• Title/Summary/Keyword: Fracture type

Search Result 1,283, Processing Time 0.03 seconds

A Comparative Study of Interlocking IM Nailing and LCP Fixation through MIPPO Technique in the Treatment of Distal Metaphyseal Tibial Fracture (경골 원위부 골절 치료에서 최소 침습적 접근법을 통한 잠금 나사 금속판 고정술과 교합성 골수강 내 금속정 고정술의 비교 연구)

  • Lee, Chang-Soo;Suh, Jin-Soo;Kim, Ji-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.80-85
    • /
    • 2008
  • Purpose: To evaluate and compare the outcome between interlocking IM nailing and LCP fixation in the treatment of distal metaphyseal tibial fracture. Materials and Methods: From January 2000 to December 2007, 17 patient were treated by interlocking IM nail and 13 patient were treated by LCP fixation for distal metaphyseal tibial fracture. Results: According to AO classification, there were 2 type A1 fracture (12%), 6 type A2 fracture (36%), 3 type A3 fracture (18%), 4 type B1 fracture (24%), 1 type B3 fracture (6%), 1 type C1 fracture (6%) in interlocking IM nailing group and 1 type A2 fracture (7.7%), 2 type A3 fracture (15.4%), 3 type B1 fracture (23%), 3 type B2 fracture (23%), 3 type C1 fracture (23%), 1 type C2 fracture (7.7%) in LCP fixation group. The clinical functional outcome (according to AOFAS score) is 75.6 point in IM nailing group and 81.5 point in LCP fixation group. In IM nailing group, 65% of patient showed satisfactory result and In LCP fixation group, 77% of patient showed satisfactory result. Conclusion: There is no difference on clinical results between IM nailing and MIPPO (minimal invasive percutaneous plate osteosynthesis) group in the treatment of distal tibia fracture. But MIPPO group have higher subjective satisfactory score and less complication rate. The weakness of our study is a small case number and limited follow-up and we believe a better designed prospective study will be needed.

  • PDF

Objective Outcomes of Closed Reduction According to the Type of Nasal Bone Fracture

  • Kang, Chang Min;Han, Dong Gil
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.1
    • /
    • pp.30-36
    • /
    • 2017
  • Background: Nasal fractures have a tendency of resulting in structural or functional complications, and the results can vary according to the type of nasal bone fracture. The aim of this study was to evaluate the objective postoperative results according to the type of nasal bone fractures. Methods: We reviewed 313 patients who had a closed reduction of nasal bone fracture. The classification of nasal bone fracture by Stranc and Robertson was used to characterize the fracture type: frontal impact group type I (FI), frontal impact group type II (FII), lateral impact group type I (LI), lateral impact group type II (LII), and comminuted fracture group (C). For each patient, we tried to use the same axial image section of computed tomographic (CT) scans before and immediately after operation. Postoperative outcomes were classified into 4 grades: excellent (E), good (G), fair (F), and poor (P). We also analyzed postoperative complications by fracture type. Results: Regarding the postoperative CT images, 189 subjects showed E results, 99 subjects showed G, 18 subjects showed F, and 7 subjects showed P reduction. The rate of operation results graded as E by each fracture type was 66.67% in FI, 52.0% in FII, 64.21% in LI, 62.79% in LII, and 21.74% in C. Complications of FI (7.14%), LII (13.95%), and C (13.04%) groups occurred more than in the FII (4.00%) and LI (4.21%) groups. Conclusion: It seems that the operation result by fracture type was better in the FI, LI, and LII type than the FII and C type; after one month, however, LII type showed more complications than other types. The septal fracture can be thought to affect early reduction results in nasal bone fractures.

Is All Anterior Oblique Fracture Orientation Really a Contraindication to Anterior Screw Fixation of Type II and Rostral Shallow Type III Odontoid Fractures?

