• 제목/요약/키워드: Fracture defect

검색결과 272건 처리시간 0.033초

Treatment of a Traumatic Leptomeningeal Cyst in an Adult with Fibrinogen-Based Collagen

  • Kim, Hoon;Jo, Kwang Wook
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권5호
    • /
    • pp.300-302
    • /
    • 2013
  • Reports of traumatic leptomeningeal cysts (TLMC) are rare in adults. The standard treatment approach is craniectomy with careful exposure of the intact dural edges, followed by duroplasty. However, occasionally, the location of the TLMC makes achieving watertight duroplasty impossible. Herein, we report the case of a 28-year-old male who presented with a soft growing mass on the vertex of his head 16 months after the head trauma. Upon enhanced CT examination, a bony defect involving both the inner and outer table of the cranium was observed close to the sagittal sinus, and a well-defined cystic mass, 5 cm in diameter, was nested within the defect. The risks associated with extension craniotomy were high because the lesion was located superficial to the sagittal sinus, we opted to use fibrinogen-based collagen fleece (TachoCombR$^{(R)}$) to repair the dural defect. Two months after surgery, the patient remained asymptomatic with a good cosmetic result. In cases like ours, when the defect is near the major sinuses and the risk of rupturing the sinus during watertight dural closure is high, fibrinogen-based collagen fleece (TachoCombR$^{(R)}$) is an effective alternative approach to standard dural suture techniques.

유한요소 해석을 이용한 나노임프린트 가압 공정에서 발생하는 결함 원인에 대한 연구 (A Study on Cause of Defects in NIL Molding Process using FEM)

  • 송남호;손지원;김동언;오수익
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 추계학술대회 논문집
    • /
    • pp.364-367
    • /
    • 2007
  • In nano-imprint lithography (NIL) process, which has shown to be a good method to fabricate polymeric patterns, several kinds of pattern defects due to thermal effects during polymer flow and mold release operation have been reported. A typical defect in NIL process with high aspect ratio and low resist thickness pattern is a resist fracture during the mold release operation. It seems due to interfacial adhesion between polymer and mold. However, in the present investigation, FEM simulation of NIL molding process was carried out to predict the defects of the polymer pattern and to optimize the process by FEA. The embossing operation in NIL process was investigated in detail by FEM. From the analytical results, it was found that the lateral flow of polymer resin and the applied pressure in the embossing operation induce the weld line and the drastic lateral strain at the edge of pattern. It was also shown that the low polymer-thickness result in the delamination of polymer from the substrate. It seems that the above phenomena cause the defects of the final polymer pattern. To reduce the defect, it is important to check the initial resin thickness.

  • PDF

Evaluation of canalis basilaris medianus using cone-beam computed tomography

  • Syed, Ali Z.;Zahedpasha, Samir;Rathore, Sonali A.;Mupparapu, Mel
    • Imaging Science in Dentistry
    • /
    • 제46권2호
    • /
    • pp.141-144
    • /
    • 2016
  • The aim of this report is to present two cases of canalis basilaris medianus as identified on cone-beam computed tomography (CBCT) in the base of the skull. The CBCT data sets were sent for radiographic consultation. In both cases, multi-planar views revealed an osseous defect in the base of the skull in the clivus region, the sagittal view showed a unilateral, well-defined, non-corticated, track-like low-attenuation osseous defect in the clivus. The appearance of the defect was highly reminiscent of a fracture of the clivus. The borders of osseous defect were smooth, and no other radiographic signs suggestive of osteolytic destructive processes were noted. Based on the overall radiographic examination, a radiographic impression of canalis basilaris medianus was made. Canalis basilaris medianus is a rare anatomical variant and is generally observed on the clivus. Due to its potential association with meningitis, it should be recognized and reported to avoid potential complications.

