Cracks evolution and multifractal of acoustic emission energy during coal loading

  • Kong, Xiangguo;Wang, Enyuan;He, Xueqiu;Liu, Xiaofei;Li, Dexing;Liu, Quanlin
    • Geomechanics and Engineering
    • /
    • 제14권2호
    • /
    • pp.107-113
    • /
    • 2018
  • Coal samples with different joints morphology were subjected to uniaxial compression experiments, cracks evolution was recorded by Nikon D5300 and acoustic emission (AE) energy signals were collected by AEwin Test for Express-8.0. During loading process, coal samples deformed elastically with no obvious cracks changes, then they expanded gradually along the trace of the original cracks, accompanied by the formation of secondary cracks, and eventually produced a large-scale fracture. It was more interesting that the failure mode of samples were all shear shape, whatever the original cracks morphology was. With cracks and damage evolution, AE energy radiated regularly. At the early loading stage, micro damage and small scale fracture events only induced a few AE events with less energy, while large scale fracture leaded to a number of AE events with more energy at the later stage. Based on the multifractal theory, the multifractal spectrum could explain AE energy signals frequency responses and the causes of AE events with load. Multifractal spectrum width (${\Delta}{\alpha}$), could reflect the differences between the large and small AE energy signals. And another parameter (${\Delta}f$) could reflect the relationship between the frequency of the least and greatest signals in the AE energy time series. This research is helpful for us to understand cracks evolution and AE energy signals causes.

Sacral Insufficiency Fractures : How to Classify?

  • Bakker, Gesa;Hattingen, Joerg;Stuetzer, Hartmut;Isenberg, Joerg
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권2호
    • /
    • pp.258-266
    • /
    • 2018
  • Objective : The diagnosis of insufficiency fractures of the sacrum in an elder population increases annually. Fractures show very different morphology. We aimed to classify sacral insufficiency fractures according to the position of cortical break and possible need for intervention. Methods : Between January 1, 2008 and December 31, 2014, all patients with a proven fracture of the sacrum following a low-energy or an even unnoticed trauma were prospectively registered : 117 females and 13 males. All patients had a computer tomography of the pelvic ring, two patients had a magnetic resonance imaging additionally : localization and involvement of the fracture lines into the sacroiliac joint, neural foramina or the spinal canal were identified. Results : Patients were aged between 46 and 98 years (mean, 79.8 years). Seventy-seven patients had an unilateral fracture of the sacral ala, 41 bilateral ala fractures and 12 patients showed a fracture of the sacral corpus : a total of 171 fractures were analyzed. The first group A included fractures of the sacral ala which were assessed to have no or less mechanical importance (n=53) : fractures with no cortical disruption ("bone bruise") (A1; n=2), cortical deformation of the anterior cortical bone (A2; n=4), and fracture of the anterolateral rim of ala (A3; n=47). Complete fractures of the sacral ala (B; n=106) : parallel to the sacroiliac joint (B1; n=63), into the sacroiliac joint (B2; n=19), and involvement of the sacral foramina respectively the spinal canal (B3; n=24). Central fractures involving the sacral corpus (C; n=12) : fracture limited to the corpus or finishing into one ala (C1; n=3), unidirectional including the neural foramina or the spinal canal or both (C2; n=2), and horizontal fractures of the corpus with bilateral sagittal completion (C3; n=8). Sixty-eight fractures proceeded into the sacroiliac joint, 34 fractures showed an injury of foramina or canal. Conclusion : The new classification allowes the differentiation of fractures of less mechanical importance and a risk assessment for possible polymethyl methacrylate leaks during sacroplasty in the direction of the neurological structures. In addition, identification of instable fractures in need for laminectomy and surgical stabilization is possible.

입내 분산형 Al2O3/Ag 나노복합체의 제조와 특성 (Preparation and Properties of the Intra-type Al2O3Ag Nanocomposites)

