• 제목/요약/키워드: Frequency Auditory Feedback

검색결과 8건 처리시간 0.025초

문장읽기에서의 말더듬 감소율: 합독과 변조청각피드백 (Stuttering Reduction Rate during Sentence Reading: Choral Speech and Altered Auditory Feedback)

  • 박진;박희영
    • 말소리와 음성과학
    • /
    • 제4권4호
    • /
    • pp.109-115
    • /
    • 2012
  • This paper mainly aims to investigate how differently choral speech and altered auditory feedback (i.e., delayed auditory feedback, frequency-altered feedback) enhance speech fluency during sentence reading. To do this, a stuttering reduction rate was used and measured how much stuttering in frequency was reduced during each of the fluency enhancing conditions (i.e, typical choral reading, DAF, FAF) relative to typical solo reading. The results showed that stuttering frequency was reduced in the three fluency enhancing conditions and the highest mean value in stuttering reduction rate was observed during typical choral reading. Some discussion was provided in relation to the stuttering reduction rate observed during typical choral reading and its further speculation.

주파수 청각 피드백(FAF)에 따른 말더듬 특성 연구 (A Study on Characteristics of the Stuttering according to Auditory Feedback Types)

  • 장현진;신명선
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.940-947
    • /
    • 2009
  • 본 연구는 주파수 변조 피드백(FAF) 수준에 따라 말더듬인의 말더듬 빈도와 형태 변화를 밝히고자 하였다. 발달성 말더듬 성인 10명을 대상으로 NAF와 FAF 수준별(+2000, +1000, -1000, -2000) 상황에서 읽기 및 혼자말하기 과업을 통하여 수집한 구어 표본을 분석한 결과는 다음과 같다. 읽기 및 혼자말하기 과제 모두에서 NAF와 FAF 모든 수준 간에 말더듬 빈도의 유의한 차이가 있었으나, FAF 수준 간에는 차이가 없었다. 말더듬 형태는 두 과업 모두 NAF 수준 보다 FAF 수준에서 모든 핵심행동이 감소하였다. 특히 폐쇄가 많이 감소하였고 핵심행동이 주로 반복으로 변화하였다.

이중음성 판별에 있어 청지각적 평가의 임상적 유용성 (Clinical utility of auditory perceptual assessments in the discrimination of a diplophonic voice)

  • 배인호;권순복
    • 말소리와 음성과학
    • /
    • 제10권1호
    • /
    • pp.75-81
    • /
    • 2018
  • Diplophonia is generally defined as the perception of more than one fundamental frequency component in a voice. Its perceptual aspect has traditionally been used to evaluate diplophonia because the perceptions can be easily evaluated, but there are limitations in the validity of the reliability of the intra- and inter-raters, examination situation, and variation of voice sample. Therefore, the purpose of this study is to confirm the reliability and accuracy of auditory perceptual evaluation by comparing non-invasive indirect assessment methods (sound waveform and EGG analysis), and to identify their usefulness with diplophonia. A total of 28 diplophonic voices and 39 non-periodic voices were assessed. Three raters assessed the diplophonia by performing an auditory perception evaluation and identifying the quasi-periodic perturbations of the acoustic waveform and EGG. Among the three discrimination methods, intra- and inter-rater reliability, sensitivity, specificity, accuracy, positive likelihood ratio, and negative likelihood ratio were examined, and the McNemar test was performed to compare the discriminant agreement. The accuracy of the auditory perceptual evaluation (86.57%) was not significantly different from that of sound waveform acoustic (88.06%), but it was significantly different from that of EGG (83.33%). The reading time (6.02 s) for the auditory perceptual evaluation was significantly different from that for sound waveform analysis (30.15 s) and EGG analysis (16.41 s). In the discrimination of diplophonia, auditory perceptual evaluation has sufficient reliability and accuracy as compared to sound waveform and EGG. Since immediate feedback is possible, auditory perceptual evaluation is more convenient. Therefore, it can continue to be used as a tool to discriminate diplophonia in clinical practice.

An Experimental Study of Comfortable Pitch and Loudness with Target Matching: Effects on Electroglottographic and Acoustic Measures

  • 최성희
    • 말소리와 음성과학
    • /
    • 제4권4호
    • /
    • pp.139-146
    • /
    • 2012
  • This study was designed to examine comfort levels of pitch and loudness with target matching and their effects on electroglottographic (EGG) and acoustic measures. Twelve speakers, six males and six females, were instructed to produce /a/ sustained vowel for three seconds at a comfortable pitch and loudness level without any instruction and with a target matching procedure of either a certain f0 or SPL separately with visual and auditory feedback. The range of pitch for females and males were presented by progressing up and down randomly at intervals of 5Hz from 150 Hz to 310 Hz (total 33 frequency targets) and from 85 Hz to 190 Hz (total 22 frequency targets), respectively. The loudness levels were 65, 75, 85, 95 dB (total of four intensity targets) for both males and females. Subjective estimations of comfortable levels were obtained using a 10-point equal-appearing interval rating scale following each phonation. The results showed that males and females demonstrated similar trends in loudness levels with greatest comfort at 75 dB, whereas pitch comfort ratings showed a greater variability with females having a wider range with target matching. In the comfort levels of individuals, most male and female speakers rated higher comfort at soft, rather than loud phonations. On the other hand, most male speakers perceived highest comfort levels below the comfort pitch levels they phonated under natural conditions. Higher frequency ranges, however, were perceived to be more comfortable than those of natural condition in most female speakers, although the comfortable pitch levels in spontaneous phonations were within the comfort level ranges determined by targeted phonations. When comparing acoustic (%jitter, %shimmer, SNR) and EGG measures (CQ%) between spontaneous comfortable phonations and targeted phonations produced by the same subject at similar f0 and intensity, no significant differences were observed (p>0.05). Thus, target matching procedures may be considered a compatible and alternative method to reduce the variability of comfortable pitch and loudness levels by eliciting consistent comfortable phonations.