  • Cho, Dae-Chul;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.345-350
    • /
    • 2011
  • Objective : It is debatable whether an anterior oblique fracture orientation is really a contraindication to anterior odontoid screw fixation. The purpose of this study was to investigate the feasibility of anterior odontoid screw fixation of type II and rostral shallow type III fracture with an anterior oblique fracture orientation. Methods : The authors evaluated 16 patients with type II and rostral shallow type III odontoid fracture with an anterior oblique fracture orientation. Of these 16 patients, 8 (group 1) were treated by anterior odontoid screw fixation, and 8 (group 2) by a posterior C1-2 arthrodesis. Results : Of the 8 patients in group 1, seven patients achieved solid bone fusion (87.5%), and one experienced screw back-out of the C-2 body two months after anterior screw fixation. All patients treated by posterior C1-C2 fusion in group 2 achieved successful bone fusion. Mean fracture displacements and fracture gaps were not significantly different in two groups. (p=0.075 and 0.782). However, mean fracture orientation angles were $15.3{\pm}3.2$ degrees in group 1, and $28.6{\pm}8.1$ degrees in group 2 (p=0.002), and mean fragment angulations were $3.2{\pm}2.1$ degrees in group 1, and $14.8{\pm}3.7$ degrees in group 2 (p=0.001). Conclusion : Even when the fracture lines of type II and rostral shallow type III fractures are oriented in an anterior oblique direction, anterior odontoid screw fixation can be feasible in carefully selected patients with a relatively small fracture orientation angle and relatively small fragment angulation.

Comparison of implant component fractures in external and internal type: A 12-year retrospective study

  • Yi, Yuseung;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Shin-Jae;Heo, Seong-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.155-162
    • /
    • 2018
  • PURPOSE. The aim of this study was to compare the fracture of implant component behavior of external and internal type of implants to suggest directions for successful implant treatment. MATERIALS AND METHODS. Data were collected from the clinical records of all patients who received WARANTEC implants at Seoul National University Dental Hospital from February 2002 to January 2014 for 12 years. Total number of implants was 1,289 and an average of 3.2 implants was installed per patient. Information about abutment connection type, implant locations, platform sizes was collected with presence of implant component fractures and their managements. SPSS statistics software (version 24.0, IBM) was used for the statistical analysis. RESULTS. Overall fracture was significantly more frequent in internal type. The most frequently fractured component was abutment in internal type implants, and screw fracture occurred most frequently in external type. Analyzing by fractured components, screw fracture was the most frequent in the maxillary anterior region and the most abutment fracture occurred in the maxillary posterior region and screw fractures occurred more frequently in NP (narrow platform) and abutment fractures occurred more frequently in RP (regular platform). CONCLUSION. In external type, screw fracture occurred most frequently, especially in the maxillary anterior region, and in internal type, abutment fracture occurred frequently in the posterior region. placement of an external type implant rather than an internal type is recommended for the posterior region where abutment fractures frequently occur.

Classification of the Lateral Orbital Wall Fracture and Its Clinical Significance (안와 외벽 골절의 분류와 임상적 의의)

  • Cho, Pil Dong;Kim, Hyung Suk;Shin, Keuk Shun
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.553-559
    • /
    • 2008
  • Purpose: The lateral orbital wall fractures have been previously classified by some authors. As there are some limitations in applying in their own classifications, we hope to present a refined classification system of the lateral orbital wall fracture and to identify the correlation between the specific type of the fracture and clinical diagnosis. Methods: The facial bone CT scans and medical records of 78 patients with the lateral orbital wall fractures were reviewed in a retrospective manner. The classification is based on the CT scan. In type I, the fracture and its segments are away from the lateral rectus muscle and in type II, they are next to or slightly pushing the muscle in axial CT scan. In type III, the fracture segments compress and displace the longitudinal axis of the muscle or the optic nerve in axial view of CT scan. Type IV fracture includes multiple fractures found around the orbital apex or optic canal in coronal view of CT scans of the type I and type II fractures. Results: The most common fracture pattern was type I(43.6%), followed by type IV(29.5%), type II(20.5%), and type III(6.4%). As diplopia and restriction of extraocular muscles were found in type I and II fractures, severe ophthalmic complications such as superior orbital fissure syndrome, orbital apex syndrome, and traumatic optic neuropathy were found in type III and IV fractures almost exclusively. Conclusion: We propose an easy classification system of the lateral orbital wall fracture which correlates closely with ophthalmic complications and may help to make further treatment plan. In Type III and IV fractures, severe ophthalmic complications may ensue in higher rates, so early diagnosis and treatment should be performed.