  • 천승호;한인섭;히데오 아와지
    • 한국세라믹학회지
    • /
    • 제44권4호
    • /
    • pp.208-213
    • /
    • 2007
  • Alumina/silver ($Al_2O_3/Ag$) nanocomposites with Ag content up to 9 vol% were prepared from nanopowder by soaking method using ${\gamma}-Al_2O_3$ of needle type and spark plasma sintering (SPS). The mechanical properties of specimens were investigated three-point flexural strength and toughness as a function of the Ag contents. The maximum flexural strength of the alumina/silver nanocomposite was 850 MPa for the 1 vol% composite, and also higher than monolith alumina as about 800 MPa at 3, 5, and 7 vol% Ag contents. Fracture toughness by single edged V-notch beam (SEVNB) was $4.05MPa{\cdot}m^{1/2}$ for the 3 vol% composite and maintained about $4.00MPa{\cdot}m^{1/2}$ at 5, and 7 vol% Ag content. Microstructure of fracture surface for each fracture specimens was observed. Due to the inhibition effect of alumina grain growth, the average grain size of nanocomposites depends on the content of Ag nano particles. The fracture morphology of nanocomposite with dislocation (sub-grain boundary) by silver nano-particles of second phases in the alumina matrix also showed transgranular fracture-mode compare with intergranular of monolith alumina. Thermal conductivity of specimens at room temperature was about 40 W/mK for the 1 vol% Ag content.

솔더 조인트 신뢰성 향상을 위한 무전해 니켈-도금의 표면형상 제어 (Study on Surface Morphology Control of Electroless Ni-P for Reliability Improvement of Solder Joints)

  • 이동준;최진원;조승현
    • 마이크로전자및패키징학회지
    • /
    • 제15권3호
    • /
    • pp.27-33
    • /
    • 2008
  • PDA, 핸드폰과 같은 포터블 제품의 사용이 급증함에 따른 전자 제품의 사용 환경의 변화는 제품의 솔더 조인트 신뢰성을 더욱 필요로 하게 되었다. 무전해 니켈/금 도금 표면 처리는 솔더링 특성이 우수하고, 표면처리 두께가 균일하며 패키징 공정에서 사용되는 광학설비에서 인식이 잘되기 때문에 미세피치 SMT 디바이스와 BGA 기판에 폭넓게 사용되고 있다. 그러나 무전해 니켈/금 도금 표면과 솔더 계면에서 발생되는 취성 파괴가 문제점으로 지적되고 있다. 솔더의 취성 파괴는 솔더링시 금속간 화합물과 무전해 니켈층 사이에 형성된 P-rich 영역의 갈바닉 니켈 부식에 의한 black pad 현상에 기인한다. 이론적으로 평탄한 무전해 Ni표면은 무전해 금도금 과정 중 도금액의 균일하게 순환되기 때문에 black pad 발생을 억제하는 장점을 가지고 있다. 그러나 이러한 장점에도 불구하고 무전해 Ni층의 표면형상을 어떻게 제어 할지에 대한 연구는 충분히 이루어 지지 않고 있다. 본 연구에서는 Cu 하지층의 표면 형상이 무전해 Ni층의 표면 형상에 미치는 영향에 대하여 분석하였다. 이를 위해 Cu 에칭액과 Cu에칭 처리 횟수를 변화시켜 Cu 하지층의 표면 형상을 다양하게 변화시켰다.

  • PDF

Are "Unstable" Burst Fractures Really Unstable?

  • Woo, Jun Hyuk;Lee, Hyun Woo;Choi, Hong June;Kwon, Young Min
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권6호
    • /
    • pp.944-949
    • /
    • 2021
  • Objective : The stability is an important factor to decide the treatment plan in thoracolumbar burst fracture patients. Patients with an unstable burst fracture generally need operative management. Decrease in vertebral body height, local kyphosis, involvement of posterior column, and/or canal compromise are considered important factors to determine the treatment plan. On the other hand, in thoracolumbar injury classification system (TLICS), surgery is recommended in patients with TLICS of more than 5 points. The purpose of this study was to apply the TLICS score in patients with thoracolumbar burst fractures and to distinguish the differences of treatment plan on burst fracture. Methods : All patients, diagnosed as a thoracolumbar burst fracture between January 2006 and February 2019 were included in this study. Unstable thoracolumbar burst fracture was defined as burst fracture with neurologic deficit, three-column injury, kyphosis over 30 degrees, decrease of anterior body height over 40 percent and canal comprise more than 50%. TLICS score was measured with morphology, neurological involvement and posterior ligamentous complex integrity. The existence of instability was compared with TLICS score. Results : Total 233 patients (131 men, 102 women) were included in this study. In Denis classification, 51 patients (21.9%) diagnosed as stable burst fracture while 182 patients (78.1%) had unstable burst fracture. According to TLICS, 72 patients (30.9%) scored less than 4, while 161 patients (69.1%) scored 4 or more. All the patients with stable burst fracture scored 2 in TLICS. Twenty-one patients (9.0) scored 2 in TLICS but diagnosed as unstable burst fracture. Thirteen patients had over 40% of vertebra body compression, four patients had more than 50% of canal compromise, three patients had both body compression over 40% and kyphosis over 30 degrees, one patients had both body compression and canal compromise. Fifteen patients presented kyphosis over 30 degrees, and three (20%) of them scored 2 in TLICS. Seventy-three patients presented vertebral body compression over 40% and 17 (23.3%) of them scored 2 in TLICS. Fifty-three patients presented spinal canal compromise more than 50%, and five (9.4%) of them scored 2 in TLICS. Conclusion : Although the instability of thoracolumbar burst fracture was regarded as a critical factor for operability, therapeutic strategies by TLICS do not exactly match with the concept of instability. According to the concept of TLICS, it should be reconsidered whether the unstable burst fracture truly unstable to do operation.