근피로를 유발하는 운동강도 변화가 슬관절의 위치감각 인지에 미치는 영향 (The Effect of Graded Exercise-Induced Fatigue on Position Sense of the Knee)

  • 이충휘;최종덕;이강노;이동률;최재명
    • 한국전문물리치료학회지
    • /
    • 제6권3호
    • /
    • pp.22-37
    • /
    • 1999
  • It was recently reported that exercise-induced fatigue is related to joint position sense although some controversy remains. The purposes of this study were to examine the effect on the accuracy of reproducing the knee angles after a fatiguing isokinetic quadriceps exercise at four different levels (10%, 30%, 50%, and 70% of maximal force) and to find the optimal exercise level without causing knee joint proprioception impairment. Forty healthy women, ages 19 to 27, were randomly assigned to four experimental groups. Before and after the exercise, accuracy of positioning with respect to auditory feedback for specific angles was estimated by calculating the mean errors between specific angles and reproduction angles. Fatigue was measured by EMG signals displayed by a frequency spectrum analysis during the quadriceps exercise. Results showed that there was no significant difference in accuracy of the knee joint positioning sense following the exercises in group 1, group 2, and group 3 (10%, 30%, and 50% of maximal force, respectively); the exception being group 4 (70%). Fatigue level was significantly increased in group 4 but there were no significant increases of fatigue level in group 1, group 2, or group 3. The results concluded that the optimal exercise level to acquire the therapeutic exercise effectiveness without position sense impairment was at 50% of maximal force. Further studies using large sample size and patient groups with poor knee joint proprioception would be needed to confirm this conclusion and to clarify the possibility of clinical applications.

  • PDF

한국어 시·청각 동음동철이의 어절 재인에 나타나는 어휘-의미 상호작용 (Lexico-semantic interactions during the visual and spoken recognition of homonymous Korean Eojeols)

  • 김준우;강귀영;유도영;전인서;김현경;남현민;신지영;남기춘
    • 말소리와 음성과학
    • /
    • 제13권1호
    • /
    • pp.1-15
    • /
    • 2021
  • 본 연구는 중의성을 가진 어휘가 심성 어휘집에 표상된 방식과 감각 양상에 따른 처리 과정을 알아보기 위하여 한국어 동음동철이의 어절의 시·청각 재인 과정을 조사하였다. 청각 어절 판단 과제(실험 1)와 시각 어절 판단 과제(실험 2)를 이용한 두 실험에서 두 가지 이상의 의미를 가진 동음동철이의 어절(예: '물었다')과 단일한 의미만을 가진 통제 어절(예: '고통을')이 사용되었다. 어절 자극들의 누적 빈도는 조작하는 한편, 각 동음동철이의 어절의 다양한 의미가 가지는 상대적 빈도는 통제하였다. 어절 판단 과제를 사용한 두 실험 모두에서 유의한 빈도의 주효과와 함께 의미 수에 따른 어절 유형과 빈도 간의 상호작용이 발견되었다. 실험 1에서 청각적으로 제시된 동음동철이의 어절은 저빈도 조건에서 단의 어절에 비해 반응시간이 빠른 중의성 이득 효과가 나타난 반면, 고빈도 조건에서는 이와 반대로 비이득 효과가 나타났다. 마찬가지로 시각적으로 제시된 실험 2의 자극에서도 유사한 상호작용 패턴이 발견되었다. 본 연구 결과는 시각 및 청각 양상 모두에서 어휘-의미 처리가 상호의존적으로 이루어짐을 보여주며, 이는 의미 처리가 감각 의존적 단계보다는 일반적 어휘 지식 처리 단계에서 이루어질 가능성을 시사한다. 이와 더불어 의미 선택 과정에서 동음동철이의 어절이 가지는 다양한 의미의 후보군은 어절의 빈도가 상대적으로 낮을 때에만 촉진적 피드백을 제공함을 보여준다.

