• Title/Summary/Keyword: Frequency of resistance

Search Result 1,487, Processing Time 0.029 seconds

Investigation of wearing behaviors and consumer's needs for summer golf wear (하절용 골프웨어의 착용실태 및 소비자 요구도)

  • Kim, Jeong-Hwa;Lee, Sun-Young;Lee, Jung-Soon
    • Science of Emotion and Sensibility
    • /
    • v.10 no.2
    • /
    • pp.177-186
    • /
    • 2007
  • The purposes of this study were to investigate consumer's needs for golf wear and to suggest a direction of product development and planning, based on the analysis of golfer's needs. The subjects used for the research were 150 male and female golfers who were in golf practice fields. The data were analyzed by frequency analysis, factor analysis, ANOVA, t-test and Duncan test. In summary, the results of this study were as followers; Dimensions of consumer's needs for golf wear were extracted from factor analysis as following properties; fashion/design property, textile property, hygiene property, body-shaped property. The most important consumer's need for golf wear was "wearing comfort" and second one was "moisture absorbency" Respondents evaluated that wearing comfort, stretchability, tactile, size of golf wear were very important but price, pilling, shrinkage or color-fading after laundry of golf wear were relatively less important. The evaluation of consumer's needs for golf wear according to demographic information had significant difference. The female golfers were found to consider that fiber characteristics, easy-to-laundry, wrinkle resistance, stretchability, sewing quality were relatively more important, when compared with the male golfers. Also, There were significant differences on the evaluation of consumer's needs for golf wear on fiber characteristics, stretchability, brand name between age groups.

  • PDF

Development of an Automatic Comprehensive Condition Diagnosis System for Inductive Loop Detector Using Magnetic Field (자기장을 이용한 루프검지기 자동진단시스템 개발)

  • Kim, Nam-Sun;Lee, Seung-Hwan;Oh, Young-Tae;Lee, Choul-Ki;Kang, Jeung-Sik
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.5 s.83
    • /
    • pp.123-134
    • /
    • 2005
  • This research aims at developing a new method which can replace the existing method. known as the quality factor(Q factor) method by an L-R-C test for use in the performance test of inductive loop detectors(ILD) being installed and maintained. In this study, a sensor to detect a magnetic field in terms of frequency and intensity, a method to collect field data, the method of analysis, and the method of diagnosis were developed. An automatic diagnosis system which was developed to overcome those drawbacks has the following features : First, field data is collected automatically by a test vehicle equipped with magnetic field sensors that is running can be said to along the roadway and. thus, the new system completely overcome the roadway and, thus, the new system can be said to completely overcome the inefficiency of the existing method second, since the magnetic fold generated from the ILD is the final output of the whole system of ILD, the existing problem has been solved. third. since each of the detection area by height is collected by the magnetic sensors installed by height. a basic for the identification of the vehicle types to be detectable and the setting of adjustment factors has been made. For the automatic diagnosis system developed during in this study, a reliability test was carried out by comparing vehicle times of ILD installed ideally.

Development of Estimation Method for Velocity Pressure Exposure Coefficient of Buildings Based on Spatial Information (공간정보기반 건축물의 풍속고도분포계수 산정 방법 개발)

  • SEO, Eun-Su;CHOI, Se-Hyu
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.2
    • /
    • pp.32-46
    • /
    • 2017
  • Recent rapid urban expansion and crowding of various industrial facilities has affected the features of a significant part of downtown area, resulting in areas having buildings with a wide range of height and the foothills. To compute a velocity pressure exposure coefficient, namely the design wind speed factor, this study defines ground surface roughness by utilizing concentration analysis for the height of each building. After obtaining spatial data by extracting a building layer from digital maps, the study area was partitioned for the concentration analysis and to allow investigation of the frequency distribution of building heights. Concentration analysis by building height was determined with the Variation-to-Means Ratio (VMR) and Poisson distribution analysis using a buildings distribution chart, with statistical significance determined using Chi-square verification. Applying geographic information systems (GIS) with the architectural information made it possible to estimate a velocity pressure exposure coefficient factor more quantitatively and objectively, by including geographic features, as compared to current methods. Thus, this method is expected to eliminate inaccuracies that arise when building designers calculate the velocity pressure exposure coefficient in subjective way, and to help increase the wind resistance of buildings in a more logical and cost-effective way.

