• Title/Summary/Keyword: Fracture toughness

Search Result 1,697, Processing Time 0.029 seconds

THE EFFECT OF SURFACE FINISHES ON FLEXURAL STRENGTH, FRACTURE TOUGHNESS OF FELDSPATHIC DENTAL PORCELAIN

  • Chang, Il-Sung;Lee, Sun-Hyung;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.293-305
    • /
    • 2005
  • Statement of problems. Conventional feldspathic porcelain is used extensively as a restorative material and it is subjected to grinding and polishing during fabrication and delivery procedures. There is still considerable controversy concerning the best methods to achieve the strongest porcelain restorations after such adjustments. Purpose. The objective of this study was to investigate the effects of (1) overglazing, (2) selfglazing, and (3) fine polishing on the flexural strength and fracture toughness of feldspathic dental porcelain. Material and method. Ninety porcelain disks were prepared for flexural strength test and sixty porcelain disks were fabricated for fracture toughness test. Specimens were divided into three groups for each test as follows: 1) overglazed 2) self-glazed 3) polished. The flexural strength of feldspathic porcelains was determined by ring-on-ring biaxial flexural strength test. The fracture toughness values of three experimental groups were obtained by indentation fracture toughness test. Results. The flexural strength of overglazed group was significantly higher than that of selfglazed and polished group (P<0.05), while the difference between self-glazed and polished group was not significant (P>0.05). The fracture toughness values of overglazed and polished group were significantly higher than that of self-glazed group (P<0.05), while the difference between overglazed and polished group was not significant (P>0.05). Conclusions. This results supported the use of polishing as an alternative to glazing metal ceramic restorations, as it was not detrimental in flexural strength and fracture toughness. But, under the conditions of this study, overglazing was the ideal surface finishing method of feldspathic dental porcelain.

THE PHYSICAL PROPERTIES OF REUSED IPS EMPRESS CERAMIC PART IV : HARDNESS AND FRACTURE TOUGHNESS (반복 사용된 IPS Empress ceramic의 물리적 성질에 관한 연구 Part IV : 경도 및 파괴인성에 관한 연구)

  • Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.532-537
    • /
    • 2003
  • Statement of the problem : IPS Empress ceramic has been used as one of a esthetic restorative material since it's development, but the broad application of IPS Empress ceramic to clinical prosthodontic field has been limited by its high material cost. Purpose : This study was investigated to evaluate the hardness and fracture toughness after recycling of the IPS Empress ceramic. Material and methods : Reused specimens of IPS Empress were fabricated with repeated pressing. The hardness(Vickers hardness) and fracture toughness of 1st, 2nd and 3rd pressed specimens were measured with Digital Micro Hardness Tester(Model MXT70, Matsuzawa Seiki Co., Ltd, Tokyo, Japan). The obtained data were analyzed using SPSS(Ver 9.5). Result : The mean value of the hardness in the 1st, 2nd and 3rd pressed Empress were $6.23{\pm}0.48MPa,\;5.50{\pm}0.25MPa$, and $5.70{\pm}0.42MPa$. The hardness of the 1st pressing ceramic was higher than those or the 2nd and 3rd pressed ceramics(P<0.05). Hardness of the 3rd pressed ceramic was greater than that of the 2nd pressed ceramic. but there was no significant difference of hardness between those two(P>0.05). The mean value of the fracture toughness was $1.71{\pm}0.16MPam^{1/2}$ in 1st pressed ceramic, $1.78{\pm}0.10MPam^{1/2}$ in 2nd pressed and $1.73{\pm}0.14MPam^{1/2}$ in 3rd pressed IPS ceramic. Fracture toughness of the 2nd pressed ceramic was the highest and that of the 1st pressed ceramic was the lowest. There was no significant difference of fracture toughness among them(P>0.05). Conclusion : Hardness of the 2nd and 3rd pressed IPS Empress ceramics were lesser than that of 1st pressed IPS Empress ceramic(P<0.05), but there was no significant changes of fracture toughness among them(P>0.05).

Evaluation of Fracture Toughness Using Small Punch Test for Aluminum 6061-T6 Type-3 Cylinder Liner (소형펀치시험법을 이용한 알루미늄 6061-T6 Type-3 용기 라이너의 파괴인성 평가)

  • Ma, Young-Wha;Lee, Seong-Hoon;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.4
    • /
    • pp.21-26
    • /
    • 2011
  • Type-3 cylinder liner has a limitation of machining the standard specimen for fracture toughness test because it has approximately 5 mm in thickness as well as a curvature. Hence, it needs to be employed a miniature specimen test technique to evaluate fracture toughness of the cylinder liner. In this study, small punch (SP) test method was employed to evaluate fracture toughness of the cylinder liner. Load-displacement curve result measured from the SP test showed that the liner material was failed during membrane stretching in the general SP load-displacement curve. Additionally, it was shown that liner material was isotropic although the amount of plastic deformation was different depending on the direction due to manufacturing process characteristics. Fracture toughness, $J_{Ic}$, was evaluated using the SP test data. The value of fracture toughness obtained was $13.0kJ/m^2$. This value was similar to that of the same kind of materials. Therefore, the fracture toughness evaluated using the SP test data was reasonable.

A Study on the Correlations Between Ultrasonic Parameters and Fracture Toughness (초음파 파라미터와 파괴인성치의 상관관계에 관한 연구)

  • Kim Jeong-Pyo;Park Jae-Sil;Bae Bong-Kook;Seok Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.2 s.233
    • /
    • pp.232-238
    • /
    • 2005
  • In this study the four classes of the thermally aged 1Cr-1Mo-0.25V specimens were prepared using an artificially accelerated aging method. Ultrasonic tests were performed to get the correlation with fracture toughness. The modified theoretical Vary's equation, considering nonlinear response due to material degradation, was proposed for the correlations between ultrasonic parameters and fracture toughness. Experimental results indicate that ultrasonic attenuation coefficient, velocity and nonlinear parameters produce the correlations with fracture toughness and yield strength.

