• Title/Summary/Keyword: Frequency Response Method

Search Result 2,160, Processing Time 0.028 seconds

Application of Spectral Element Method for the Vibration Analysis of Passive Constrained Layer Damping Beams (수동감쇠 적층보의 진동해석을 위한 스펙트럴요소법의 적용)

  • Song, Jee-Hun;Hong, Suk-Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • This paper introduces a spectrally formulated element method (SEM) for the beams treated with passive constrained layer damping (PCLD). The viscoelastic core of the beams has a complex modulus that varies with frequency. The SEM is formulated in the frequency domain using dynamic shape functions based on the exact displacement solutions from progressive wave methods, which implicitly account for the frequency-dependent complex modulus of the viscoelastic core. The frequency response function and dynamic responses obtained by the SEM and the conventional finite element method (CFEM) are compared to evaluate the validity and accuracy of the present spectral PCLD beam element model. The spectral PCLD beam element model is found to provide very reliable results when compared with the conventional finite element model.

Frequency Response Function Based Substructural Analysis of Interior Noise (전달함수를 이용한 차실 소음의 부분구조 해석)

  • 황우석;이두호
    • Journal of KSNVE
    • /
    • v.10 no.3
    • /
    • pp.480-485
    • /
    • 2000
  • This paper presents the application of the substrctural analysis based on the frequency responses for the prediction of the interior noise in a car. The complex trimmed body with the high modal density is presented by the experimental data. Finite element model presents the powertrain and its subframes with the lower modal density. The substructural analysis based on the frequency responses combines the frequency response functions from the numerical analysis and the experiments. It describes the interior noise successwfully. Using this method we can pick up the most dominant paths for the booming noise and predict the effects of the design changes easily.

  • PDF

Non-contact type AFM using frequency separation scheme (주파수응답 분리방법을 이용한 비접촉식 AFM)

  • 이성규;염우섭;박기환;송기봉;김준호;김은경;박강호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.375-378
    • /
    • 2002
  • In this paper, the frequency response separation scheme is proposed for high scanning speed and simple structure of non-contact type of AFM. A self-sensing cantilever is attached on the actuator for detect the atomic force between tip and the media surface. VCM or PZT are used for actuator. This paper presents the method to simplify the actuator structure and the performance of each actuator for non-contact type AFM. Based on the frequency response separation scheme, the only one actuator plays roles 1311owing low frequency surface and modulating self-sensing cantilever tip in contrast with convention non-contact type AFM. 10 ${\mu}{\textrm}{m}$ standard grid sample imaged to verify proposed scheme. This result shows the possibility simplifying the actuator structure and reducing cost of non-contact type AFM.

  • PDF

Serviceability evaluation methods for high-rise structures considering wind direction

  • Ryu, Hye-Jin;Shin, Dong-Hyeon;Ha, Young-Cheol
    • Wind and Structures
    • /
    • v.30 no.3
    • /
    • pp.275-288
    • /
    • 2020
  • High-rise buildings are very slender and flexible. Their low stiffness values make them vulnerable to horizontal loads, such as those associated with wind or earthquakes. For high-rise buildings, the threat to serviceability caused by wind-induced vibration is an important problem. To estimate the serviceability under wind action, the response acceleration of a building at the roof height is used. The response acceleration is estimated by the same wind speed at all wind directions. In general, the effect of wind direction is not considered. Therefore, the response accelerations obtained are conservative. If buildings have typical plans and strong winds blow from relatively constant wind directions, it is necessary to account for the wind direction to estimate the response accelerations. This paper presents three methods of evaluating the response accelerations while considering the effects of wind direction. These three serviceability evaluation methods were estimated by combining the wind directional frequency data obtained from a weather station with the results of a response analysis using wind tunnel tests. Finally, the decrease in the efficiencies of the response acceleration for each serviceability evaluation method was investigated by comparing the response acceleration for the three methods accounting for wind direction with the response acceleration in which wind direction was not considered.

Effects of Carrier Wave on the Brain Stem Electric Response (BER) in Scala Tympanic Electrode Array

  • Duck-Hwann Lim;Byu
    • Journal of Biomedical Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.105-112
    • /
    • 1982
  • Using electronic cochlear implant system, we studied in cats the difference in the response of the brain stem evoked response (BER) during the stimulation with the acoustic signals and the electric signals. These brain stem electric responses were analyzed using the integral pulse frequency modulation method of the auditory nervous system. Animal experimental results and the analysis show that the carrier wave hasimprored the frequency specificity. of the electronic auditory prosthesis.

