
    • /
    • pp.552-559
    • /
    • 2012
  • In this paper, we introduce a frame structure of the satellite TDMA network and the synchronization method thereof. The primary station transmits a special burst called reference burst which provides reference time to network. By using this reference burst all nodes achieve initial acquisition and synchronization. We consider time drift due to the node and satellite mobility, time shift due to the node position, Doppler shift due to the node mobility and frequency offsets as important factors of the frame structure. Simulation results show that the proposed frame structure and synchronization method guarantee accurate synchronization performance when the node is even in low SNR as well as 25 kHz frequency offsets.

Development of a Fatigue Index Based on the Measurement of Localized Muscular Fatigue During the Cyclic Isometric Contraction (주기적 등척성 수축에서의 국소근육피로 측정을 통한 피로지수의 개발)

  • Jung, So-Ra;Chung, Min-Keun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.19 no.4
    • /
    • pp.87-96
    • /
    • 1993
  • Spectrum analysis of surface electromyogram (FMG) signals is an effective approach to the study of localized muscular fatigue during isometric contraction. Many investigators have con firmed the frequency of the EMG signals being lowered during sustained contaction. In this study, the cyclic loading tasks were performed, and a comparison was made for the median power frequency shift pattern of the EMG signals with the sustained contraction of the same load. The median power frequency shift of the EMG signals for the cyclic loading task was found to be a part of that for the sustained contraction. Based on this result, a new muscle fatigue index was computed by normalizing the duration of the sustained contraction. A fatigue index was obtained as a function of exertion level and the work/rest schedule. With the proposed fatigue index, it is possible to evaluate or predict the degree of muscular fatigue for a physically demanding task.

  • PDF

Collision-Induced Light Scattering. Relation Between Spectral Shape and Molecular Interaction (分子衝突에 依한 光散亂)

  • Hyung Kyu Shin
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.4
    • /
    • pp.240-246
    • /
    • 1973
  • An analytic expression for the intensity of collision-induced light scattering obstained by introducing both short-range and long-range effects on the induced anisotropy. By taking argon as a specific example, it is shown that a narrow band at small frequency shifts is caused by long-range effects, while a broad band in the far wing of the spectrum is due to short-range effects. The overall intensity is a synthesis of these two bands and does not follow a simple exponential form. As temperature increases, the intensity at large frequency shifts increases makedly, while at small frequency shifts it changes little.

  • PDF

A study on the computer diagnosis that apply Neural-Fuzzy algorithm accumulation detection of Partial Discharge signal (광섬유 내의 유도 브릴루앙 산란광을 이용한 초고압전력케이블 열화진단에 관한 연구)

  • Hwang, Kyoung-Jun;Yeoum, Keoung-Tae;Kim, Yong-Kab;Kim, Jin-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1558-1559
    • /
    • 2007
  • This study is an application field by using optical fiber. The system to measure sBs from optical fiber is designed, So it can be used as a temperature sensor. by using frequency shift, resulting from temperature changes. the frequency shift is checked by changing temperature from $25^{\circ}C$ to $69^{\circ}C$ with chamber in the laboratory and using 40Km optical fiber. It's also measured by varying the length of optical fiber The program to do the real-time monitoring and analyze the measured data is created to find accurate frequency. It can be used as an optical fiber sensor, which is capable of measuring temperature and distance by using sBs.

  • PDF

Surface elasticity-based modeling and simulation for dynamic and sensing performances of nanomechanical resonators

  • Kilho Eom
    • Advances in nano research
    • /
    • v.14 no.3
    • /
    • pp.285-294
    • /
    • 2023
  • The dynamic and sensing performances of nanomechanical resonators with their different boundary conditions are studied based on surface elasticity-based modeling and simulation. Specifically, the effect of surface stress is included in Euler-Bernoulli beam model for different boundary conditions. It is shown that the surface effect on the intrinsic elastic property of nanowire is independent of boundary conditions, while these boundary conditions affect the frequency behavior of nanowire resonator. The detection sensitivity of nanowire resonator is remarkably found to depend on the boundary conditions such that double-clamping boundary condition results in the higher mass sensitivity of the resonator in comparison with simple-support or cantilever boundary condition. Furthermore, we show that the frequency shift of nanowire resonator due to mass adsorption is determined by its length, whereas the frequency shift is almost independent of its thickness. This study enables a design principle providing an insight into how the dynamic and sensing performances of nanomechanical resonator is determined and tuned.