A Study on Fatigue Behavior according to Effective Case Depth in Induction Case Hardened SM45C Steel (고주파표면경화한 SM45C 강에서 유교경화층깊이가 피로거동에 미치는 영향)

  • 오세욱;호정원;박원조
    • Journal of Ocean Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.71-80
    • /
    • 1991
  • This paper reveals the effect of the effective case depth(ECD) on the fatigue behavior of a high-frequency induction hardened SM45C in rotated bending fatigue test. In addition, the effects of fracture modes(surface origin type, inner origin type) on it are discussed. The fatigue limit of the induction hardened steel is remarkably increased compared with that of base metal. In addition, the fatigue limit is linearly increased as the effective casedepth grows deep in the region of this experiment (ECD/R;0.23-0.49). The S-N curve and fracture mode in the induction case hardened steel are classified into two kinds, as a result : N$_{f}$<10$^{5}$ ;surface origin type fracture(at high stress), N$_{f}$>10$^{5}$ ; in ner origin type fracture(at low stress). In case of inner origin type fracture; as the effective case depth(ECD) gets deep, the fatigue limit is increased by the reason that the fracture origin moves toward center; in reverse, is decreased by reason that the compressive residual stress gets low. As a result, the increasing effect of the former is much bigger than the decreasing effect of the latter, and the fatigue limit is increased as the ECD gets deep.eep.

  • PDF

Correlation between Operation Result and Patient Satisfaction of Nasal Bone Fracture

  • Kang, Chang Min;Han, Dong Gil
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.1
    • /
    • pp.25-29
    • /
    • 2017
  • Background: Many authors have evaluated the post-reduction result of nasal bone fracture through patient satisfaction or postoperative complications. However, these results are limited because they are subjective. The aim of this study was to correlate an objective operation result with patient satisfaction and postoperative complications according to the type of nasal bone fractures. Methods: Our study included 313 patients who had isolated nasal bone fractures and had undergone a closed reduction. Postoperative outcomes were evaluated objectively using computed tomographic (CT) images, while patient satisfaction was evaluated one month after the operation. The correlation of the operation result with patient satisfaction was then evaluated. Results: The correlation between the operation result and patient satisfaction was highest for the lateral impact group type I (LI) type of fracture and lowest for the comminuted fracture group (C) type of fracture. However, there were no statistically significant differences in correlation between the overall result and patient satisfaction by fracture type. The complication rate of lateral impact group type II (LII), C, and frontal impact group type I (FI) fractures were statistically significantly higher than that of frontal impact group type II (FII) and LI fractures. There were no statistically significant relationships between the prevalence of complications and septal fracture or deviation according to the fracture type. In the total group, however, there was a statistically significant difference in complication rate by septal fracture. Conclusion: We found that the CT outcomes correlated with patient satisfaction. The complication rate of LII, C, and FI fractures were statistically significantly higher than that of FII and LI fractures. Septal fracture/deviation increased the postoperative complication in the total group.

