• 제목/요약/키워드: Free cooling

검색결과 264건 처리시간 0.02초

Characteristics of Thermo-Acoustic Emission from Composite Laminates during Thermal Load Cycles

  • Kim, Young-Bok;Park, Nak-Sam
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.391-399
    • /
    • 2003
  • The thermo-acoustic emission (AE) technique has been applied for nondestructive characterization of composite laminates subjected to cryogenic cooling. Thermo-AE events during heating and cooling cycles showed a Kaiser effect. An analysis of the thermo-AE behavior obtained during the 1st heating period suggested a method for determining the stress-free temperature of the composite laminates. Three different thermo-AE types classified by a short-time Fourier transform of AE signals enabled to offer a nondestructive estimation of the cryogenic damages of the composites, in that the different thermo-AE types corresponded to secondary microfracturing in the matrix contacting between crack surfaces and some abrasive contact between broken fiber ends during thermal load cycles.

중장비 팬의 엔진룸을 통한 소음방사 해석 (Noise Radiation Analysis of the Cooling Fan in a Heavy Equipment)

  • 정기훈;전완호;이덕주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.954-960
    • /
    • 2001
  • Axial fans are widely used in heavy machines due to their ability to produce high cooling of engines. At the same time. the noise generated by these fans causes or serious problems. This work is concerned with the low noise technique of discrete. The prediction model. which allowed the calculation of acoustic pressure at the frequency and it's harmonics, has been developed by Farrasat and the Helmholtz-Kir. The newly developed Helmholtz-Kirchhoff BEM for thin body is used to calculate the sound field of the fan that is located in a engine room. To calculate the unsteady resultant force over blade. Time-Marching Free-Wake Method are used. The fan noise of fan sys unsymmetric engine-room is predicted. In this paper. the discussion is confined to and discrete noise of axial fan and front Part of engine room in heavy equipments.

  • PDF

저온 수직평판에서 착상에 대한 운전조건의 영향 (The Effect of Operating Conditions on the Frost Formation in a Vertical Plate at a Low Temperature)

  • 이관수;이태희;김우승
    • 대한기계학회논문집
    • /
    • 제18권12호
    • /
    • pp.3305-3314
    • /
    • 1994
  • In this study, the influence of a frost formed on the vertical plate for different operating conditions(the temperature of the air, the humidity of the air, the velocity of the air, and the temperature of the cooling plate) is investigated. The performance of the heat exchanger is examined by introducing a parameter such as the energy transfer resistance. Correlations which relate frost density, frost thickness and energy transfer resistance to Reynolds number, air temperature and humidity, and cooling plate temperature are developed. Static pressure drop and air flow rate are expressed as a function of free flow area of air.

Temperature Dependent Self-Diffusion Coefficients of Valinomycin and the Potassium-Valinomycin Complex

  • Kim, Su-Deuk;Lee, Yun-Jung;Joo, Hyun-Hye;Ahn, Sang-Doo
    • 한국자기공명학회논문지
    • /
    • 제12권1호
    • /
    • pp.51-59
    • /
    • 2008
  • Convection effect in liquids has been one of the main targets to be overcome in pulsed-field-gradient NMR measurements of self-diffusion coefficients since the temperature gradient along the sample tube generated by the heating and/or cooling process causes the effect, resulting in additional diffusion. It is known that the capillary is the most appropriate tube type for diffusion experiments at variable temperatures since the narrower tube suppresses convection effectively. For evaluating the properties of hydrogen bonding, diffusion coefficients of the $K^+$-complexed and free valinomycin in a micro tube have been determined at various temperatures. From the analysis of the obtained diffusion coefficient values, we could conclude that the intramolecular hydrogen bonding in both of the $K^+$ complexed and free valinomycin in a non-polar solvent is preserved over the observed temperature range, and the temperature dependence of hydrogen bonding is more pronounced in free valinomycin. It is also thought that there is no big change in the radius of the $K^+$-complexed as temperature is varied, and the ratio of overall radius, $r_{complex}/r_{free}$ is slightly decreased as temperature rises.