이갈이 진단 및 조절용 구내장치의 개발과 신뢰도 조사 (Development and Reliability of Intraoral Appliance for Diagnosis and Control of Bruxism)

  • 김성원;김미은;김기석
    • Journal of Oral Medicine and Pain
    • /
    • 제30권1호
    • /
    • pp.69-77
    • /
    • 2005
  • 이갈이 치료에 가장 널리 이용되고 있는 구내교합장치는 치아와 턱관절 및 주위조직을 보호함으로써 이갈이 때문에 발생하는 여러 합병증을 예방하는 것을 주목적으로 하지만, 이갈이 억제에 있어서는 일시적인 증상감소의 효과만을 가질 뿐이므로 환자 스스로가 이갈이를 인지하여 습관을 중단할 수 있도록 하기 위한 특수한 장치의 개발이 시도되고 있다. 본 연구에서는 소형 방수 스위치를 이용하여 구내장치에 들어가는 부품을 최소화하고 전원의 사용시간을 최대화 함으로서 상품화 가능한 이갈이 진단 및 조절용 장치(이하 이갈이장치)를 개발하여 소개하고, 임상적으로 사용하기 전 장치에 대한 신뢰도를 조사하고자 하였다. 새로 개발한 장치는 이갈이 센서인 소형 방수스위치로 구성된 정보입력부, 중앙정보처리장치(CPU)인 정보처리부, 이갈이 신호를 수신하는 정보저장부, 이갈이 신호에 대한 소리나 진동으로 반응하는 반응장치부 및 컴퓨터상에서 저장된 이갈이 정보를 표시하여 이갈이 빈도와 시간, 양태 등을 확인시켜주는 정보표시부로 구성되어 있다. 이 중에서 resin sheet로 만든 상하의 wafer 사이에 정보입력부인 스위치는 좌우 견치 설면에 고정하고 정보처리부 CPU는 구개중앙에 고정하여 구내교합장치를 제작한 한편, 여기에서 송신되는 정보는 별도의 외부 장치인 반응장치 및 정보저장장치에서 인식하여 feedback을 보낼 수 있도록 하였다. 장치제작의 신뢰도조사를 위해서는 단국대학교 치과대학 학생 중 정상교합을 가진 지원자 10명의 상악 석고모형에 대하여 두 명의 술자가 각각 이갈이장치를 제작하여 그 장치가 반응하는 힘의 크기를 비교하였으며(술자간 신뢰도조사), 또한 한명의 술자가 첫 회에 조사한 정보를 기억하지 못하게 약 2일의 시간 간격을 두고 각각 제작하고 그 장치가 반응하는 힘의 크기를 비교하였다(술자내 신뢰도조사). 술자간 및 술자내 조사에서 이갈이장치가 반응하는 최소의 수직력, 측방력, 중심력에서 모두 높은 상관관계를 보였으며 측정된 값에 있어 서로 유의한 차이를 보여주지 않았다. 새로 개발한 이갈이장치는 부품을 소형화하였으며 제작이 편리하고 구강내에서 안전하게 사용할 수 있을 뿐만 아니라 전원의 사용시간을 최대로 할 수 있다는 장점을 가지고 있으며 술자간 및 술자내 신뢰도 조사를 통하여 임상에 적용가능한 높은 재현성을 확인할 수 있었다. 결론적으로 이 장치는 정보처리 및 저장장치가 있고 음향이나 진동을 이용한 바이오피드백 기능을 가지고 있어 이갈이 환자의 진단과 조절에 임상적으로 유용하게 사용될 수 있을 것으로 생각된다.

차동 전자 트랜스듀서를 이용한 이식형 인공중이 시스템의 실험적 검증 (Experimental Verification of Implantable Middle Ear System using the Differential Electromagnetic Type Transducer)

  • 송병섭;이기찬;원철호;박세광;이상흔;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권3호
    • /
    • pp.217-225
    • /
    • 2002
  • 이식형 인공중이는 일반적인 공기전도형 보청기가 가지는 난점인 고이득에서의 왜곡과 음향 피이드백에 의한 링잉 현상을 해결할 수 있는 동시에 음질과 주파수 특성 및 청음명료도가 우수하다 본 논문에서는 마이크로머시닝 기술을 이용하여 차동 전자 트랜스듀서를 제작한 후 이를 사용하여 이식형 인공중이 시스템을 구현하였다. 제작된 시스템을 이용하여 무부하 진동실험. 사체를 이용한 부하진동실험 및 살아있는 개를 이용하여 동물이식실험을 실시함으로써 이의 성능을 확인하였다. 무부하 진동실험을 통하여 제작된 트랜스듀서는 입력되는 소리신호와 같은 형태의 진동을 일으킴을 확인하였고, 사체의 이소골에 트랜스듀서를 이식하고 부하실험을 실시함으로써 트랜스듀서의 이소골 구동능력과 진동특성을 조사하였다. 그리고 개를 이용하여 동물이식실험을 실시한 후 뇌간 유발 반응검사를 실시함으로써 생체 내에서의 이식형 인공중이의 동작을 확인하였다. 이를 통하여 제작된 차동 전자 트랜스듀서를 이용한 이식형 인공중이 시스템의 성능을 검증하였고 난청자에게 적용할 경우에도 잘 동작할 수 있음을 증명함으로써 임상실험을 실시할 수 있는 근거를 마련하였다.