• Title/Summary/Keyword: Frequency bias

Search Result 678, Processing Time 0.026 seconds

A Study on the Frequency Bias Setting of the AGC based on Frequency Response in Korea (전력계통 주파수응답 실적 기반의 국내 AGC 주파수 바이어스 설정치 산정에 관한 연구)

  • Kang, Bo-Ram;Kwon, Han-Na;Kook, Kyung-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.978-983
    • /
    • 2015
  • This paper presents Frequency Bias setting for the adequate AGC(Automatic Generator Control) operation based on the frequency response of power system in Korea. AGC frequency control recovers the frequency up to 60Hz following a primary control when the frequency suddenly drops due to a fault in power system. AGC can compensate an appropriate amount of generation by calculating ACE(Are Control Error) from the frequency deviation with the AGC frequency bias set from the actual frequency response in power systems. An appropriateness of the proposed AGC bias setting is verified through case studies employing the simulation model.

Correlates of Digit Bias in Self-reporting of Cigarette per Day (CPD) Frequency: Results from Global Adult Tobacco Survey (GATS), India and its Implications

  • Jena, Pratap Kumar;Kishore, Jugal;Jahnavi, G.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3865-3869
    • /
    • 2013
  • Background: Cigarette per day (CPD) use is a key smoking behaviour indicator. It reflects smoking intensity which is directly proportional to the occurrence of tobacco induced cancers. Self reported CPD assessment in surveys may suffer from digit bias and under reporting. Estimates from such surveys could influence the policy decision for tobacco control efforts. In this context, this study aimed at identifying underlying factors of digit bias and its implications for Global Adult Tobacco Surveillance. Materials or Methods: Daily manufactured cigarette users CPD frequencies from Global Adult Tobacco Survey (GATS) - India data were analyzed. Adapted Whipple Index was estimated to assess digit bias and data quality of reported CPD frequency. Digit bias was quantified by considering reporting of '0' or '5' as the terminal digits in the CPD frequency. The factors influencing it were identified by bivariate and logistic regression analysis. Results: The mean and mode of CPD frequency was 6.7 and 10 respectively. Around 14.5%, 15.1% and 15.2% of daily smokers had reported their CPD frequency as 2, 5 and 10 respectively. Modified Whipple index was estimated to be 226.3 indicating poor data quality. Digit bias was observed in 38% of the daily smokers. Heavy smoking, urban residence, North, South, North- East region of India, less than primary, secondary or higher educated and fourth asset index quintile group were significantly associated with digit bias. Discussion: The present study highlighted poor quality of CPD frequency data in the GATS-India survey and need for its improvement. Modeling of digit preference and smoothing of the CPD frequency data is required to improve quality of data. Marketing of 10 cigarette sticks per pack may influence CPD frequency reporting, but this needs further examination. Exploring alternative methods to reduce digit bias in cross sectional surveys should be given priority.

Dual Bias Frequency를 이용한 자화된 ICP에서 ACL 식각 특성 분석

  • Kim, Ji-Won;Kim, Wan-Su;Lee, U-Hyeon;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.376-377
    • /
    • 2013
  • 반도체산업이 발전함에 따라 패턴이 점점 더 복잡해 지고 있다. 이에 따라 웨이퍼 위에 올려지는 layer도 개수도 많아지고 점점 더 두꺼워진다. 예전에는 수백 nm였지만 최근에는 um단위까지 두꺼워지고 있다. 하지만 mask 역할을 하는 ACL과 substrate (SiO2)의 selectivity는 일정하기 때문에 mask 역할을 하는ACL layer 역시 두꺼워지는 것이 불가피하다. 이로인해 예전에는 없었던 문제들이 발생하기 시작한다. Mask 역할을 하는 ACL layer가 얇고 패턴 크기가 클 때에는 아무런 문제도 없었지만 ACL layer도 두꺼워 지고 패턴 크기도 수십 nm로 작아졌기 때문에 ACL 역시 식각 공정을 할 때 어려움이 생기기 시작한다. 이를 해결하기 위한 하나의 방법으로 자화된 ICP 챔버 substrate에 Dual bias frequency 인가하여 식각해 보고 이와같이 하였을 때 식각특성을 분석해 보았다. 자화된 ICP 챔버에서 substrate에 dual bias frequency를 인가함으로써 ion energy와 ion flux에 변화가 생기게 되고 이로 인해 다른 식각 특성이 나타나게 되었다. Dual bias frequency의 비율을 변화시켜 보고 변화에 따른 식각 특성을 분석해 보았다. 이와 같은 과정을 통하여 높은 주파수와 낮은 주파수의 각각의 변화에 따른 식각특성의 변화에 대한 이해를 할 수 있었다.

