• Title/Summary/Keyword: Freezing risk

Search Result 40, Processing Time 0.024 seconds

Regional Distribution of Peach Freezing Damage and Chilling Days in 2010 in Gangwon Province (강원지역의 2010년 복숭아 동해)

  • Seo, Young-Ho;Park, Young-Sik;Cho, Byoung-Ouk;Kang, An-Seok;Jeong, Byeong-Chan;Jung, Yeong-Sang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.225-231
    • /
    • 2010
  • Extremely low values of the daily minimum temperature occurred in January 2010, ranging from -18 to $-29^{\circ}C$ at various locations growing peach trees in the Gangwon province. Due to the extreme cold temperature during the winter dormancy period of peach trees, the growth of the peach trees was damaged and the damaged areas increased as the extent of 17 to 144 ha. In order to provide information on mitigation measure of the cold temperature on the peach trees in the Gangwon province, we assessed the distribution of the damaged areas of growing the peach trees in 2010 and compared it with freezing risk estimated from the dormancy depth of the peach trees and the daily minimum temperature. The dormancy depth of 'Changhowon Hwando (Prunus persica (L.) Batsch)' ranged from -62 to -90 and the freezing risk was greater than 51%. The relationship between the freezing risk and the actual damaged area ratio showed reasonable agreement ($r^2$ of 0.5 with p < 0.01). The results imply that the estimates of the freezing risk based on the dormancy depth can be used as a mitigation measure to identify susceptible peach growing areas to freezing damage injury.

Geospatial Assessment of Frost and Freeze Risk in 'Changhowon Hwangdo' Peach (Prunus persica) Trees as Affected by the Projected Winter Warming in South Korea: II. Freezing Risk Index Based on Dormancy Depth as a Proxy for Physiological Tolerance to Freezing Temperature (겨울기온 상승에 따른 복숭아 나무 '장호원황도' 품종의 결과지에 대한 동상해위험 공간분석: II. 휴면심도로 표현한 생리적 내동성에 근거한 동해위험지수)

  • Kim, Jin-Hee;Kim, Soo-Ock;Chung, U-Ran;Yun, Jin-I.;Hwang, Kyu-Hong;Kim, Jung-Bae;Yoon, Ik-Koo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.4
    • /
    • pp.213-220
    • /
    • 2009
  • In order to predict the risk of freeze injury for 'Changhowon Hwangdo' peach trees, we used the dormancy depth (i.e., the daily chill unit accumulation during the overwintering period) as a proxy for the short-term, physiological tolerance to freezing temperatures. A Chill-days model was employed and its parameters such as base temperature and chilling requirement were optimized for peach trees based on the 12 observational experiments during the 2008-2009 winter. The model predicted the flowering dates much closer to the observations than other models without considering dormancy depth, showing the strength of employing dormancy depth into consideration. To derive empirical equations for calculating the probabilistic freeze risk, the dormancy depth was then combined with the browning ratio and the budburst ratio of frozen peach fruit branches. Given the exact date and the predicted minimum temperature, the equations calculate the probability of freeze damages such as a failure in budburst or tissue browning. This method of employing dormancy depth in addition to freezing temperature would be useful in locating in advance the risky areas of freezing injury for peach trees production under the projected climate change.

Development of an Anti-Freezing Heating Cable Temperature Controller and Its Power Saving Effects Analysis (동파방지 발열선용 온도제어기 개발 및 전기에너지 절감 효과 분석)

  • Lee, Kihong;Lee, Jaejin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.101-106
    • /
    • 2014
  • Although anti-freezing heating cable has been widely installed in most residential boiler pipe, there were excessive energy consumption and fire risk due to inadequate temperature control. In this paper, a new energy saving fire risk-free controller was developed by using microprocessing operation which include detection of not only boiler room temperature but also pipe surface one. Its actual effect has been verified to save more than a half of the energy consumption comparing to conventional controller through temperature and humidity chamber experiment.

A Study on Ignition and Fire Risks of Electric Heat Wire (전기적 열선의 발화 및 화재 위험성에 관한 연구)

  • Min, Se-hong;Song, Byeong-jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.