Anterior Screw Fixation of Type II Odontoid Fracture (제 II 형 치상돌기 골절에서 전방경유 나사못 고정술)

  • Kim, Myung-Jin;Hwang, Jeong-Hyun;Sung, Joo-Kyung;Hwang, Sung-Kyu;Hamm, In-Suk;Park, Yeun-Mook;Kim, Seung-Lae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1461-1468
    • /
    • 2000
  • Objective : The aim of this study is to evaluate clinical outcome of anterior screw fixation for type II odontoid fractures for the prliematim of atlanatoaxial mobility. Methods : Between 1995 and 1999, we treated 15 cases of type II odontoid fractures by anterior screw fixation among 44 cases of odontoid fractures. Thece included 14 males and 1 female aged from 23 to 63 years, with a mean age of 39.7 years. The causes of trauma were traffic accident in 13 cases, slip down in 1 and fall down in 1. The fracture type was type II-P in 7 cases, type II-A in 3, type II-N in 2 and type II-A and P in 3. The fracture line was oblique downward and backward in 6 cases, oblique downward and forward in 3 and horizontally in 6. The range of follow up was 4 to 47 months(mean 26.5 months). Results : Adequate reduction and fixation were obtained in 12 cases. Three cases in which fracture type and line were type II-A and oblique downward forward were failed, so posterior transarticular screw fixation was performed. All except 3 failed cases had adequate cervical movement and stability. There were no operative mortality nor morbidity. Conclusion : Anterior screw fixation provides the best anatomical and functional results for type II odontoid fracture with intact transverse ligament when fracture line is horizontal or oblique downward and backward. But it is limited when fracture line is oblique downward and forward.

  • PDF

A Study on the Influence of Fiber Orientation on the Mode I Interlaminar Fracture Behavior of Carbon/Epoxy Composite materials (탄소섬유/에폭시 복합재료의 Mode I 층간파괴거동에 미치는 섬유배향각의 영향에 관한 연구)

  • 이택순;최영근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.391-401
    • /
    • 1995
  • Several tests of the Double Cantilever Beam(DCB) were carried out for influence of the fiber orientation on the Mode I of the interlaminar fracture behavior in the Carbon/Epoxy composites. The interlaminar fracture toughness of Mode I was estimated based on the energy release rate of Mode I, $G_{I}$. The fracture toughness at crack initiation, $G_{IC}$, increases from type A to type E. The fracture toughness, $G_{IR}$ , is almost constant macroscopically for type A and type E when crack propagates. $G_{IR}$ for types B, C, D increases rapidly at the beginning of the crack growth then it decreases gradually. The fracture surface observation by SEM was also obtained the same results. Consequently the influence of the fiber orientation on the Mode I Interlaminar fracture behavior was made clear.ear.

Anterior Screw Fixation using Herbert Screw for Type II Odontoid Process Fractures

  • Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.5
    • /
    • pp.345-349
    • /
    • 2005
  • Objective: Anterior screw fixation provides the best anatomical and functional results for type II odontoid process fracture (type II-A, II-N, and II-P) with intact transverse ligament. The purpose of this study is to evaluate the usefulness of the 4.5mm diameter, cannulated Herbert screw in anterior screw fixation. Methods: From Jan. 2003 to Feb. 2004, consecutive 10cases of type II odontoid process fractures were treated with anterior screw fixation using a Herbert screw. The Herbert screw has double threads, with different pitches on the distal and proximal ends. It has no head, so it can be inserted through articular cartilage and buried below bone surface. It was originally developed for treating scaphoid fractures. Results: There were 8male and 2female patients whose ages ranged from 15 to 67years (mean 42.1years). The fracture type was type II-A in 4patients, II-N in 3 patients, and II-P in 3 patients. The fracture line was oblique downward and backward in 6cases, oblique downward and forward in 1 case, and horizontal in 3cases. The range of follow-up was 5 to 18months (mean 12months). Bone fusions were achieved in all cases without any instrumental failures or postoperative complications. Conclusion: The Herbert screw is very useful in anterior fixation for type II odontoid process fracture. This series showed successful results also in type II-A odontoid fracture when treated with the Herbert screw, but further more studies are required.