• Title/Summary/Keyword: Frequency Response

Search Result 5,517, Processing Time 0.036 seconds

Analysis of Noise Contribution using Frequency Response Function and Measurements of Noise Distribution for Railway Interior Noise (주파수 응답 함수를 이용한 철도차량 실내소음 기여도 분석 및 분포도 측정)

  • 김재철;유원희
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.949-954
    • /
    • 1999
  • Speed-up and mass reduction of railway vehicle usually causes increased of the interior noise. One of the best ways to control the interior noise is to identify the noise level radiated from each of parts in the cabin. In this paper, we describe the method to estimate the interior noise nad evaluate the noise contribution to each of parts. This method is based that the sound pressure can be calculated by using the frequency response function and acceleration. According to analysis of the noise contribution, we validated that the noise radiated from the floor is the higher in the cabin. We also measured the noise distribution for the side and floor by using the microphone array in order to analyze the effect of the noise flowing into the cabin from the outdoors. Finally, we presented the plan of the interior noise reduction based on the noise levels radiated from each of parts.

  • PDF

CORRECTION TECHNIQUES OF MASS-LOADING EFFECTS OF TRANSDUCERS IN MODAL TESTING

  • Guoyi Ji;Chung, Won-Jee;Lee, Choon-Man;Park, Dong-Keun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.188-188
    • /
    • 2004
  • Modal testing and analysis is a primary tool for obtaining reliable models to represent the dynamics of structures. When a structure is tested in order to collect measured data in modal testing, we usually use attached accelerometers to pick up the response data. Change in modal parameters due to the mass of transducers in modal testing is a well-known problem. The disadvantages are the shift of measured modal frequencies and the change of modal shapes, which can cause inaccurate results in further analysis. Modal analysis methods in frequency domain are based on a set of measured frequency response functions(FRF).(omitted)

  • PDF

Factors Affecting Acoustic Responses of Egg Shell (난각의 음향반응에 영향을 주는 인자)

  • 조한근;최완규
    • Journal of Biosystems Engineering
    • /
    • v.22 no.1
    • /
    • pp.41-48
    • /
    • 1997
  • A nondestructive quality inspection technique using acoustic impulse response method was studied to investigate the feasibility of egg shell inspection. An experimental system was built to generate impact force, to measure the response signal and to analyze the frequency spectrum. This system includes an impulse generating unit, an egg holding seat, a microphone with preamplifier, and a digital oscilloscope connected to Personal Computer by RS-232C interface. The factors such as impulse generating method, egg holding method, and sensor location were evaluated by analyzing the power spectrum density of the measured signal. The results obtained are summarized as follows : 1. From the sampled eggs, the proper conditions for detecting damaged eggs were found as followings; ceramic for the impact ball material, rubber for egg seat material, 20 degrees for an impact angle of pendulum, 10mm for the distance between egg and sensor, the sharp side for impacting part, and 180 degrees for the location of sensor. 2. Examination of the Fourier transformed analysis in beth normal and damaged eggs revealed that those factors such as the resonant frequency, a number of peak frequencies and the magnitude of power spectrum were important to detect damaged eggs.

  • PDF

System Identification of In-situ Vehicle Output Torque Measurement System (차량 출력 토크 측정 시스템의 시스템 식별)

  • Kim, Gi-Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.85-89
    • /
    • 2012
  • This paper presents a study on the system identification of the in-situ output shaft torque measurement system using a non-contacting magneto-elastic torque transducer installed in a vehicle drivline. The frequency response (transfer) function (FRF) analysis is conducted to interpret the dynamic interaction between the output shaft torque and road side excitation due to the road roughness. In order to identify the frequency response function of vehicle driveline system, two power spectral density (PSD) functions of two random signals: the road roughness profile synthesized from the road roughness index equation and the stationary noise torque extracted from the original torque signal, are first estimated. System identification results show that the output torque signal can be affected by the dynamic characteristics of vehicle driveline systems, as well as the road roughness.

Effects of a Degree of Discretization in the Direction of Longitudinal Dam Axis on the Results of 3-D Fill Dam Response Analysis (댐 축방향 분할도가 3차원 필댐 지진응답해석 결과에 미치는 영향)

  • Ha, Ik-Soo;Oh, Byung-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.72-83
    • /
    • 2009
  • The purpose of this study is to examine the effects of a degree of discretization in the direction of longitudinal dam axis on the results of three dimensional fill dam dynamic analysis. In this study, the three dimensional dynamic analyses of the existing 'H' dam which is modeled with a different degree of discretization were carried out. From these results, the fundamental frequency of the dam and the responses at the dam crest such as acceleration and settlement were compared and analyzed. It was concluded that the size of finite element discretized in the direction of the longitudinal axis mush be smaller than 1/8 of dam length in order to obtain the reasonable fundamental frequency and response of acceleration and mush be smaller than 1/10 in order to obtain the reasonable settlement behaviors from the three dimensional dynamic analysis of the fill dam.