A Study on the Nondestructive Evaluation of Material Properties (비파괴적인 재료물성치 평가에 관한 연구)

  • Kim Hyung-Ick;Kim Jeong-Pyo;Seok Chang-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.130-136
    • /
    • 2005
  • The nondestructive evaluation system consisted of a ball indentation tester and a ultrasonic tester was developed to evaluate material properties. The relations between the parameters from test results using the system and the results of tensile and fracture toughness tests were investigated. The fracture toughness and tensile properties could be determined using the system. Some metallic materials were experimented to predict the fracture toughness and tensile properties and verify the relations between them. The predicted fracture toughness and tensile properties show a good agreement with the results obtained by conventional tests. It is found that the material properties and the material degradation can be evaluated using the nondestructive evaluation system.

Effects of Specimen Size in Evaluation of Elastic-Plastic Fracture Toughness by Ultrasonic Method (초음파법을 이용한 탄소성 파괴인성치 평가에 있어서 시험편 크기의 영향)

  • 강동명;함경춘;우창기
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.19-24
    • /
    • 1998
  • Elastic-plastic fracture toughness($J_{IC}$) by ultrasonic method is evaluated in terms of width and thickness. Widths of specimen in 6061-T6 aluminum alloy are 50mm and 100mm, thicknesses of those are 20mm and 25mm, respectively. Elastic-plastic fracture toughness by ultrasonic method is independent of specimen thickness and side groove. Angle beam probe which are placed on the end of the compact specimen detect the maximum crack extension effectively. Comparing with elastic-plastic fracture toughness by ultrasonic method and that of unloading compliance method, $J_{IC}$ of ultrasonic method are underestimated to that of unloading compliance method. Elastic-plastic fracture toughness of width 100mm specimen are underestimated to that of width 50mm specimen about 20%.

  • PDF

Directional Effect of Applied Pressure during the Sintering on the Microstructures and Fracture Toughness of Heat-treated Silicon Nitride Ceramics (소결시의 가압방식이 열처리 후 질화규소의 미세조직과 파괴인성에 미치는 영향)

  • 이상훈;박희동;이재도
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.6
    • /
    • pp.653-658
    • /
    • 1995
  • Directional effect of applied pressure during sintering on the microstructure and fracture toughness of the heat-treated silicon nitride ceramics has been investigated. The specimens with a composition of 92Si3N4-8Y2O3(in wt%) were sintered at 172$0^{\circ}C$ by a hot press (HP ) and a hot isostatic press (HIP) and heat-treated for grain growth at 1800~20$0^{\circ}C$. The fracture toughness of the HP samples increased with the grain size while the fracture toughness of the HIP treated samples remained the same even though the grain growth occurred. This discrepancy was explained by a bimodal grain size distribution and large aspect ratio of the HPed samples and a monomodal grain size distributjion and samll aspect ratio of the HIP treated samples.

  • PDF

Interlaminar Fracture Toughness of CFRP Laminate Plates by Resin Content (CFRP 적층판의 수지함량이 층간파괴인성치에 미치는 영향)

  • 강태식;김지훈;심재기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.675-678
    • /
    • 2001
  • In this paper, an investigation was performed on the dynamic interlaminar fracture toughness of CFRP(carbon fiber reinforcement plastics). Specimens used in this experiment are CF/EPOXY laminated plates. In this experiments, Split Hopkinson s Bar test was applied to dynamic and notched flexure test. The mode II fracture toughness of each unidirectional CFRP was estimated by the analyzed deflection of the specimen and J-integral with the measured impulsive load and reactions at the supported points. As an experimental result, the vibration amplitude of 〔$0_{10}F_4/0_{10}$〕laminates appear more than that of 〔0_{10}/F_2/0_{10}$〕laminates for the J-integral and displacement velocity at a measuring point. Also, it is thought that the dynamic fracture toughness of two kind specimen with the increase of displacement velocity becomes great at a measuring point with in range of measurement.

  • PDF

A Study on the Compliance of a Compact Tension Test Specimen (소형인장시험편의 컴플라이언스에 관한 고찰)

  • Jeong, Gi-Hyeon;Seok, Chang-Seong;Yang, Won-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.12
    • /
    • pp.3010-3017
    • /
    • 2000
  • For integrity evaluation of cracked or damaged structures, fracture toughness test results in ASTM are widely used. The fracture toughness values of the structures are used as an effective design criterion in nuclear plants and aircraft structures. Sometimes the difference of P-$\delta$ curve trend during the unloading /reloading cycle in the fracture toughness test using partial unloading compliance was observed. The phenomenon as a possible source of error in determining fracture toughness may be caused by the residual stress during unloading work-hardening and bucking of a specimen. Therefore, we evaluate the effect of bucking and compressive residual stress during the K-R and J-R testing using a finite element method.

Dynamic Crack Initiation of 17-4PH Casting Steel for Various Notch Radius (다양한 노치 반경을 갖는 17-4PH강의 동적균열개시 특성)

  • 박성욱;김덕회;김재훈;문순일
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.160-163
    • /
    • 2003
  • In this study, intrinsic dynamic fracture toughness of 17-4PH casting steel is evaluated from the apparent dynamic fracture toughness of notched specimen. Notch radius of notched specimen is manufactured from 0.1mm to 4mm. The results shows that dynamic fracture toughness decreases with decreasing of notch root radius above critical notch roof radius. The true dynamic fracture toughness can be predicted from test results of apparent dynamic fracture toughness measured by using notched specimen.

  • PDF