• Title/Summary/Keyword: Fracture Fixation

Search Result 804, Processing Time 0.027 seconds

The Size of Calcaneus in Koreans (한국인의 종골 크기)

  • Kim, Jin-Su;Cho, Hun-Ki;Hwang, Sae-Min;Lee, Keun-Woo;Young, Ki-Won;Lee, Kyung-Tai
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.143-149
    • /
    • 2013
  • Purpose: Open reduction and internal fixation of calcaneal fracture using plate has been used. While numerous plates have been manufactured, most of the conventional plates are designed for westerners, realistically the size is larger for Korean. The domestic products, on the other hand, often have the undesirable screw holes and path. Therefore, we measured the radiologic parameter of Korean calcaneus for providing the plate and screw hole placements. Materials and Methods: We measured the outer lines and angles with over the 20 years old 291 females and 322 males. A: Length of inferior plane of calcaneus, B: Length of anterior plane of calcaneus, C: Length from line A to sinus tarsi, D: Length from line A to posterior point of posterior facet, E: Length from line A to calcaneal tuberosity, F: Length of posterior facet, G: Length from anterior point of line A to C, H: Length from line C to line D, a: Angle between A and B, b: Gissane angle, c: Bohler angle, d: Calcaneal pitch angle using Marosis m-view$^{(R)}$. Results: Mean A, B, C, D, E, F, G, H were 63.6, 26.4, 23.2, 43.7, 40.5, 26.9, 12.8, 18.1 mm. Mean a, b, c, d angle were 105.8, 122.4, 32.4, $20.5^{\circ}$. Male's calcaneus is significantly bigger than female's (p<0.001). Conclusion: AP calcaneus length 63.6 mm, maximal height 43.7 mm is considered to be helpful in making the Korean calcaneal plate.

The Importance of the Trauma Surgeon: A Reflection on the Management of Hemodynamically Unstable Pelvic Trauma Patients (혈역학적으로 불안정한 골반외상 환자의 치료를 통해 본 외상전문의의 필요성)

  • Shin, Sung;Kyung, Kyu Hyuk;Kim, Ji Wan;Kim, Jung Jae;Hong, Suk-Kyung
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.254-259
    • /
    • 2009
  • Purpose: Pelvic trauma is a serious skeletal injury with high mortality. Especially in cases of severe injury trauma, treatment outcomes depend on early diagnosis and intervention. We expect trauma surgeon to play an important role in the management of severe multiple trauma patients. Methods: A retrospective study was performed on pelvic trauma patients with hemodynamic instability between March 2005 and September 2009. We divided the time period into period I (March 2005~Feburary 2009) and period II (March 2009~September 2009). The trauma surgeon and team started to work from period II. Data were collected regarding demographic characteristics, mechanism of injury, type of pelvic fracture, ISS(injury severity score), treatment modality, transfusion requirement, time to definitive treatment, and mortality. Results: During period I, among 7 hemodynamically unstable patients, 4(57.1%) patients died. However during Period II, only one of 6(16.6%) patients died. The demographic data and injury scores showed no differences between the two time periods, but the time to definitive treatment was very short with trauma team intervention(14.4 hrs vs. 3.9 hrs). Also, the amount of transfusion was less(41.1 U vs. 13.9 U). With arterial embolization, early pelvic external fixation led to less transfusion and made patients more stable. Conclusion: This study demonstrated the importance of the trauma surgeon and the trauma team in cases of hemodynamically unstable pelvic trauma. Even with the same facility and resources, an active trauma team approach can increase the survival of severely injured multiple trauma patients.

Short Scarf Osteotomy for Moderate Hallux Valgus (중등도 무지외반증에서 시행한 단축 스카프 절골술)

  • Kwon, Soon-Yong;Gil, Ho-Jin;Chung, Jin-Wha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.4
    • /
    • pp.235-240
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the radiographic and clinical results of short scarf osteotomy that has minimized longitudinal cut for moderate hallux valgus. Materials and Methods: Total 12 patients (12 feet) were reviewed by medical records and radiographs. All patients were female and the mean age at the time of operation was 41.5 years. The mean followup time was 21.2 months. We modified original scarf osteotomy by shortening the longitudinal cut to 15~20 mm in length. Additionally, Akin osteotomy of the first proximal phalanx was done in 7 feet and Weil osteotomy of the second metatarsal was done in 4 feet. First-second intermetatarsal and hallux valgus angles were analyzed radiographically before and after the operation. And the clinical result was assessed by AOFAS (American Orthopaedic Foot and Ankle Society) hallux score. Results: First-second intermetatarsal and hallux valgus angles were reduced from the mean preoperative values of $14.6^{\circ}$ and $32.8^{\circ}$ to $6.5^{\circ}$ and $11.2^{\circ}$, respectively. The mean AOFAS hallux score was increased from 52.4 points preoperatively to 88.2 points at followup. Three complications were found: metatarsal fracture during the operation, painful scar around second metatarsal head after Weil osteotomy and postoperative neuralgia. There was no transfer metatarsalgia or recurrence of hallux valgus during followup. Conclusion: Short scarf osteotomy would be an effective surgical procedure for moderate hallux valgus with the benefits of minimized soft tissue dissection and stable fixation.