Studies on the Electrofusion Applied to the Yeast to Produce High Quantity of Organic Germanium (전기융합법을 이용한 게르마늄 강화 효모의 균주개발)

  • Oh, Sun-Woo;Lee, Sung-Hee;Lee, Hyun-Joo;Han, Eun-Sook
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.712-716
    • /
    • 2006
  • Saccharomyces cerevisiae and Zygosaccharomyces rouxii were electrofused and fermented in germaniumfortified nutrients to produce high-yield, organic germanium. The conditions for the preparation of protoplasts from both strains and for electrofusion were studied. The protoplasts of both cells formed long pearl chains and the cell membranes were lysed and fused through cellulase and high frequency voltage $(450{\sim}750V/128{\sim}512\;{\mu}sec)$. The fusants with the fastest growth were selected, and then characterized for their carbohydrate usage and tolerance to glucose and salts. The glucose tolerance of the fusants was better than that of S. cerevisiae and similar to that of Z. rouxii. The fusants appeared to have resistance to 12% NaCl. The cell size of the fusants was greater than that of the parental strains. The fusant cells contained more gemlanium than the parental cells did. The electrofusion of S. cerevisiae and Z. rouxii increased the cell capacity and accumulation of germanium in the yeasts. This method was proved to be effective to produce a high quantity of organic germanium.

Status of Infection Control in Jeju-area General Hospitals (제주특별자치도 종합병원의 감염관리 현황)

  • Chong, Moo Sang;Lee, Kyutaeg
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.130-136
    • /
    • 2016
  • The aim of this study was to examine and analyze the infection management status of Jeju-area general hospitals, and in order to convey the importance of infection management, and to determine role plans of medical technologists as infection management staff, the infection management status was examined through surveys targeting 7 general hospitals located in Jeju Special Self-Governing Province. The infection management of Jeju-area medical institutions showed excellence in that all institutions operated an infection management room, there was dedicated manpower, and hospital infection management guidelines were established and executed. However most institutions were operating their infection management room with only 1 nurse, reporting many difficulties in securing dedicated manpower, microbe-related culture deciphering, frequency of multiple-resistance bacteria, infection statistics, and details on microbe testing. Accordingly, it is believed that the medical technologist who can perform the practical tasks of infection management has sufficient qualification and experience in infection management as per the medical law enforcement regulations, and in operation of an infection management room. If medical technologists (infection control microbiological technologist) with expert knowledge on microbes and infection control nurses can execute the tasks as dedicated personnel, the operation of the infection management room will be more advanced. In addition, for proper infection management in the future, the introduction of a medical system specialized in infection management and full support for infection management of vulnerable small/medium hospitals in addition to general hospitals across the country is considered important.

Evaluating the Influence of Post-Earthquake Rainfall on Landslide Susceptibility through Soil Physical Properties Changes (지진이후 강우의 산사태 발생 영향성 평가를 위한 토양물성값 변화 분석)

  • Junpyo Seo;Song Eu;KiHwan Lee;Giha Lee;Sewook Oh
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.270-283
    • /
    • 2024
  • Purpose: Considering the rising frequency of earthquakes in Korea, it is crucial to revise the rainfall thresholds for landslide triggering following earthquake events. This study was conducted to provide scientific justification and preliminary data for adjusting rainfall thresholds for landslide early warnings after earthquakes through soil physical experiments. Method: The study analyzed the change in soil shear strength by direct shear tests on disturbed and undisturbed samples collected from cut slopes. Also, The study analyzed the soil strength parameters of remolded soil samples subjected to drying and wetting conditions, focusing on the relationship between the degree of saturation after submergence and the strength parameters. Result: Compaction water content variation in direct shear tests showed that higher water content and saturation in disturbed samples led to a significant decrease in cohesion (over 50%) and a reduction in shear resistance angle (1~2°). Additionally, during the ring shear tests, the shear strength was observed to gradually decrease once water was supplied to the shear plane. The maximum shear strength decreased by approximately 65-75%, while the residual shear strength decreased by approximately 53-60%. Conclusion: Seismic activity amplifies landslide risk during subsequent rainfall, necessitating proactive mitigation strategies in earthquake-prone areas. This research is anticipated to provide scientific justification and preliminary data for reducing the rainfall threshold for landslide initiation in earthquake-susceptible regions.

Effects of Alloying Elements and Heat-Treatments on Abrasion Wear Behavior of High Alloyed White Cast Iron

