• 제목/요약/키워드: Free electron laser

검색결과 72건 처리시간 0.031초

펨토초 레이어 기반 유리 내부가공 특성 (Characteristic of the femtosecond laser machining in glass)

  • 유병헌;김영미;조성학;장원석;김재구;황경현;이동주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.239-240
    • /
    • 2006
  • For longer than picosecond pulses, bulk damage inside defect-free dielectrics involves the heating and multiplication of spurious electrons by the incident laser beam and transfer of this energy to the lattice. The situation is quite different for femtosecond pulses which are shorter than the time scale for electron energy transfer to the lattice. Damage caused by these pulses is produced with smaller statistical uncertainty and is controllable on a microscopic scale. These properties can be exploited to produce laser devices such as arrays of damage dots for all optical memories with high data storage density or arrays of parallel grooves to form transmission gratings. In this work, we observed characteristic of the femtosecond laser machining in BK7 and fused silica.

  • PDF

Vacuum system for PAL-XFEL

  • 나동현;하태균;박종도
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.110.2-110.2
    • /
    • 2016
  • 4세대 방사광가속기는 0.1nm급 X-선 자유전자레이저(X-ray Free Electron Laser : XFEL) 광원을 빔라인 사용자들에게 제공하기 위하여 2011년 건설을 시작하였고, 2015년부터 장치를 설치하기 시작했으며 현재 건설 완료단계에 이르러 있다. 이 장치에서 진공시스템은 10-11 mbar의 초고진공이 요구되는 전자빔 발생장치인 RF Gun을 포함하는 입사장치구간(Injector)과 전체길이 800 m에 이르는 전자빔을 가속시키는 선형가속기구간(Linac) 그리고 결맞음 방사광을 발생시키는 언듈레이터구간으로 나눌 수 있다. 본 논문에서는 각 구간별 진공시스템에 대한 건설 현황에 대하여 보고하고자 한다.

  • PDF

Preliminary Radiological Considerations for X-ray Free Electron Laser Project at PAL

  • Lee, Hee-Seock;Hong, Suk-Mo;Kim, Min-Ho
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2004년도 추계학술발표회 발표논문집
    • /
    • pp.1190-1191
    • /
    • 2004
  • New $4^{th}$ generation synchrotron facility, XFEL, is almost similar to previous $3^{rd}$ generation synchrotron facility in the view of radiological aspects and most important positions are a dump and synchrotron radiation beam line. In this paper, tile radiation protection solutions for them and undulator are suggested and discussed.

  • PDF

프라즈마 이용기술 (1)

  • 황기웅
    • 전기의세계
    • /
    • 제34권8호
    • /
    • pp.470-475
    • /
    • 1985
  • 우주물질의 대부분이 플라즈마 상태에 있지마는 지구상에서는 천둥이 칠 때 생기는 방전이나 극지방에서 볼 수 있는 오로라와 같이 극히 일부분이 자연상태의 프라즈마로 존재한다. 지금까지 플라즈마의 이용은 그것이 내는 밝은 빛을 이용한 조명이나, 높은 열을 이용한 용접이나 절단이 고작이었으나, 최근에 들어 초고온, 고밀도 플라즈마를 이용한 핵융합 에너지 연구나 Free Electron Laser나 Gyrotron과 같이 새로운 Radiation Source로써 종래의 Source가 만들지 못하던 주파수 영역이나 Glow Discharge에서 생기는 저온 Plasma를 이용한 Plasma Etching PECVD(Plasma Enhanced CHemical Vapor Deposition), Plasma Ashing, Sputtering등은 VLSI의 제조에 필요불가결한 공정의 일부분이 되고 있다. 앞으로 수회에 걸쳐 본 기술해설란을 통하여 이들 Plasma의 이용 기술을 소개하고자 하며 본회에서는 그중에서 Plasma Etching에 대해서 그 원리와 기술상의 특징을 살펴보고자 한다.

