• Title/Summary/Keyword: Frame Images

Search Result 772, Processing Time 0.023 seconds

An Adaptive Algorithm for the Quantization Step Size Control of MPEG-2

  • Cho, Nam-Ik
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.6
    • /
    • pp.138-145
    • /
    • 1997
  • This paper proposes an adaptive algorithm for the quantization step size control of MPEG-2, using the information obtained from the previously encoded picture. Before quantizing the DCT coefficients, the properties of reconstruction error of each macro block (MB) is predicted from the previous frame. For the prediction of the error of current MB, a block with the size of MB in the previous frame are chosen by use of the motion vector. Since the original and reconstructed images of the previous frame are available in the encoder, we can calculate the reconstruction error of this block. This error is considered as the expected error of the current MB if it is quantized with the same step size and bit rate. Comparing the error of the MB with the average of overall MBs, if it is larger than the average, small step size is given for this MB, and vice versa. As a result, the error distribution of the MB is more concentrated to the average, giving low variance and improved image quality. Especially for the low bit application, the proposed algorithm gives much smaller error variance and higher PSNR compared to TM5 (test model 5).

  • PDF

A Synchronized Stereo Image Acquisition on the Optical Tracker (Optical Tracker에서 좌우 적외선 영상의 동시 획득에 관한 연구)

  • 신동익;허수진
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.527-534
    • /
    • 2001
  • Conventional stereo image acquisition uses a pair of frame grabbers in the CAS(Computer Assisted Surgery) system. In this Paper, we developed a synchronized stereo image acquisition method with only one frame grabber Two images from left and right camera each other. were merged with different color space without time delay and thus only one frame grabber was enough toy stereo image. Due to this synchronous Property of image acquisition, we can improve spatial revolution on the computation of 3D Position. Furthermore the overall costs for 3D navigator can be down and the extraction time of stereo Position tan be shortened.

  • PDF

An Efficient On-line Frame Scheduling Algorithm for Video Conferences (화상회의를 위한 효율적인 온-라인 프레임 스케줄링 알고리즘)

  • 안성용;이정아;심재홍
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.7
    • /
    • pp.387-396
    • /
    • 2004
  • In this paper, we propose an algorithm that distributes processor time to the tasks decoding encoded frames with a goal maximizing total QoS (quality of services) of video conference system. An encoded frame has such a characteristic that the QoS of recovered frame image also increases as the processor time given for decoding the frame gets to increase. Thus, the quality of decoded image for each frame can be represented as a QoS function of the amount of service time given to decode. In addition, every stream of video conference has close time-dependency between continuous frames belonging to the same stream. Based on the time-dependency and QoS functions, we propose an on-line frame scheduling algorithm which does not schedule all frames in the system but just a few frames while maximizing total QoS of video streams in the conference. The simulation results show that, as the system load gets to increase, the proposed algorithm compared to the existing EDF algorithm can reduce the quality of decoded frame images more smoothly and show the movements of conference attendees more naturally without short cutting.

Improvement of Frame Rate of Electro-Optical Sensor using Temporal Super Resolution based on Color Channel Extrapolation (채널별 색상정보 외삽법 기반 시간적 초해상도 기법을 활용한 전자광학 센서의 프레임률 향상 연구)

  • Noh, SangWoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.120-124
    • /
    • 2017
  • The temporal super resolution is a method for increasing the frame rate. Electro-optical sensors are used in various surveillance and reconnaissance weapons systems, and the spatial resolution and temporal resolution of the required electro-optical sensors vary according to the performance requirement of each weapon system. Because most image sensors capture images at 30~60 frames/second, it is necessary to increase the frame rate when the target moves and changes rapidly. This paper proposes a method to increase the frame rate using color channel extrapolation. Using a DMD, one frame of a general camera was adjusted to have different consecutive exposure times for each channel, and the captured image was converted to a single channel image with an increased frame rate. Using the optical flow method, a virtual channel image was generated for each channel, and a single channel image with an increased frame rate was converted to a color channel image. The performance of the proposed temporal super resolution method was confirmed by the simulation.