자유 체적이론을 고려한 급냉 폴리스티렌판에 발생하는 잔류응력과 복굴절 형성에 관한 연구 (A Study on the Prediction of Thermally-Induced Residual Stress and Birefringence in Quenched Polystyrene Plate Including Free Volume Theory)

  • 김종선;윤경환
    • 대한기계학회논문집A
    • /
    • 제27권1호
    • /
    • pp.77-87
    • /
    • 2003
  • The residual stress and birefringence in injection-molded plastic parts can be divided into the flow-induced residual stress and birefringence produced in flowing stage, the thermally-induced residual stress and birefringence produced in cooling stage. However, the physics involved in the generation of the thermally-induced residual stress and birefringence still remains to be understood. Because polymer experiences viscoelastic history near the glass-transition temperature it is hard to model the entire process. Volume relaxation phenomenon was included to predict the final thermally-induced residual stress and birefringence in quenched plastic parts more accurately. The present study focused on comparing the predicted values far thermally-induced residual stress and birefringence with and without volume relaxation behavior (or free volume theory) under free and constrained quenching conditions. As a result, tile residual stress remained as a tensile stress at the center and as a compressible stress near the surface for the free quenching cases. In contract the residual stress remained as a compressible stress at the center and as a tensile stress near the surface fur the constrained quenching cases. The residual birefringence remained as minus values at the center and as plus values near the surface for the free quenching cases. Interestingly the residual birefringence showed minus values in entire zone for the constrained quenching cases. In the prediction of birefringence only the case including free volume theory showed the correct result for the distribution of birefringence in thickness direction.

A New Protocol for Effective Cryopreservation of Human Embryonic Stem Cells by a Minimum Volume Cooling Method

  • Kim, Eun-Young;Lee, Keum-Sil;Shin, Hyun-Ah;Park, Sae-Young;Yoon, Ji-Yeon;Kil, Kwang-Soo;Lee, Young-Jae;Kim, Nam-Hyung;Chung, Kil-Saeng
    • 한국발생생물학회:학술대회논문집
    • /
    • 한국발생생물학회 2003년도 제3회 국제심포지움 및 학술대회
    • /
    • pp.98-98
    • /
    • 2003
  • Recently, human embryonic stem (hES) cells have become very important resources for ES cell basic research, cell replacement therapy, and other medical applications; thus, efficient cryopreservation methods for these cells are needed. This study examined whether a newly developed minimum volume cooling (MVC) vitrification method, which was tested through cryopreservation of sensitive bovine oocytes, can be used for freezing hES cells. Feeder-free cultured hES cell (MB03) colonies were mechanically dissected into several small clumps following enzymatic treatment. We compared the freezing efficiency of a slow-cooling method using a cryo-module (0.4-0.6C/min, 20-30 clumps/vial) and MVC vitrification using a modified 0.5-ml French mini-straw designated as a MVC straw (>$20,000{\circ}C$/min, 10 clumps/straw) After thawing, in vitro survival of hES cell clumps was higher for MVC-vitrified cells (80.8%, 97/120) than for slow-cooled cells (38.2%, 39/102). Further, the proliferation rate of surviving MVC-vitrified cells was similar to that of control hES cells from 2 weeks after thawing. In addition, vitrified-thawed hES cells demonstrated a normal karyotype, were positively immunostained for surface marker antibodies (AP, SSEA-4 and TRA-1-60) and the Oct-4 antibody, and could differentiate into all three embryonic germ layer cells in vitro. This result demonstrates that hES cell clumps can be successfully cryopreserved by a newly developed MVC vitrification method without loss of human cell characteristics.

  • PDF

대형 풍력발전기 부품의 극한 환경 시험을 위한 극저온 챔버의 열유동 해석에 대한 연구 (STUDY ON THE THERMAL-FLUID ANALYSIS OF CRYOGENIC CHAMBER FOR COLD CLIMATE TEST OF LARGE WIND TURBINE PARTS)

  • 김민규;강율호;박원규
    • 한국전산유체공학회지
    • /
    • 제20권3호
    • /
    • pp.8-14
    • /
    • 2015
  • More and more, spaces are decreasing which satisfy multiple requirements for wind power plants. However, areas which have excellent wind resources and are free to civil complaints occupy a large space, although they are exposed to the cryogenic environment. This study conducted a thermal-fluid analysis of a cryogenic chamber for testing large wind turbine parts exposed to the cryogenic environment. The position of supply air is placed to the upper area to compare each cooling performance for each location of various outlets in mixing ventilated conditions. The study carried out CFD analysis for the chamber both with and without a test object. For the cases without the test object, the air temperature of the upper supply and down extract type chamber was cooled faster by 5-100% than the others. However, for the cases with the test object, the object temperature of upper supply and center extract on the opposite side type chamber was cooled faster by 33-132% than the others. The cooling performance by the air inside the chamber and the test object did not show the same pattern, which implicates the need to consider the cooling performance by not only the air but also the test object in the large cryogenic chamber design for testing large parts.