  • PDF

Estimation of the Vibration Endurance Characteristics of Air Cleaner Insulators for Vehicles (차량용 에어클리너 인슐레이터의 진동 내구성 평가)

  • Kim Jung Heon;Kim Seockhyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.897-902
    • /
    • 2004
  • In this paper, a vibration endurance test is performed on rubber insulators used for vehicle air cleaners. Based on the test results, the endurance characteristics depending on the type and the material of the insulators are estimated. The frequency response characteristics of the air cleaner system including the insulator are investigated to identify the cause of wear and failure of the insulator. New insulator models with improved endurance characteristics are proposed and tested. Test results show that the vibration endurance property of the insulator is strongly dependent on the frequency response characteristics of the air cleaner system as well as the deformed shape of the insulator.

Dynamic Analysis of Mechanical Joint Parameters Using the Variation of Frequency Response Function (주파수응답함수의 변화를 이용한 기계적 결합부의 동특성 파라미터 해석)

  • 강성구;지태한;유원희;박영필
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.155-161
    • /
    • 1994
  • The dynamic behavior of a complex mechanical structure can be identified by dividing the structure into a series of smaller structure, called sub- structure and by studying the dynamic characteristics of these components. Generally, the dynamic characteristics of mechanical structure are strongly affected by the properties of joint parameters. In this paper, to identify the dynamic characteristics of mechanical structure, and experimental identification method in which directrly measured frequency response function(FRF) is used is considered. The method does not use the procedure of complex matrix calculation but use that of real matrix calculation. To confirm this method, computer simulation is performed by using frequency response function mixed with noise, and the experimental study is performed about the simple structure. The dynamic characteristics of joint parameters and identified more accurately than in using the prcedure of complex matrix calculation.

  • PDF

Study on Failure Diagnosis of Power Transformer Using FRA

  • Sano, Takahiro;Miyagi, Katsunori
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.324-329
    • /
    • 2006
  • As the average usage period of transformers increases, it is becoming increasingly necessary to know the internal condition of transformers. It is therefore critically important to establish monitoring and diagnostic techniques that can perform transformer condition assessment. Frequency response analysis, generally known as FRA, is one of the technologies to diagnose transformers. Using case studies, this paper presents the effectiveness of FRA as measurements for detecting transformer failures. This paper introduces the fact that FRA waveforms have useful information about diagnosis of failure on core earths and winding shield, and that the condition outside transformers can affect frequency response characteristics.

On the use of numerical models for validation of high frequency based damage detection methodologies

  • Aguirre, Diego A.;Montejo, Luis A.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.4
    • /
    • pp.383-397
    • /
    • 2015
  • This article identifies and addresses current limitations on the use of numerical models for validation and/or calibration of damage detection methodologies that are based on the analysis of the high frequency response of the structure to identify the occurrence of abrupt anomalies. Distributed-plasticity non-linear fiber-based models in combination with experimental data from a full-scale reinforced concrete column test are used to point out current modeling techniques limitations. It was found that the numerical model was capable of reproducing the global and local response of the structure at a wide range of inelastic demands, including the occurrences of rebar ruptures. However, when abrupt sudden damage occurs, like rebar fracture, a high frequency pulse is detected in the accelerations recorded in the structure that the numerical model is incapable of reproducing. Since the occurrence of such pulse is fundamental on the detection of damage, it is proposed to add this effect to the simulated response before it is used for validation purposes.

Feasibility study of bonding state detection of explosive composite structure based on nonlinear output frequency response functions

  • Si, Yue;Zhang, Zhou-Suo;Wang, Hong-fang;Yuan, Fei-Chen
    • Steel and Composite Structures
    • /
    • v.24 no.4
    • /
    • pp.391-397
    • /
    • 2017
  • With the increasing application of explosive composite structure in many engineering fields, its interface bonding state detection is more and more significant to avoid catastrophic accidents. However, this task still faces challenges due to the complexity of the bonding interface. In this paper, the concept of nonlinear output frequency response functions (NOFRFs) is introduced to detect the bonding state of explosive composite structure. The NOFRFs can describe the nonlinear characteristics of nonlinear vibrating system. Because of the presence of the bonding interface, explosive composite structure itself is a nonlinear system; when bonding interface of the structure is damaged, its dynamic characteristics show enhanced nonlinear characteristic. Therefore, the NOFRFs-based detection index is proposed as indicator to detect the bonding state of explosive composite pipes. The experimental results verify the effectiveness of the detection approach.