Sinus Tract Formation with Chronic Inflammatory Cystic Mass after Beta Tricalcium Phosphate Insertion

  • Kim, Hong Jin;Na, Woong Gyu;Jung, Sung Won;Koh, Sung Hoon;Lim, Hyoseob
    • 대한두개안면성형외과학회지
    • /
    • 제18권4호
    • /
    • pp.282-286
    • /
    • 2017
  • Beta tricalcium phosphate (${\beta}-TCP$) is one of allogenic bone substitute which is known to have interconnected pores that draws cell and nutrients for bone generation. It has been resulted in good outcomes for bone defect coverage or augmentation. However, several studies have also reported negative outcomes and associated complications including unexpected formation of cystic mass, continuous pain and secretion. We present the case of a 36-year-old man with a right cheek cystic mass who had a history of right zygomaticomaxillary (ZM) complex fracture and surgical correction with ${\beta}-TCP$ powder insertion to ZM bone defect. Excisional biopsy under local anesthesia revealed calcified mass in a sinus tract which was found to be connected to the ZM bone defect site in postoperative computed tomography image. Further excision under general anesthesia was performed to remove the sinus tract and fine granules which filled the original defect site. Pathologic report revealed bony spicules and calcification materials with chronic foreign body reaction. Postoperative complications and recurrence were not reported.

외상성 상악동 안구탈출의 치험례: 증례보고 (Traumatic Displacement of the Globe into the Maxillary Sinus: Case Report)

  • 임찬수;강동희
    • Archives of Plastic Surgery
    • /
    • 제34권4호
    • /
    • pp.524-527
    • /
    • 2007
  • Purpose: Globe displacement due to a blowout fracture is a rare clinical phenomenon. The authors present reduction of a globe displacement to the maxillary sinus due to trauma suffered in a fall and the reconstruction of a large defect left in the medial and inferior orbit. Methods: A 39-year-old male patient was unable to open his left eye after being struck on the periorbital area by a metal edge. Laceration was not noted in that area but we were unable to observe the intraorbital globe. A facial computed tomography (CT) scan showed that the globe was displaced through the maxillary sinus. A transconjunctival approach was used to access the infraorbital margin and the globe entrapped in the inferior margin of the orbit was successfully reduced. A large defect in the medial and inferior orbit was reconstructed using a graft from the iliac bone. Results: In 5 months after the operation, no atrophy of the globe was seen. Both sides retained a similar shape. A satisfactory functionality outcome in terms of improved extraocular muscle movement, and a satisfactory aesthetical outcome were achieved. Conclusion: The authors report the reduction of a globe displaced to the maxillary sinus following a fall and the reconstruction of the large defect left in the medial and inferior orbit.

실패한 족관절 인공관절 치환술 후 큰 골결손에서 내고정 없이 시행한 족관절 구제술: 증례 보고 (Ankle Salvage Procedure without Internal Fixation for Large Bone Defect after Failed Total Ankle Arthroplasty: A Case Report)

  • 박만준;은일수;정철용;고영철;류총일;김민우;황금민
    • 대한족부족관절학회지
    • /
    • 제18권2호
    • /
    • pp.76-79
    • /
    • 2014
  • In treatment of failure in ankle joint replacement therapy, talar avascular necrosis with massive bone defect, talus fracture with severe comminution and bone defect and ankle dislocation, treatment of large bone defects is considerably important for ankle joint stability and union, therefore, the choice of treatment for large bone defects is use of femoral head or iliac crest bone graft and rigid internal fixation. Because first generation total ankle arthroplasty performed for the first time using a cemented fixation technique requires a large amount of bone resection during re-surgery and there is some possibility of a larger bone defect after removal of implants, in cases where prosthesis for the defect is needed, performance of palliative femoral head or iliac crest bone graft and rigid internal fixation can be difficult. We report on a case of a 48-year-old woman who had experienced ankle pain for 25 years since undergoing total ankle arthroplasty. Because the patient had little ankle motion and rigid soft tissue despite a large bone defect caused by aseptic loosening, a good outcome was obtained only for the femoral cancellous bone graft using allo femoral head without internal fixation.

판형 복합재료의 충격 손상에 대한 비파괴시험적 고찰 (The Study of Nondestructive Test about Impact Damage of Plate Composite Materials)

  • 나성엽;김재훈;최용규;류백능
    • 한국추진공학회지
    • /
    • 제5권4호
    • /
    • pp.20-30
    • /
    • 2001
  • 본 연구는 적층각 및 적층구성이 다른 판형 복합재료의 충격 손상에 대하여 비파괴시험적 관점에서 고찰하였다. 연구를 위하여 직조 및 단일방향 프리프래그로 만든 두가지 형식의 복합재료에 낙하식 충격을 가한 후 비파괴검사를 수행하였다. 비파괴검사는 $ZnI_2$를 침투한 X-ray 검사 그리고 초음파 C-scan 검사를 수행하였고 결함의 종류에 따라 이들 검사에 대한 검출효과를 비교하였다. 그리고 두가지 형식의 복합재료 시험편에 대하여 충격 에너지별 결함의 발생정도를 비교하였다. 시험결과, 결함의 검출효과에 대하여서는 층간 분리 검출은 초음파 검사가 효과적이고 기지 크랙 및 섬유 파단은 침투제를 적용한 X-ray 검사가 효과적이었다. 그리고 적층각 및 적층구성에 따라 결함의 형상 및 발생정도에 상당한 차이가 있었으며, 충격 에너지가 증가할수록 기지 크랙, 층간 분리, 섬유 파단의 순으로 결함이 발생하였고 그 크기도 대체적으로 증가하는 경향을 보였다.