히트싱크의 자연대류 열유동 특성 분석 (Investigation of Natural Convective Heat Flow Characteristics of Heat Sink)

  • 정태성;강환국
    • 대한기계학회논문집B
    • /
    • 제37권1호
    • /
    • pp.27-33
    • /
    • 2013
  • 제품의 성능 및 신뢰성 향상을 위하여 효과적이고, 적정한 방열장치의 중요성이 지속적으로 부각되고 있다. 현재 가장 널리 쓰이는 방열장치는 알루미늄 압출식 평행핀 형상의 히트싱크(heat sink)로 이의 설계를 위해서는 방열량과 최대 허용온도 등에 대한 목표가 결정되어야 하며, 사용 환경 및 설치 방법에 따른 열전달 계수의 예측이 이루어져야 한다. 본 연구에서는 히트싱크의 베이스가 수직, 수평상태를 유지함에 따라 나타나는 핀 주변의 자연대류 유동 특성을 전산모사 해석을 통해 고찰하였다. 또한, 일반적인 자연대류형 히트싱크를 대상으로 수평 및 수직상태에서의 열적 성능 실험을 수행하였으며, 기존의 연구결과와 비교함으로써 설치방향이 히트싱크 방열성능에 미치는 영향에 대하여 분석하였다. 실험결과 수평상태의 경우는 수직인 경우에 비하여 약 10~15% 열전달 계수의 감소가 발생하였다.

REBa2Cu3O7-x (RE=Nd, Gd, Dy) 초전도체의 열처리에 따른 상변태와 미세구조 (Phase Transformation and Misconstruct of REBa2Cu3O7-x (RE=Nd, Gd, Dy) Superconductor during Heat treatment)

  • 오용택;한용희;한병성;한상철;성태현;홍광준;신동찬
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1278-1285
    • /
    • 2003
  • This study investigated the phase transformation of the REBa$_2$Cu$_3$$O_{7-x}$ (RE=Nd, Gd, Dy) superconductor, and CCT (Continuous-Cooling-Transformation) along with the TTT (Time-Temperature-Transformation) diagrams are suggested according to the isothermal and continuous cooling heat-treatments. The peritectic temperature of the 123 phases decreased approximately 3$0^{\circ}C$ when the ionic radius of the rare-earth elements was reduced. The optimum cooling rate where BC and Cu-free phases do not exist was 0.001$^{\circ}C$/s. At this cooling late, the 123 phase grew with a c-axis Perpendicular to the surface and had a well-distributed 211 phase. When the oxygen partial pressure was reduced Outing isothermal heat-treatment, the formation temperature of the 211 phase decreased. In addition, the formation temperature of the 123 phases decreased from 100$0^{\circ}C$ (Nd-123) to 9$25^{\circ}C$ (Gd-123), and finally 875$^{\circ}C$ (Dy-123) according to the decrease in the ionic radius of the tare-earth elements. Compared to Nd-123, Gd- and Dy-123 had a better texture with a well-distributed 211 phase.e.

기획특집 - 초고층 설비설계사례 (HVAC System For Highriser Residential Bilding)

  • 노석남
    • 기술사
    • /
    • 제42권5호
    • /
    • pp.32-36
    • /
    • 2009
  • This project located in IFEZ(Incheon Free Economic Zone) is the first central heating and cooling type for high-rise residential building in korea. The design was performed as the joint venture between Cosentini from U.S.A and wooowon, and our design concept was to save energy. LEED application from USGBC is going on in progress for the first residential building in korea. Careful attention was paid from schematic design for not a durability of structural and architectural, but also durability and safety of M.E.P.

  • PDF