• Title/Summary/Keyword: Freeze protection

Search Result 45, Processing Time 0.022 seconds

소방용 설비.기기 등의 동결방지 대책(1)

  • Lee, Bok-Yeong
    • Fire Protection Technology
    • /
    • s.11
    • /
    • pp.31-39
    • /
    • 1991
  • As the Present industry is developing, a structure and systems is tending increase. Therefore, the accident of freezing become intensified in our country, the continental climate zone of region in the middle degree. This paper is to analyze about the reason of freezing, principles to help avoid freeze, and so forth.

  • PDF

A Study on the Strength Properties and the Temperature Curve of Winter Concrete According to the Difference of Curing Method in Mock-up Test (실물부재시험에서의 양생방법 차이에 따른 한중콘크리트외 온도이력 및 강도특성에 관한 연구)

  • Kim, Young-Jin;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.541-548
    • /
    • 2003
  • This study is to investigate the temperature curve and development of compressive strength due to the curing conditions and to evaluate the optimum curing condition of test specimens showing the same development of strength to that of real structures in cold weather. The results of temperature curve with curing conditions in mock-up tests showed the trend of decrease plain concrete with insulation form, plain concrete with heating, concrete with accelerator for freeze protection, and control concrete in turn. The strength development of plain concrete of inside and outside of shelter showed the very slow strength gains due to early freezing, but that of concrete with accelerator for freeze protection showed the gradual increase of strength with time. From this, it is clear that accelerator for freeze protection has the effects of reducing the freezing temperature and accelerating the hardening under low temperature. Strength test results of small specimens embedded in members and located in insulation boxes at the site are similar to that of cores drilled from the members at the same ages, thus it is clear that these curing methods are effective for evaluation in-place concrete strength.

Compressive Strength and Fluidity of Low Temperature Curable Mortar Using High Early Strength Cement According to Types of Anti-freezer, Accelerator for Freeze Protection and Water Reducing Agent (조강형시멘트를 사용한 저온경화형 모르타르의 압축강도 및 유동특성에 미치는 방동제, 내한촉진제 및 감수제의 영향)

  • Park, Jung-Hoon;Ki, Kyoung-Kuk;Lee, Han-Seung;Kim, Hyeong-Cheol;Choi, Hyun-Kuk;Min, Tae-Beom
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.405-412
    • /
    • 2016
  • In order to examine the possibility of practical use of concrete at low-temperature environment using high early strength cement with cold resistance admixture, an experimental study on workability, freezing temperature and compressive strength of the mortar with different types of anti-freezer, water reducing agent and accelerator for freeze protection at low-temperature were evaluated. Compressive strength was increased in use of anti-freezer, especially SN anti-freezer was higher than CN anti-freezer. 0min flow was increased, the 20min flow was decreased. And 20min flow was improved in use of FR, RT water reducing agent. CF, LS accelerator for freeze protection, regardless of the type of water reducing agent, compressive strength was increased.

A Case Study of Electric Power Consumption Characteristics in University Building (대학건물의 에너지 소비 특성에 관한 사례분석)

  • Lee, Wang-Je;Lee, Dong-Won;Lee, Jae-Bum;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.90-95
    • /
    • 2012
  • Of school buildings, university building requires various case analysis unlike buildings in the elementary, middle and high schools in accordance with its characteristic for variables such as characteristic of department, construction structure and material, the number of persons admitted and schedule. Through the case research on the 'D' university located in Daejeon, this study made a comparison on the monthly and yearly consumption of gas and electricity of the most recent 3 years and implemented analysis on the usage pattern and standby power of air conditioning and heating by the hour and month using PCCS(Power Consumption Consulting System) as respects electricity that is considered to have a possibility of energy-saving. The result of analysis showed that enormous amount of electric power was used during the night time for freeze protection and burst in winter season and standby power was increased in winter season as a result.