A Study on the development of big data-based AI water meter freeze and burst risk information service (빅데이터 기반 인공지능 동파위험 정보서비스 개발을 위한 연구)

  • Lee, Jinuk;Kim, Sunghoon;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.3
    • /
    • pp.42-51
    • /
    • 2023
  • Freeze and burst water meter in winter causes many social costs, such as meter replacement cost, inability of water use, and secondary damage by freezing water. The government is making efforts to modernize local waterworks, and in particular, is promoting SWM(Smart Water Management) project nationwide. In this study suggests a new freeze risk notification information service based on the temperature by IoT sensor inside the water meter box rather than outside temperature. In addition, in order to overcome the quantitative and regional limitation of IoT temperature sensors installed nationwide, and AI based temperature prediction model was developed that predicts the temperature inside water meter boxes based on data acquired from IoT temperature sensors and other information. Through the prediction model optimization process, a nationwide water meter freezing risk information service was convinced.

Experimental study on the applicability of liquid air as the refrigerant in artificial ground freezing for subsea tunnels (해저터널을 위한 동결공법 냉매로서의 액화공기 적용성에 대한 실험적 연구)

  • Son, Young-Jin;Choi, Hyeungchul;Moon, Hung-Man;Choi, Hangseok;Ko, Tae Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.2
    • /
    • pp.175-181
    • /
    • 2016
  • In this paper, the liquid air was selected as the refrigerant in artificial ground freezing to be used for rapid ground freezing and to reduce the risk of suffocation and the applicability of liquid air was verified. In order to evaluate the stability of the liquid air, the oxygen concentration of mixtures with liquid nitrogen and liquid oxygen was experimentally examined to meet the oxygen concentration criteria in the Occupational Safety and Health Act. In addition, the effects of the mixture ratio of liquid nitrogen and liquid oxygen, pressure and flow rate change in the storage vessel on the oxygen concentration in the liquid air were investigated. As a result, the ratio of liquid nitrogen and liquid oxygen 8: 2 was shown to meet the oxygen concentration standards. Pressure and flow rate change in the storage vessel did not have significant effects on the oxygen concentration in the liquid air.

Geospatial Assessment of Frost and Freeze Risk in 'Changhowon Hwangdo' Peach (Prunus persica) Trees as Affected by the Projected Winter Warming in South Korea: I. Determination of Freezing Temperatures (겨울기온 상승에 따른 복숭아 나무 '장호원 황도' 품종의 결과지에 대한 동상해위험 공간분석: I. 월동기간 중 동해유발온도 결정)

  • Chung, U-Ran;Kim, Jin-Hee;Kim, Soo-Ock;Choi, Mi-Hee;Hwang, Kyu-Hong;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.4
    • /
    • pp.206-212
    • /
    • 2009
  • We investigated the patterns of freeze injury in dormant 'Changhowon Hwangdo' peach fruit by observing the extent of browning and germination of the branches that were treated with freezing temperature sets simulating the process of natural freezing incidences in orchards. Under the treatment of freezing temperature of $-15^{\circ}C$, the browning ratios were 15% for flower bud and less than 3% for both leaf bud and cambium. Under the $-20^{\circ}C$ treatment, the browning ratios were 40% for both flower and leaf buds and 1% for cambium. The browning ratios were 86%, 68% and 40% respectively for flower bud, leaf bud, and cambium under the $-25^{\circ}C$ treatment. All the samples showed 100% browning ratio under the $-30^{\circ}C$ treatment. The budburst ratios of leaf buds were 85%, 66%, 32%, and 0% under the -15, -20, -25 and $-30^{\circ}C$ treatments, respectively. The branches of peach fruit treated with the same freezing temperature showed different responses depending on the sampling date. In January the browning ratio was low and the budburst ratio was high whereas in February the opposite was the case, showing vulnerability of peach trees to low temperature after endo-dormancy release.