  • PDF

Effect of Bias Magnetic Field on Magnetoelectric Characteristics in Magnetostrictive/Piezoelectric Laminate Composites

  • Chen, Lei;Luo, Yulin
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.347-352
    • /
    • 2015
  • The magnetoelectric (ME) characteristics for Terfenol-D/PZT laminate composite dependence on bias magnetic field is investigated. At low frequency, ME response is determined by the piezomagnetic coefficient $d_{33,m}$ and the elastic compliance $s_{33}^H$ of magnetostrictive material, $d_{33,m}$ and $s_{33}^H$ for Terfenol-D are inherently nonlinear and dependent on $H_{dc}$, leading to the influence of $H_{dc}$ on low-frequency ME voltage coefficient. At resonance, the mechanical quality factor $Q_m$ dependences on $H_{dc}$ results in the differences between the low-frequency and resonant ME voltage coefficient with $H_{dc}$. In terms of ${\Delta}E$ effect, the resonant frequency shift is derived with respect to the bias magnetic field. Considering the nonlinear effect of magnetostrictive material and $Q_m$ dependence on $H_{dc}$c, it predicts the low-frequency and resonant ME voltage coefficients as a function of the dc bias magnetic field. A good agreement between the theoretical results and experimental data is obtained and it is found that ME characteristics dependence on $H_{dc}$ are mainly influenced by the nonlinear effect of magnetostrictive material.

Factors influencing arterial $CO_2$ tension in cats during high frequency oscillation ventilation (고빈도 진동 환기가 동맥혈의 호흡성 가스에 미치는 영향)

  • Do, Jun-Young;Lee, Jae-Yick;Lee, Kwan-Ho;Kim, Yeung-Jo;Chung, Jae-Chun;Lee, Hyun-Woo;Lee, Suck-Kang
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.47-55
    • /
    • 1989
  • High frequency ventilation (HFV) is a new ventilatory technique that uses very small tidal volume(less than the anatomic dead space) and high frequency, and classified 4 distinct types according to frequency and mode of gas delivery. The mechanism of gas transport of high frequency oscillation ventilation(HFOV) is somewhat different to other types of HFV. To evaluate the determinants of $PaCO_2$ in HFOV, a study was done with a HFOV on 9 cats, and the results are : 1) $PaCO_2$ was not correlated with frequency at the constant stroke volume(6 voltage) and bias flow (6L/minutes). 2) $PaCO_2$ was correlated with stroke volume but not with bias flow under the constant frequency(15Hz/min) and bias flow(3 to 6L/min). From above results, the main determinant of $PaCO_2$ on artificial ventilation with HFOV was stroke volume, but further study between flow, the site of delivery to the airway and humidification of bias flow and $CO_2$ elimination is required in future research.