상완골 근위부 골절의 수술적 요법 (Operative treatment for Proximal Humeral Fracture)

  • 박진영;박희곤
    • 대한정형외과스포츠의학회지
    • /
    • 제2권2호
    • /
    • pp.168-175
    • /
    • 2003
  • 근위 상완골 골절은 골절의 형태에 따라 크게 관절편 또는 해부학적 경부, 대 결절, 소 결절, 상완골 간부 또는 외과적 경부의 4개의 골절편으로 나눌 수 있다. 현재 널리 사용되고 있는 Neer의 근위 상완골 골절의 분류는 골절선에 의해 골절편을 나누는 분류가 아니며, 1 cm이상전이나 45$^{\circ}$ 이상의 각형성 이 있는 경 우를 전 이 골절편으로 생각하였다. 골절에 대한 관혈적 정 복 및 내고정술의 일차적 적응증은 골다공증이 없는 젊은 환자에서 발생된 튼튼한 내고정물을 시행할 수 있는 삼분 골절로 만족할 만한 결과를 위해 술후 오랜 기간동안 시행할 재활치료에 잘견딜수 있는 활동력 이 좋은 환자여야 한다. 수술적 치료의 절대적 적응증은 개방성 골절 ,혈관이 나 신경 손상이 동반될 때 , 정복이 불가능한 골절 탈구등이다. 반대로 환자가 골다공증이 심하거나, 근위 상완 골절편의 분쇄정도가 심하며 , 튼튼한 내고정을 시행할 가능성 이 희박한 나이가 많은 경 우에는 관혈적 정복 및 내고정술보다 일차적 인공삽입물을 이 용한 관절성형 술을 시행한 후 조기 재활 치료를 시행하는 것을 고려할 수 있다. 상완골 근위부 골절의 수술적 요법에는 다양한 수술 기법과 이에 따른 여러 합병증이 발생할 수 있으며 지속적 이고 체계적 인 재활 치 료가 꼭 필요하다. 여러 수술 기 법 중 관혈적 정복 및 장력 대 강선 기법을 시행할 때 만족할 만한 결과를 얻 을 수 있다. 이 방법 은 수술적 기법이 어렵지 않고, 골에 대한 고정과 함께 회전근 개의 건부착 부위에 대한 봉합을 추가할 수 있으나 역시 여러 가지 합병증이 있으므로 골절의 양상이 나 환자의 상태 ,환자의 활동력 등을 고려하여 치료 방법을 결정하여야 할것으로 사료된다.EX>46N으로, 슬개건-티타늄 간섭나사군이평균 1067.4$\pm$145N에서평균 601.8$\pm$134N으로, 슬개건-생체흡수성간섭나사군이평균 987.1$\pm$168N에서588.7$\pm$124N으로각각40$\%$, 39$\%$, 50$\%$, 24$\%$, 44$\%$, 40$\%$가감소하였다. 결론: 수술후초기고정력은슬괵건을LA나사(R) 또는Semifix(R)로고정하는방법과슬개건을티타늄및생체흡수성간섭나사로고정하는방법등이우수하였으며, 슬괵건을생체흡수성간섭나사나Endobutton(R)으로 고정하는 방법 등은고정력이 상대적으로매우약함을 알수있었다. 최대인장력은단순인장검사로는이상의대퇴골측고정방법의고정력이초기부하를견뎌내는데충분하다고생각되었으나주기성부하실험후현저히감소되어충분한초기안정성을제공하지못함을알수있었다.를 나타내었다. 또한 3m깊이에서의 측방 선량분포에서 Spoiler의 거리변화(6, 10cm)는 심부선량의 변화에 영향을 주지 않는 것으로 확인할 수 있었다. 그리고 위의 실험측정치를 치료계획 시스템에 입력하여 선량분포를 확인한 결과 Spoiler를 사용하는 경우 OPEN에 비해 선량분포 영역을 표면으로 끌어 올릴 수 있으며 Bolus 보다 피부 보호효과는 어느 정도 유지가 되는 것을 보여주었다. 4.결론 이와 같이 Spoiler는 Bolus와 비교하여 6MV 광자선의 build up 영역을 표면으로 증가시키는 동시에 Skin Sparing(피부보호)효과를 유지할 수 있으며 두경부암의 치료에서 Spoiler의 사용이 가능한 조건으로는 조사면이