A Case Study of Electric Power Consumption Characteristics in University Building (대학건물의 전력소비 특성에 관한 사례분석)

  • Lee, Wang-Je;Yoo, Jong-Ho;Baek, Nam-Choon;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.282-287
    • /
    • 2011
  • Of school buildings, university building requires various case analysis unlike buildings in the elementary, middle and high schools in accordance with its characteristic for variables such as characteristic of department, construction structure and material, the number of persons admitted and schedule. Through the case research on the 'D' university located in Daejeon, this study made a comparison on the monthly and yearly consumption of gas and electricity of the most recent 3 years and implemented analysis on the usage pattern and standby power of air conditioning and heating by the hour and month using PCCS(Power Consumption Consulting System) as respects electricity that is considered to have a possibility of energy-saving. The result of analysis showed that enormous amount of electric power was used during the night time for freeze protection and burst in winter season and standby power was increased in winter season as a result.

  • PDF

Numerical Analysis of Unsteady Heat Transfer for the Location Selection of Anti-freeze for the Fire Protection Piping with Electrical Heat Trace (소방 배관 동파방지용 열선의 위치 선정을 위한 비정상 열전달 수치해석)

  • Choi, Myoung-Young;Lee, Dong-Wook;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.52-57
    • /
    • 2014
  • In this paper, the unsteady incompressible Navier-Stokes equations coupled with energy equation were solved to find out the optimal location of electrical heat trace for anti-freeze of water inside the pipe for fire protection. Since the conduction equation of pipe was coupled with the natural convection of water, the analysis of conjugate heat transfer was conducted. A commercial code (ANSYS-FLUENT) based on SIMPLE-type algorithm was used for investigating the unsteady flows and temperature distributions in water region. From the numerical experiments, the isotherms and the vector fields in water region were obtained. Furthermore, it was found that the lowest part of the pipe cross-section was an optimal position of electrical heat trace assuming the constant thermal expansion coefficient of water since the minimum temperature of the water with the position is higher than those with the other positions.

Application of Cold Weather Concreting with Accelerator for Freeze Protection to Full Scale Structures (내한촉진제를 사용한 한중콘크리트의 실구조물 적용에 관한 연구)

  • Kim, Young-Jin;Baek, Tae-Ryong;Lee, Sang-Soo;Won, Chul;Kim, Dong-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.254-262
    • /
    • 2003
  • In this study, the results of applying cold weather concreting mixed with Accelerator for Freeze Protection(AFP) to full scale structures are presented. Since the determination of W/C and amount of AFP significantly have an effect on strength gain and protection of frost damage in early, a full investigation is needed to determine these values at stage of nux design. The flowability of fresh cold weather concreting with AFP was similar to the same W/C. Lower loss of workability and initial slump flow of concrete using superplasticizer of polycarboxylic ester than that of melamine sulphonate showed that polycarboxylic ester was more effective on elapsed time. Temperature histories of specimens located in insulation boxes at the site was similar to that of structures. Thus, it is cleared that simple adiabatic curing method is effective for evaluating in-place concrete strength than specimens cured by sealing method. The investigation results of development of compressive strength of cold weather concreting included AFP with curing methods by logistic curves indicated that AFP can be effective to gain strength at lower temperature than normal curing temperature. In field testing, vinyl sheets were placed over the concrete sections and AFP enabled concrete to gain $5N/{mm}^2$ to protect frost damage in early ages and specified compressive strength of concrete at 28 days under average temperature of $-2^{\circ}C$ (lowest temperature was $-12^{\circ}C$) during site application.

Frost resistance of porous concrete assuming actual environment (實環境を考慮したポーラスコンクリートの耐凍害性の評価(실제 환경을 고려한 다공질 콘크리트의 내동해성(耐凍害性) 평가))