Analysis of Dowel Bar Placement Accuracy with Construction Methods (시공방법에 따른 다웰바 시공상태 분석)

  • Lee, Jae-Hoon;Kim, Hyung-Bae;Kwon, Soon-Min;Kwon, Ou-Sun
    • International Journal of Highway Engineering
    • /
    • v.9 no.2 s.32
    • /
    • pp.101-114
    • /
    • 2007
  • Dowel bars in the jointed concrete pavement are used to both provide load transfer across pavements joints and prevent the joint faulting leading to longer service life. On the contrary, the misplacement of dowel bar can provide negative results including the joint freezing(locking) that may cause the joint spatting and unexpected mid-slab cracking. The dowel bar can be placed using the assembly or dowel bar inserter (DBI) during the concrete pavement construction. In the domestic practice of the concrete pavement construction, the dowel bar is placed using the assembly method. This study primarily focuses on the comparison of these two dowel placement methods using the field data from the KHC test road in which both dowel placement methods have been applied to a certain length of the concrete pavement. The field data regarding the alignment of the dowel bars placed by both methods was collected using MIT-SCAN2, a nondestructive measuring equipment, and processed to compute Joint Score and Running Ave. Joint Score which are used as indicators of the dowel bar performance. The comparison of the methods for the dowel bar placement using these indicators shows that the DBI method provided much better alignment of the dowel bars reducing the risk of joint freezing than the assembly method. In order to improve the quality of the dowel bar placement using the assembly method, the current weak points of the assembly method including the fabrication, storage, and installation of dowel bar assembly were investigated and the solution was suggested. The improved dowel bar sets based on the suggested solution have been applied to an actual practice of the concrete pavement construction. The field data shows that the improved assembly method suggested in this study can highly reduce the risk of joint freezing.

  • PDF

Cryopreservation of in vitro matured oocytes after ex vivo oocyte retrieval from gynecologic cancer patients undergoing radical surgery

  • Park, Chan Woo;Lee, Sun Hee;Yang, Kwang Moon;Lee, In Ho;Lim, Kyung Teak;Lee, Ki Heon;Kim, Tae Jin
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.43 no.2
    • /
    • pp.119-125
    • /
    • 2016
  • Objective: The aim of this study was to report a case series of in vitro matured (IVM) oocyte freezing in gynecologic cancer patients undergoing radical surgery under time constraints as an option for fertility preservation (FP). Methods: Case series report. University-based in vitro fertilization center. Six gynecologic cancer patients who were scheduled to undergo radical surgery the next day were referred for FP. The patients had endometrial (n=2), ovarian (n=3), and double primary endometrial and ovarian (n=1) cancer. Ex vivo retrieval of immature oocytes from macroscopically normal ovarian tissue was followed by mature oocyte freezing after IVM or embryo freezing with intracytoplasmic sperm injection. Results: A total of 53 oocytes were retrieved from five patients, with a mean of 10.6 oocytes per patient. After IVM, a total of 36 mature oocytes were obtained, demonstrating a 67.9% maturation rate. With regard to the ovarian cancer patients, seven IVM oocytes were frozen from patient 3, who had stage IC cancer, whereas one IVM oocyte was frozen from patient 4, who had stage IV cancer despite being of a similar age. With regard to the endometrial cancer patients, 15 IVM oocytes from patient 1 were frozen. Five embryos were frozen after the fertilization of IVM oocytes from patient 6. Conclusion: Immature oocytes can be successfully retrieved ex vivo from macroscopically normal ovarian tissue before radical surgery. IVM oocyte freezing provides a possible FP option in patients with advanced-stage endometrial or ovarian cancer without the risk of cancer cell spillage or time delays.

Necessity of Korean Integrated Life Safety Code and Fire Safety Performance Evaluation Technology (한국형 통합 인명안전코드 및 화재안전 성능평가기술의 필요성)

  • Kwon, Young-Jin;Koo, In-Hyuk;Jin, Seung-hyeon;Lee, Byeong-Heun;Kim, Yun-Seong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.50-51
    • /
    • 2020
  • Recently, construction projects are gradually becoming high-rise and large-scale, and furthermore, the use of new buildings is emerging through the deepening of the underground. In this situation, a lot of fire damage has occurred in recent years, mainly in buildings and tunnel structures. In particular, damages caused by fires during large-scale construction projects such as freezing warehouse accidents are increasing. In this situation, in Korea, it is still trying to secure safety from human fire through the administrative system divided into the building law and the fire law, but it is being developed in a negative direction rather than a positive direction. The fire risk is getting bigger even when the road is not maintained. In this current situation, it is considered that the development of a Korean integrated life safety code centering on the consciousness base of Koreans will be necessary, and in particular, the ease of revision will also be needed by promoting the integrated safety code rather than current laws and regulations. This is a summary of the future tasks.

  • PDF