  • PDF

Vibration Characteristics of Tires for Light-duty Truck under Free Suspension (자유상태에서 경상용차용 타이어의 진동특성)

  • 김용우;최동수
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.6
    • /
    • pp.49-56
    • /
    • 2000
  • Due to the rapid increase of long-distance transportation, particular attentions have been paid to truck tires, especially to their dynamic characteristics. In this research, experimental modal analysis on two kinds of light-duty truck tires, i.e., radial tire and bias tire, are performed by using GRFP(global rational fraction polynomial) method to investigate differences of the dynamic behavior of the two tires. The test results have shown that the modal frequencies of bias tire are much higher than the corresponding values of radial tire with a similar mode shape, which is in accordance with the fact that the radial rigidity of bias tire is higher than that of radial tire. And most of the modal decay rates of bias tire are larger than those of radial tire within the scope of this experiment. In the frequency domain range of test, the bias tire has extra modes, which do not occur in the radial tire. This difference is based on the fact that the circumferential rigidity of the bias tire is quire low whereas that of radial tire is so high that the frequencies of the corresponding modes are out of the frequency range of test.

  • PDF

Frequency modulation of a waveguide cavity cw IMPATT diode oscillator (도파관캐비티를 사용한 임팻다이오드 발진기의 주파수변조특성)

  • 윤현보
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.6
    • /
    • pp.1-4
    • /
    • 1975
  • This paper dells with the impedance variations of the IMPATT diode depending upon the small a.c. coomponent superimposed on the d.c. bias. The frequency deviation of the modulated wave is measured using a carrier null method on microwave spectrum analyser. Frequency modulation is achieved by the weack a.c. signal superimposed on the d.c. bias. The bandwidth rapidly increase with increasing modulation signal magnitude for constant modulation frquency and slightly decrease with decreasing modulation frequency for constant modulation signal magnitude.

  • PDF

Effects of Phase Difference between Voltage loaves Applied to Primary and Secondary Electrodes in Dual Radio Frequency Plasma Chamber

  • Kim, Heon-Chang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.2 s.11
    • /
    • pp.11-14
    • /
    • 2005
  • In plasma processing reactors, it is common practice to control plasma density and ion bombardment energy by manipulating excitation voltage and frequency. In this paper, a dually excited capacitively coupled rf plasma reactor is self-consistently simulated with a three moment model. Effects of phase differences between primary and secondary voltage waves, simultaneously modulated at various combinations of commensurate frequencies, on plasma properties are investigated. The simulation results show that plasma potential and density as well as primary self-dc bias are nearly unaffected by the phase lag between the primary and the secondary voltage waves. The results also show that, with the secondary frequency substantially lower than the primary frequency, secondary self·do bias remains constant regardless of the phase lag. As the secondary frequency approaches to the primary frequency, however, the secondary self-dc bias becomes greatly altered by the phase lag, and so does the ion bombardment energy at the secondary electrode. These results demonstrate that ion bombardment energy can be more carefully controlled through plasma simulation.

  • PDF

A Study on the Characteristic for EL Driving Resonant Inverter (EL 구동용 공진형 인버터 특성에 관한 연구)

  • 윤석암
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.380-383
    • /
    • 2000
  • This paper presents about EL(electro-luminescent) driver with inverter Inverter is constructed by using characteristic of FET and its output characteristics is analysed for the variation of gate bias frequency and load. The optimum operating condition of inverter is that the gate bias frequency of FET equal two resonant frequency of circuit.

  • PDF

Error Analysis of Inter-Frequency Bias Estimation in Global Navigation Satellite System Signals (위성항법 신호 이중주파수간 편이 추정오차 분석)

  • Kim, Jeongrae;Noh, Jeong Ho;Lee, Hyung Keun
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.20 no.3
    • /
    • pp.16-21
    • /
    • 2012
  • Global navigation satellite systems (GNSS) use dual frequency signals to remove ionosphere delay effect. GNSS receivers have their own biases, called inter-frequency bias (IFB) between dual frequencies due to differential signal delays in receiving each frequency codes. The IFB degrades pseudo-range and ionosphere delay accuracies, and they must be accurately estimated. Simultaneous estimation of ionosphere map and IFB is applied in order to analyze the IFB estimation accuracy and variability. GPS network data in Korea is used to compute each receiver's IFB. Accuracy changes due to ionosphere model changes is analyzed and the effect of external GNSS satellite IFB on the receiver IFB is analyzed.