  • NAKAMURA, Takuro;HORIGUCHI, Takashi;SHIMURA, Kazunori;SUGAWARA, Takashi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.227-233
    • /
    • 2008
  • Porous concrete has large continuous voids of 20-30 % by volume, and this concrete is attractive as environmental material in Japan i.e. permeable road pavement, river bank protection with vegetation and green roof system which influence thermal environment. It is necessary to confirm the frost resistance when constructing porous concrete structure in cold region. However applicable test method and evaluation criterion of porous concrete has not defined yet. Therefore, the object of this study is to investigate the frost resistance of porous concrete and this investigation attempts to address this concern by comparing 4 kinds of specified freezing and thawing tests methods (JIS A1148 procedure A/B and RILEM CIF/CDF test) in consideration of actual environment. RILEM freeze-thaw tests are different from JIS A1148 freeze-thaw tests, which are widely adopted for evaluating the frost resistance of conventional concrete in Japan, in water absorption, cooling rate, length of freezing and thawing period, and number of freezing and thawing cycles. RILEM CIF test measures internal damage and is primarily applicable for pure frost attack. CDF test is appropriate for freeze-thaw and de-icing salt attack. JIS A1148 procedure A/B showed extremely low frost resistance of porous concrete if the large continuous voids were filled with water and the ice expansion in the large continuous voids set in during cooling. Frost resistance of porous concrete was improved by mixing coarse aggregate (G7) which particle size is smaller and fine aggregate in JIS freezing and thawing tests. RILEM CIF/CDF test showed that freeze-thaw and de-icing resistance of porous concrete was seems to be superior in that of conventional concrete.

  • PDF

The Influence of Insulation Wraps on the Temperature Change of Kiwifruit Trunk Surface During Winter (월동 피복재 종류에 따른 참다래 주간부 표면 온도변화)

  • Kwack, Yong-Bum;Kim, Hong Lim;Kim, Seong-Cheol;Kim, Mok-Jong;Lee, Yong-Bok
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.4
    • /
    • pp.403-408
    • /
    • 2014
  • BACKGROUND: Kiwifruit is a warm-temperate, deciduous fruit tree. It is sensitive to frost or freeze damage during winter. Therefore, the farmers cover kiwifruit trunk with rice straw to preclude freeze injury. This study was conducted to evaluate trunk wraps for protection of freeze injury of kiwifruit (Actinidia deliciosa) vines. METHODS AND RESULTS: The experimental orchard was located in Sacheon (lat. $34^{\circ}56'N$, long. $128^{\circ}03'E$) of Gyeongsangnam-do, South Korea. The vines were 5-6-year-old 'Hayward'. Two wrap materials, rice straw and silver-cushioned mat (reflective foil-coated, plastic-foamed mat, Ganan Industry, Rep. of Korea) were evaluated for their heat-retaining ability. The trunks of kiwifruit vines were wrapped in late December, and the wraps were removed in mid-April the following year (2012/13 and 2013/14). Temperature inner wraps were recorded from January to March in 2013 and 2014 by WatchDog 2450 (Spectrum Technologies, Inc., USA). In 2013, the lowest ambient temperature of January and February was $-10.2^{\circ}C$, $-10.9^{\circ}C$, respectively. The lowest temperature of inner-wrap of silver -cushioned mat was $-6.3^{\circ}C$, $-2.6^{\circ}C$ in January and February, respectively. However, rice straw showed $-9.8^{\circ}C$ and $-9.9^{\circ}C$ in its lowest value of January and February. And also silver cushioned mat appeared to be superior to rice straw in its ability of heat-retaining during night time.

Cryo- and Thermo-protective Effects of Enzymatically Synthesized $\beta$-Galactosyl Trehalose Trisaccharide

  • Kim, Bong-Gwan;Ryu, Soo-In;Lee, Soo-Bok
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.199-202
    • /
    • 2008
  • The effects of $\beta$-(1,6)-galactosyl trehalose trisaccharide ($\beta$-GT) that was preferentially produced by Escherichia coli $\beta$-galactosidase on cryo- and thermo-protections of protein were investigated with those of other sugars at the level of 8% (w/v). As compared to a control without sugar additive, $\beta$-GT effectively enhanced 32-54% of the cryoprotection of fish actomyosin against repeated freeze-thawing and frozen storage, and also 49% of the protection against thermal inactivation of pyrophosphatase, respectively. As a result, it was significantly more effective than sorbitol and trehalose in both cryoprotection and thermoprotection. Thus, $\beta$-GT would be possibly applied as a sugar substitute for cryo- and thermo-protective applications of food protein.