Electrostatic Coupling Intra-Body Communication Based on Frequency Shift Keying and Error Correction (FSK 통신 및 에러 정정을 통한 Intra-Body Communication)

  • Cho, Seongho;Park, Daejin
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.4
    • /
    • pp.159-166
    • /
    • 2020
  • The IBC (Intra-Body Communication) benefits from a wireless communication system for exchanging various kinds of digital information through wearable electronic devices and sensors. The IBC using the human body as the transmission channel allows wireless communication without the transmitting radio frequency waves to the air. This paper discusses the results of experiments on electrostatic coupling IBC based on FSK (Frequency Shift Keying) and 1 bit error correction. We implemented FSK communication and 1 bit error correction algorithm using the MCU boards and aluminum tape electrodes. The transmitter modulates digital data using 50% duty square wave as carrier signal and transmits data through human body. The receiver performs ADC (Analog to Digital Conversion) on carrier signal from human body. In order to figure out the frequency of carrier signal from ADC results, we applied zero-crossing algorithm which is used to detect the edge characteristic in computer vision. Experiment results shows that digital data modulated as square wave can be successfully transmitted through human body by applying the proposed architecture of a 1ch GPIO as a transmitter and 1ch ADC for as a receiver. Also, this paper proposes 1 bit error correction technique for reliable IBC. This technique performs error correction by utilizing the feature that carrier signal has 50% duty ratio. When 1 bit error correction technique is applied, the byte error rate at receiver side is improved around 3.5% compared to that not applied.

Novel Approach of a Phage-Based Magnetoelastic Biosensor for the Detection of Salmonella enterica serovar Typhimurium in Soil

  • Park, Mi-Kyung;Chin, Bryan A.
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.12
    • /
    • pp.2051-2059
    • /
    • 2016
  • To date, there has been no employment of a magnetoelastic (ME) biosensor method to detect Salmonella enterica serovar Typhimurium in soil. The ME biosensor method needs to be investigated and modified for its successful performance. The filtration method, cation-exchange resin method, and combinations of both methods were employed for the extraction of S. Typhimurium from soil. The number of S. Typhimurium and the resonant frequency shift of the ME sensor were then compared using a brilliant green sulfa agar plate and an HP 8751A network analyzer. A blocking study was performed using bovine serum albumin (BSA), polyethylene glycol (PEG), and casein powder suspension. Finally, the modified ME biosensor method was performed to detect S. Typhimurium in soil. The number of S. Typhimurium was significantly decreased from 7.10 log CFU/soil to 4.45-4.72 log CFU/soil after introduction of the cation-exchange resin method. The greatest resonant frequency shift of the measurement sensor was found when employing centrifugation and filtration procedures. The resonant frequency shift of the PEG-blocked measurement sensor was $3,219{\pm}755Hz$, which was significantly greater than those of the BSA- and casein-blocked ME sensor. The optimum concentration of PEG was determined to be 1.0 mg/ml after considering the resonant shift and economic issue. Finally, the modified ME biosensor method was able to detect S. Typhimurium in soil in a dose-response manner. Although these modifications of the ME biosensor method sacrificed some advantages, such as cost, time effectiveness, and operator friendliness, this study demonstrated a novel approach of the ME biosensor method to detect S. Typhimurium in soil.

Evaluation of High Attenuation Material Using Utrasonic Wave Analysis (초음파의 파형 해석에 의한 고감쇠 재료의 평가)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.364-370
    • /
    • 1995
  • The purpose of this paper was to develop a nondestructive evaluation method of sintered material by ultrasonic method. The density distribution of sintered material becomes inhomogeneous partially because of the friction between the powder and the die during compaction. The inhomogeneity was investigated by measurement of the energy attenuation coefficient and the shift of the center frequency in the frequency spectrum of the ultrasonic reflection echo. The experimental results showed that the center frequency of reflection wave depended linearly on the density of sintered materials. However, the attenuation coefficient decreased inversely as the density increased. This study shows that the shift of the center frequency in the frequency spectrum of reflection wave can be used to a nondestructive evaluation of sintered materials.

  • PDF

A Study on the Doppler Compensation Technique of 2-Step Kalman Filter in Mobile Satellite Communication System (이동위성 통신 시스템에서 2단 칼만필터에 의한 도풀러 보상기법에 관한 연구)

  • 강희조;고봉진;조성언
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.166-176
    • /
    • 2000
  • In this paper, the LEO system signal degradation is mainly due to fading and doppler shift, so that the analysis of the signal degradation and compensation techniques are very important. This paper propose a Kalman filter based two step Automatic Frequency Control(AFC) to combat large and time variant frequency offset in low earth orbit satellite communication systems. The proposed Kalman AFC method estimates a frequency offset in two steps, I. e., coarse and fine estimations, extending the frequency acquisition range to even for than the symbol rate. Furthermore, it can track well a time variation of frequency offset. It is shown that the proposed compensator is able to compensate for doppler shift more than several KHz.

  • PDF