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

Toward a Key-frame Extraction Framework for Video Storyboard Surrogates Based on Users' EEG Signals (이용자 기반의 비디오 키프레임 자동 추출을 위한 뇌파측정기술(EEG) 적용)

  • Kim, Hyun-Hee;Kim, Yong-Ho
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.49 no.1
    • /
    • pp.443-464
    • /
    • 2015
  • This study examined the feasibility of using EEG signals and ERP P3b for extracting video key-frames based on users' cognitive responses. Twenty participants were used to collect EEG signals. This research found that the average amplitude of right parietal lobe is higher than that of left parietal lobe when relevant images were shown to participants; there is a significant difference between the average amplitudes of both parietal lobes. On the other hand, the average amplitude of left parietal lobe in the case of non-relevant images is lower than that in the case of relevant images. Moreover, there is no significant difference between the average amplitudes of both parietal lobes in the case of non-relevant images. Additionally, the latency of MGFP1 and channel coherence can be also used as criteria to extract key-frames.

Interframe Coding of 3-D Medical Image Using Warping Prediction (Warping을 이용한 움직임 보상을 통한 3차원 의료 영상의 압축)

  • So, Yun-Sung;Cho, Hyun-Duck;Kim, Jong-Hyo;Ra, Jong-Beom
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.223-231
    • /
    • 1997
  • In this paper, an interframe coding method for volumetric medical images is proposed. By treating interslice variations as the motion of bones or tissues, we use the motion compensation (MC) technique to predict the current frame from the previous frame. Instead of a block matching algorithm (BMA), which is the most common motion estimation (ME) algorithm in video coding, image warping with biolinear transformation has been suggested to predict complex interslice object variation in medical images. When an object disappears between slices, however, warping prediction has poor performance. In order to overcome this drawback, an overlapped block motion compensation (OBMC) technique is combined with carping prediction. Motion compensated residual images are then encoded by using an embedded zerotree wavelet (EZW) coder with small modification for consistent quality of reconstructed images. The experimental results show that the interframe coding suing warping prediction provides better performance compared with interframe coding, and the OBMC scheme gives some additional improvement over the warping-only MC method.

  • PDF

The Application of Dynamic Acquisition with Motion Correction for Static Image (동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정)

  • Yoon, Seok-Hwan;Seung, Jong-Min;Kim, Kye-Hwan;Kim, Jae-Il;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame${\times}$30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.

  • PDF

An Algorithm for Collecting Traffic Information by Vehicle Tracking Method from CCTV Camera Images on the Highway (고속도로변 폐쇄회로 카메라 영상에서 트래킹에 의한 교통정보수집 알고리즘)

  • Lee In Jung;Min Joan Young;Jang Young Sang
    • Journal of Information Technology Applications and Management
    • /
    • v.11 no.4
    • /
    • pp.169-179
    • /
    • 2004
  • There are many inductive loop detectors under the highways in Korea. Among the other detectors, some are image detectors. Almost all image detectors are focused one or two lane of the road and are measuring traffic information. This paper proposes to an algorithm for detecting traffic information automatically from CCTV camera images installed on the highway. The information which is counted in one lane or two contains some critical errors by occlusion frequently in case of passing larger vehicles. In this paper, we use a tracking algorithm in which the detection area include all lanes, then the traffic informations are collected from the vehicles individually using difference images in this detection area. This tracking algorithm is better than lane by lane detecting algorithm. The experiment have been conducted two different real road scenes for 20 minutes. For the experiments, the images are provided with CCTV camera which was installed at Kiheung Interchange upstream of Kyongbu highway, and video recording images at Chungkye Tunnel. For image processing, images captured by frame-grabber board 30 frames per second, 640${\times}$480 pixels resolution and 256 gray-levels to reduce the total amount of data to be Interpreted.

  • PDF

Highly Dense 3D Surface Generation Using Multi-image Matching

  • Noh, Myoung-Jong;Cho, Woo-Sug;Bang, Ki-In
    • ETRI Journal
    • /
    • v.34 no.1
    • /
    • pp.87-97
    • /
    • 2012
  • This study presents an automatic matching method for generating a dense, accurate, and discontinuity-preserved digital surface model (DSM) using multiple images acquired by an aerial digital frame camera. The proposed method consists of two main procedures: area-based multi-image matching (AMIM) and stereo-pair epipolar line matching (SELM). AMIM evaluates the sum of the normalized cross correlation of corresponding image points from multiple images to determine the optimal height of an object point. A novel method is introduced for determining the search height range and incremental height, which are necessary for the vertical line locus used in the AMIM. This procedure also includes the means to select the best reference and target images for each strip so that multi-image matching can resolve the common problem over occlusion areas. The SELM extracts densely positioned distinct points along epipolar lines from the multiple images and generates a discontinuity-preserved DSM using geometric and radiometric constraints. The matched points derived by the AMIM are used as anchor points between overlapped images to find conjugate distinct points using epipolar geometry. The performance of the proposed method was evaluated for several different test areas, including urban areas.