  • PDF

Ti-6Al-4V 합금의 미세조직에 따른 정적 및 동적 변형에 관한 연구 (The Effect of Microstructure on the Static and Dynamic Deformation Behavior of Ti-6Al-4V Alloy)

  • 이동근;이유환;이성학;허선무;이종수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2001년도 추계학술대회 논문집
    • /
    • pp.277-280
    • /
    • 2001
  • The effects of a -phase morphology on the static and dynamic deformation behavior of a Ti-6Al-4V alloy was investigated in this study. Static tension test, static and dynamic tension test and hot compression test were conducted on three microstructures of Ti-6Al-4V alloy, i.e., equiaxed, widmanstatten and bimodal microstructures. Fracture surfaces of all three microstructures represented ductile fracture appearance, though the formation of adiabatic shear bands was noticed at dynamic torsion test. The susceptibility of forming adiabatic shear bands was greatest in the equiaxed microsoucture and lowest in the bimodal microstructure, which was evidenced by hot compression test.

  • PDF

가열로 내부에서 발생하는 고탄소강 주편의 판파단 원인 분석 (Fracture Analysis of High Carbon Steel Slabs in a Furnace)

  • 김용주;장민지;;정영진;김형섭
    • 소성∙가공
    • /
    • 제29권3호
    • /
    • pp.151-156
    • /
    • 2020
  • In general, the cause of slab cracking during heat treatment has been analyzed with focus on processing conditions. However, in the present work, the cause of cracking is analyzed based on the microstructural evolution during heat treatment. The microstructural analysis indicates that the structure of the slab consists of three main regions as the top, quarter, and center parts. The tensile properties are investigated in each region of the slab in the temperature range from 25 to 350 ℃. Results demonstrate that the cracking is mainly attributed to the thermal stress and specific morphology of the microstructure. It is proposed that the cracking during the heat treatment is related to the presence of inclusion at the ferrite phase which is located at the boundary of pearlite grains.

EFFECT OF POST-WELD HEAT TREATMENT OF MARINE STRUCTURE STEEL DURING CATHODIC PROTECTION

  • Kim, Seong-Jong;Masazumi Okido;Kim, Jin-Gyeong;Moon, Kyung-Man
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.273-275
    • /
    • 2002
  • The effect of post-weld heat treatment (PWHT) of marine structures steel was investigated at electrochemical viewpoint. In addition, slow strain rate test (SSRT) was carried out to investigate both electrochemical and mechanical properties by PWHT effect during impressed current cathodic protection. The optimum cathodic protection potential by SSRT was -770 mV(SCE). At the applied cathodic protection potential of -770 mV -850 mV(SCE), the fracture morphology was dimple pattern with ductile fracture, while it was transgranular pattern (Q.C: quasi cleavage) under -875 mV(SCE).

  • PDF

혼합강화 복합재료의 인장 및 내마모 특성 (The Tensile Properties and Wear Behavior of Mixing-reinforced Composites by Squeeze Casting Process)

  • 김용현;이광학
    • 한국재료학회지
    • /
    • 제9권4호
    • /
    • pp.392-397
    • /
    • 1999
  • The tensile strength and water resistance of ADC12 alloy matrix composites reinforced with saffil/ceraklwool and saffil/Si particle prepared by squeeze casting have been investigated in room temperature and $250^{\circ}C$. Adhesive and scuffing wear phenomena was studied when load was changed to 10~40N and wear velocity was 2.0m/s at room temperature and $250^{\circ}C$. Generally, the morphology of tensile fractured surface revealed dimple pattern which implies ductile fracture of the composites. However, cleavage fracture was also observed in case of ADC12 alloy based saffil/Si particle composite. The maximum tensile strength of 320MPa was obtained in ADC12 alloy based composites reinforced by saffil/cerakwool(5:5) preformed fibers. In the results of dry wear test, it was observed that scuffing was occurred at 40N in room temperature and 30N for $250^{\circ}C$.

  • PDF