  • PDF

인공신경회로망을 이용한 원공결함을 갖는 유한 폭 판재의 음향방출 음원특성과 파괴거동에 관한 연구 (Acoustic Emission Source Characterization and Fracture Behavior of Finite-width Plate with a Circular Hole Defect using Artificial Neural Network)

  • 이장규;우창기
    • 한국공작기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.170-177
    • /
    • 2009
  • The objective of this study is to evaluate an acoustic emission (AE) source characterization and fracture behavior of the SM45C steel by using back-propagation neural network (BPN). In previous research Ref. [8] about k-nearest neighbor classifier (k-NNC) continuity, we used K-means clustering method as an unsupervised learning method for obtaining multi-variate AE main data sets, such as AE counts, energy, amplitude, risetime, duration and counts to peak. Similarly, we applied k-NNC and BPN as a supervised learning method for obtaining multi-variate AE working data sets. According to the error of convergence for determinant criterion Wilk's ${\lambda}$, heuristic criteria D&B(Rij) and Tou values are discussed. As a result, in k-NNC before fracture signal is detected or when fracture signal is detected, showed that produce some empty classes in BPN. And we confirmed that could save trouble in AE signal processing if suitable error of convergence or acceptable encoding error give to BPN.

파괴변형률모델에 기초한 결함이 존재하는 API X65 배관의 연성파괴 해석 (Ductile Failure Analysis of Defective API X65 Pipes Based on Stress-Modified Fracture Strain Criterion)

  • 오창균;백종현;김영표;김우식;김윤재
    • 대한기계학회논문집A
    • /
    • 제30권9호
    • /
    • pp.1086-1093
    • /
    • 2006
  • A local failure criterion for the API X65 steel is applied to predict ductile failure of full-scale API X65 pipes with simulated corrosion and gouge defects under internal pressure. The local failure criterion is the stress-modified fracture strain for the API X65 steel as a function of the stress triaxiality (defined by the ratio of the hydrostatic stress to the effective stress). Based on detailed FE analyses with the proposed local failure criteria, burst pressures of defective pipes are estimated and compared with experimental data. The predicted burst pressures are in good agreement with experimental data. Noting that an assessment equation against the gouge defect is not yet available, parametric study is performed, from which a simple equation is proposed to predict burst pressure fur API X65 pipes with gouge defects.

Surgical Correction of Pseudo-flail Chest Using Interfragmentary Wiring, Latissimus Dorsi Flap, and External Splinting in a Dog

  • Min, Byong-Su;Jeong, Soon-Wuk;Yoon, Hun-Young
    • 한국임상수의학회지
    • /
    • 제33권2호
    • /
    • pp.124-128
    • /
    • 2016
  • A 7-year-old intact female Maltese dog presented with a history of bite wounds. Physical examination revealed labored breathing, four puncture wounds with subcutaneous emphysema of the thorax, and paradoxical respiratory movement of the right thoracic wall. On radiography, a segmental fracture of the right 7th rib and a single fracture of the 8th rib were evident on the dorsal thorax. An inward displacement of the fractured segment and contusion of the right caudal lung lobe were identified with computed tomography. A diagnosis of pseudo-flail chest was made. Exploratory thoracotomy revealed a full-thickness muscular defect, a marked discoloration of the right caudal lung lobe, a segmental fracture of the right 7th rib, and a single fracture of the right 8th rib. Necrotic tissues were removed using surgical debridement. The fractured 7th and 8th ribs were corrected using a single interfragmentary wiring technique. The thoracic wall was reconstructed using the latissimus dorsi muscle flap. Additional thoracic stabilization using a thermoplastic splint was applied to correct paradoxical respiratory movement. The external splint was removed 4 weeks postoperatively. There was no evidence of respiratory abnormalities 18 months postoperatively.