  • PDF

A Novel Frequency Tracker for Islanded-Mode Operation in Microgrid (마이크로그리드 독립운전모드를 위한 주파수 추종에 관한 연구)

  • Jeon, Jin-Hong;Kim, Kyoung-Hoon;Hwang, Chul-Sang;Kim, Jang-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1331-1338
    • /
    • 2011
  • This paper proposes a method for frequency control of islanded microgrid with battery energy storage system. For frequency control of islanded microgrid, battery energy storage system uses a phase locked loop algorithm with positive sequence components for a fast frequency estimation. Microgrid is a power system with small inertia because it has small capacity generators and inverter systems for renewable energy. So, Islanded microgrid's frequency varies fast and large as small generation and load changes. To reduce frequency variation of islanded microgrid, it needs a device with fast frequency response. For fast frequency response, a fast frequency tracking is important. To show the validation of proposed fast frequency tracking algorithm, battery energy storage system with proposed algorithm is tested in microgrid pilot plant.

A Study on Structural Dynamic Modification of Ship Structure by Using FRF Synthesis Method (전달함수 합성법을 이용한 선박구조변경)

  • Choi, Su-Hyun;Kim, Kuk-Su
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2006.09a
    • /
    • pp.53-58
    • /
    • 2006
  • When the vibration troubles occur on the ship structure during the sea trial, the rectification work is very restricted because of in-situ limitation. Usually the finite element method is used to improve vibration characteristics of the structure, but it takes lots of time and effort in modeling the structure and adjusting the finite element model in order to consider appropriate boundary conditions of a complex ship structure. Therefore, experimental methods have been in general suggested to obtain proper countermeasures without time-consuming in modeling. In this paper, FRF(frequency response function) synthesis method is applied to estimate natural frequency of the modified ship structure, which is obtained from experimental and numerical methods.

  • PDF

Experimental Study on Power Flow Analysis of Vibration of an Automobile Door (자동차 도어 진동의 파워흐름해석에 대한 실험적 연구)

  • Kil, H.G.;Lee, Y.H.;Lee, G.H.;Hwang, S.G.;Hong, S.Y.;Park, Y.H.;Seo, J.K.;Chae, G.S.;Seo, S.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.782-785
    • /
    • 2006
  • The Power Flow Analysis(PFA) can be effectively used to predict structural vibration in medium-to-high frequency range. In this paper, Power Flow Finite Element Method (PFFEM) based on PFA has been used to predict the vibration of an automobile door. The predicted results for the frequency response function of the door have been compared with corresponding experimental results. In the experiment, the automobile door has been divided into several subsystems and the loss factor of each subsystem has been measured. The input mobility at a source point has been also measured. The data for the loss factors and the input mobility have been used as the input data to predict the vibration of the automobile door with PFFEM. The frequency response functions have been measured over the surface of the door. The comparison between the experimental results and the predicted results for the frequency response functions showed that PFFEM could be an effective tool to predict the structural vibration.

  • PDF

Drain Current Response Delay High Frequency Model of SOI MOSFET with Inductive Parasitic Elements (유도성 기생성분에 의한 드레인전류 응답지연을 포함한 SOI MOSFET 고주파모델)

  • Kim, Gue-Chol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.959-964
    • /
    • 2018
  • In this paper, it was firstly confirmed that the drain current of the depleted SOI MOSFET operated in the high frequency response delay occurs by the inductive parasitic. Depleted SOI MOSFET cannot be applied as a conventional high-frequency MOSFET model because the response delay of the drain current is generated in accordance with the drain voltage fluctuation. This response delay may be described as a non-quasi-static effect, and the SOI MOSFET generated the response delay by the inductive parasitics compared to typical MOSFET. It is confirmed that depleted SOI MOSFET's RF characteristics can be well reproduced with the proposed method including the drain current response delay.

Analysis KTX wheel aged deterioration using Frequency Response Function (FRF를 이용한 KTX 차륜 경년변화 분석)

  • Yun, Cha-Jung;Lee, Sung-Uk;Jo, Kwang-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1453-1458
    • /
    • 2006
  • KTX Railway rolling stock wheel run its course to corrode, deteriorate and wear away through out the time. So it is natural that the performance and ability of wheel gets declined. The frequency characteristic analysis were accomplished to above trend and shock wave flow to wheels were examined. The result will be used to find Railway rolling stock wheel crack and maintenance method hereafter.

  • PDF