  • PDF

Growth of zinc oxide thin films by oxygen plasma-assisted pulsed laser deposition

  • Pak, Sang-Woo;Suh, Joo-Young;Lee, Dong-Uk;Kim, Eun-Kyu
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.208-208
    • /
    • 2010
  • Zinc oxide (ZnO) is a functional material with interesting optical and electrical properties, a wide band gap (more than 3.3 eV), a high transmittance in the visible light region, piezoelectric properties, and a high n-type conductivity. This material has been investigated for use in many applications, such as transparent electrodes, blue light-emitting diodes, and ultra-violet detector. ZnO films grown under low oxygen pressure by thin film deposition methods show low resistivity and large free electron concentration. Therefore, reducing the background carrier concentration in ZnO films is one of the major challenges ahead of realizing high-performance ZnO-based optoelectronic devices. In this study, we deposited ZnO thin films on sapphire substrates by pulsed laser deposition (PLD) with employing an oxygen plasma source to decrease the background free-electron concentration and enhance the crystalline quality. Then, the substrate temperature was varied between 200 'C to 900 'C The vacuum chamber was initially evacuated to a pressure of $10^{-6}$ Torr, and then a pure $O_2$ gas was introduced into the chamber and the pressure during deposition was maintained at $10^{-2}$ Torr. Crystallinity and orientation of ZnO films were investigated by X-ray diffraction (XRD). The film surface was analyzed with atomic force microscope (AFM). And electrical properties were measured at room temperature by Hall measurement.

  • PDF

CO2레이저 조사후 상아질 조직변화에 대한 주사전자혐기경적 연구 (A SCANNING ELECTRON MICROSCOPIC STUDY OF HUMAN DENTIN SURFACE WITH THE CO2 LASER IRRADIATION)

  • 최동훈;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.106-120
    • /
    • 1991
  • The main purpose of this study was to investigate the possibility of obstruction of dentinal tubules through irradiation of the $CO_2$ laser on the dentin surface. For this study, 104 extracted caries - free premolars and molars were grinded their mesial or distal surface to expose dentin completly. And these specimens were divided into three Groups. Group I : those with their smear layer not removed and Group IT : those with their smear layer removed, were irradiated by the $CO_2$ laser(SPACE LASER - $CO_2$ VEGA 25) at five different energy levels ranging 4 - 20J/$cm^2$, and all specimens were observed with scanning eletron microscope (Hitachi S - 450). Group m was divided into 2 sub - groups: one with smear layer, another one without and those were irradiated with $CO_2$ laser of the same condition as Group I & II. All specimens were immersed in, $37^{\circ}C$, 0.5% methylene blue solution for 48 hours after 100 times of thermocycling at $4^{\circ}C$ and $60^{\circ}C$, and were observed with stereo -light microscope (Olympus SZH - ILLD) to evaluate dye penetration. The following results were obtained; 1. The dentinal tubules were obstructed through laser irradiation. 2. The dentinal tubules were still obstructed after treatment of 10% HCl/2sec., then it was proved that acid resistance of detin surface was also increased. 3. The Group of laser irradiation showed less dye penetration than control Group. 4. The smear layer hardly affected obstruction of the dentinal tubules through laser irradiation.

  • PDF

Nd:YAG 레이저조사가 치경부 백악질에 미치는 영향에 관한 주사전자현미경적 연구 (A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Cervical Cementum)