  • Yu, Sung-Kon
    • Journal of Korea Foundry Society
    • /
    • v.20 no.2
    • /
    • pp.104-109
    • /
    • 2000
  • Three different white cast irons alloyed with Cr, V, Mo and W were prepared in order to study their abrasion wear behavior in as-cast and heat-treated conditions. The specimens were produced using a 15㎏-capacity high frequency induction furnace. Melts were super-heated to $1600^{\circ}C$, and poured at $1550^{\circ}C$ into Y-block pepset molds. Three combinations of the alloying elements were selected so as to obtain the different types of carbides : 3%C-10%Cr-5%Mo-5%W(alloy No. 1: $M_7C_3$ and $M_6C$), 3%C -10%V-5%Mo-5%W(alloy No. 2: MC and $M_2C$) and 3%C-17%Cr-3%V(alloy No. 3: $M_7C_3$ only). A scratching type abrasion test was carried out in the states of as-cast(AS), homogenizing(AH), air-hardening(AHF) and tempering(AHFT). First of all, the as-cast specimens were homogenized at $950^{\circ}C$ for 5h under the vacuum atmosphere. Then, they were austenitized at $1050^{\circ}C$ for 2h and followed by air-hardening in air. The air-hardened specimens were tempered at $300^{\circ}C$ for 3h. 1 ㎏ load was applied in order to contact the specimen with abrading wheel which was wound by 120 mesh SiC paper. The wear loss of the test piece(dimension: $50{\times}50{\times}5$ mm) was measured after one cycle of wear test and this procedure was repeated up to 8 cycles. In all the specimens, the abrasion wear loss was found to decrease in the order of AH, AS, AHFT and AHF states. Abrasion wear loss was lowest in the alloy No.2 and highest in the alloy No.1 except for the as-cast and homogenized condition in which the alloy No.3 showed the highest abrasion wear loss. The lowest abrasion wear loss of the alloy No.2 could be attributed to the fact that it contained primary and eutectic MC carbides, and eutectic $M_2C$ carbide with extremely high hardness. The matrix of each specimen was fully pearlitic in the as-cast state but it was transformed to martensite, tempered martensite and austenite depending upon the type of heat-treatment. From these results, it becomes clear that MC carbide is a significant phase to improve the abrasion wear resistance.

  • PDF

Transformation Conditions and Ampicillin-resistant Expression of E. coli Ts-mutant (온도감수성 대장균의 형질전환조건 및 Ampicillin 내성의 표현)

  • JIN Deuk Hee;HONG Yong Ki
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.1
    • /
    • pp.57-62
    • /
    • 1987
  • The transformational conditions of plasmids $pPL-\lambda$ and pAS 1 are as follows in E. coli, Ts-mutant M 5248 strain at $30^{\circ}C$. When the culture time was 2.5 hours of mid logarithemic phase, the cell concentration was $4.5\times10^7\;cells/ml$, the optical density was equal to 0.45 at 590 nm wave length, the transformational frequencies of plasmid$pPL-\lambda$ and pAS 1 had the highest values as $2\times10^{-6}\;and\;1.5\times10^{-6}\;and\;1.5\times10^{-6}$ and respectively. For $9\times10^6$ competent cells in $200{\mu}l$, the transformational frequency was as high as $4.4\times10^{-6}$ at 510 ng plasmid concentration. The competent cells treated with the mixture of calcium chloride and thymidine twice rates of transformation than those treated with calcium chloride. The ampicillin resistance of transformants was expressed in LB broth after 2 hours at $30^{\circ}C$.

  • PDF

A Design of High Efficiency Distributed Amplifier Using Optimum Transmission Line (최적 전송 선로를 이용한 고효율 분산형 증폭기의 설계)

  • Choi, Heung-Jae;Ryu, Nam-Sik;Jeong, Young-Chae;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.1
    • /
    • pp.15-22
    • /
    • 2008
  • In this paper, we propose a numerical analysis on reversed current of distributed amplifier based on transmission line theory and proposed a theory to obtain optimum transmission line length to minimize the reversed currents by cancelling those components. The reversed current is analyzed as being simply absorbed into the terminal resistance in the conventional analysis. In the proposed analysis, however, they are designed to be cancelled by each other with opposite phase by the optimal length of the transmission lint Circuit simulation and implementation using pHEMT transistor were performed to validate the proposed theory with the cutoff frequency of 3.6 GHz. From the measurement, maximum gain of 14.5dB and minimum gain of 12.3dB were achieved In the operation band. Moreover, measured efficiency of the proposed distributed amplifier is 25.6% at 3 GHz, which is 7.6%, higher than the conventional distributed amplifier. Measured output power Is about 10.9dBm, achieving 1.7dB higher output power than the conventional one. Those improvement is thought to be based on the cancellation of refersed current.

Evaluation of Impedance on Biological Tissues Using Automatic Control Measurement System (자동제어 측정 시스템을 이용한 생체 조직의 임피던스 평가)

  • Kil, Sang-Hyeong;Lee, Moo-Seok;Kim, Sang-Sik;Shin, Dong-Hoon;Lee, Seong-Mo;Kim, Gun-do;Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.4
    • /
    • pp.239-244
    • /
    • 2015
  • Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection aganinst radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biblogical tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed. automatic control system.