  • 최복;이정연;신금백
    • Journal of Oral Medicine and Pain
    • /
    • 제25권4호
    • /
    • pp.415-425
    • /
    • 2000
  • In order to obtain the basic data concerning the optimal lasing conditions in using Nd:YAG laser as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum, the author selected 36 human teeth having no cervical abrasion and caries (; 12 anteriors, 12 premolars. 12 molars) extracted due to periodontal diseases, and divided them into 4 groups as Group I, II, III and IV (; each group of 3 anteriors, 3 premolars, 3 molars), and prepared a cementum specimen with thickness of $1.0mm{\pm}0.2mm$ sectioned longitudinally at the middle of mesio-distal thickness (; Group I) or horizontally at 1mm-2mm below the cemento-enamel junction (; Group II, III, IV) from each tooth of each group by low speed diamond wheel saw, and treated them with 0.5 M ethylene diamine tetraacetic acid (; EDTA, pH=7.4) for 2 minutes for elimination of remnants during tooth-sectioning. And the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (; wavelength 1064nm. pulse duration $120{\mu}sec$, fiber diameter $320{{\mu}m}$) to cementum surfaces in triplicates of one experiment under the following lasing conditions: 1. stationary mode of fiber in contact to cementum surfaces without air-spray (; Group I )/with air-spray (; Group II), 2. unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec without air-spray (; Group III)/with air-spray (; Group IV), 3. energy per pulse (mJ/pulse) [; energy density ($J/cm^{2}$)] in order of 1.0W/10Hz (100J/pulse); $124J/cm^{2}$, 0.5W/10Hz (50mJ/pulse); $62J/cm^{2}$, 0.4W/10Hz (40mJ/pulse); $50J/cm^{2}$, 0.3W/10Hz (30mJ/pulse); $37J/cm^{2}$, 4. exposure time of 1 second. And the author applied the platinum coating on surfaces of cementum specimens, and evaluated the characteristics of ultrastructural change on surfaces of cementum using the scanning electron microscopy. In general the ultrastructural loss of cervical cementum irradiated under the same lasing condition of laser energy density occurred least in specimens of Group IV. And especially, the ultrastructural loss of cervical cementum irradiated under the laser energy density of $37J/cm^{2}$ almost did not occur in specimens of Group IV. Therefore, it is considered that the pulsed Nd:YAG laser should be applied with the lasing conditions of unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec with air-spray and of laser energy density within $37J/cm^{2}$ as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum.

  • PDF

Measurement of Relativistic Electron Beam Propagation with Localized Plasma Channel

  • 최명철
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.242-242
    • /
    • 1999
  • 상대론적 전자빔 발생장치(300kV, 40kA, 60ns)를 통하여 발생하는 전자빔은 진공 중에서 공간전하한계전류값을 갖게 되어 진행이 어렵다. 이런 전자빔의 전파특성을 향상시키기 위하여 여러 가지 방법들이 실험되어졌다. 본 실험실에서 수행한 실험은 전자빔의 진행해나가는 도파관 속에 국부적인 plasma channel을 형성시키고 이에 따른 전자빔의 전파율의 향상을 유도하였다. 이때 형성되는 높은 에너지의 이온빔을 관찰하고 이온 전류밀도에 따른 전자빔의 수송효율사이의 관계를 관찰하였다. 전류밀도의 증가는 여러 가지로 응용 될 수 있다. 자유전자레이저(Free Electron Laser)는 microwave로부터 가시광선 영역을 포함해 X-ray 영역까지의 coherent radiation을 발생시킬 수 있는 개념의 장치이다. 이 장치에서 전자빔의 전류밀도는 출력되는 전자기파의 power와 직접적으로 관계하여 고출력 microwave 발생장치를 구성할 수 있다. 이번 실험에서는 일정한 국부적으로 형성된 plasma에 따른 강렬한 상대론적 전자빔의 전파효율의 향상을 관찰하였다.

  • PDF

PAL-XFEL 빔라인 허치 구조물 개발 (The Development of Beamline Hutch Structures at PAL-XFEL)

  • 김승남;김명진;김성한;김영찬;신호철;김지화;김경숙;김광우;엄인태
    • 한국소음진동공학회논문집
    • /
    • 제26권5호
    • /
    • pp.567-577
    • /
    • 2016
  • The hutches which are installed in the beamline are largely classified into two, i.e XPP (X-ray pump probe) and CXI (Coherent X-ray image). Laser room is installed on the hutch and provides laser to XPP and CXI simultaneously. And two hutches have heavy crane to install some optics equipments. Safety and reliability of hutch structures should be taken into account for the precise operating of the laser facilities, so vibration analysis is essential to do this. The main purpose of vibration analysis is to install hutch structures with large stiffness. We have changed materials specification several times to install hutch structures having strong stiffness. Now hutch structures were installed and checked vibration status at laser room and XPP hutch. The results of laser table and robot arm satisfy vibration criteria. This paper explains about the design and vibration analysis of hutch structures.