Comparison of resorbable plates and titanium plates for fixation stability of combined mandibular symphysis and angle fractures

  • Lim, Ho-Yong;Jung, Chang-Hwa;Kim, Seong-Yong;Cho, Jin-Yong;Ryu, Jae-Young;Kim, Hyeon-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.6
    • /
    • pp.285-290
    • /
    • 2014
  • Objectives: We compared resorbable plates with titanium plates for treatment of combined mandibular angle and symphyseal fractures. Materials and Methods: Patients with mandibular angle and symphysis fractures were divided into two groups. The control (T) group received titanium plates while the experimental (R) group received resorbable plates. All procedures were carried out under general anesthesia using standard surgical techniques. We compared the frequency of wound dehiscence, development of infection, malocclusion, malunion, screw breakage, and any other technical difficulties between the two groups. Results: Thirteen patients were included in the R group, where 39 resorbable plates were applied. The T group consisted of 16 patients who received 48 titanium plates. The mean age in the R and T groups was 28.29 and 24.23 years, respectively. Primary healing of the fractured mandible was obtained in all patients in both groups. Postoperative complications were minor and transient. Moreover, there were no significant differences in the rates of various complications between the two groups. Breakage of 3 screws during the perioperative period was seen in the R group, while no screws or plates were broken in the T group. Conclusion: Resorbable plates can be used to stabilize combined mandibular angle and symphysis fractures.

Use of resorbable mesh and fibrin glue for restoration in comminuted fracture of anterior maxillary wall

  • Yang, Jae-Hyuk;Chang, Suk Choo;Shin, Jin Yong;Roh, Si-Gyun;Lee, Nae-Ho
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.175-180
    • /
    • 2018
  • Background: The facial bone has a complex structure compared to other bones, and various types of fractures can occur due to its characteristics. Among them, in comminuted fractures of anterior maxillary wall, multiple depressed and impacted bony segments cannot be reduced easily when performing internal fixation using plates and screws or wires, and inadequate restoration leads to a range of complications. This paper introduces an alternative technique using a resorbable mesh with fibrin glue to restore comminuted fractures of anterior maxillary wall. Methods: Thirteen patients were diagnosed with comminuted fractures of anterior maxillary wall between March 2017 and February 2018 in the authors' hospital. All patients with comminuted fractures of anterior maxillary wall underwent restoration using resorbable mesh with fibrin glue. The patients' demographics, causes of facial trauma, mean operation time, length of hospital stay, follow-up period, and complications were recorded. Results: No major complications and only one hypoesthesia of the skin area was noted. Three months after surgery, the hypoesthesia recovered completely. After surgery (mean, 3.9 months; range, 2-12 months), computed tomography showed that the bone fragments in all patients were fixed successfully in their anatomical places. Conclusion: In comminuted fractures of anterior maxillary wall, the use of a resorbable mesh with fibrin glue can be an advantageous and effective method for a successful restoration without complications.

Sciatic Nerve Injury Following a Delayed Surgical Procedure for the Hamstring Muscle Avulsion from the Ischial Tuberosity - A Case Report - (슬근 좌골 결절 견열 손상의 지연 수술후 발생한 좌골신경 손상 - 증례 보고 -)

  • Kim Hui Taek;Yoo Chong Il;Yun Pyung Ju;Lee Jong Seo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.75-78
    • /
    • 2002
  • Avulsion of the hamstring tendon from the ischial tuberosity is common in many sports, especially with younger athletes. The injury results from a sudden forceful flexion of the hip joint when the knee is extended and the hamstring muscles powerfully contracted. Early diagnosis and surgical repair with reattachment of avulsed muscles to the ischial tuberosity restore function and correct deformity. But, a delay in the diagnosis and treatment leads to a poor result functionally and clinically. Complication, such as heterotopic ossification and failure of the fixation, etc., were reported following a surgical procedure for this injury. However, sciatic nerve injury has not been reported in the literature. We report our experience of a sciatic nerve palsy after surgery that was performed three months after that the initial injury.

  • PDF

Hydrothermal Synthesis of $TiO_2$ Nanowire Array for Osteoblast Adhesion

  • Yun, Young-Sik;Kang, Eun-Hye;Hong, Min-Eui;Yun, In-Sik;Kim, Yong-Oock;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.275-275
    • /
    • 2013
  • Osteoblast is one of cells related with osseointegration and many research have conducted the adhesion of osteoblast onto the surface of implant. In the osseointegration, biocompatibility of the implant and cell adhesion to the surface are important factors. The researches related to cell adhesion have a direction from micro-scaled surface roughness to nano-scaled surface roughness with advancing nanotechnology. A cell reacts and sense to stimuli from extracellular matrix (ECM) and topography of the ECM [1]. Thus, for better osseointegration, we should provide an environment similar to ECM. In this study, we synthesize TiO2 nanowires using hydrothermal reaction because TiO2 provides inertness to titanium on its surface and enables it used as an implant material for the orthopedic treatment such as fixation of the bone fracture [2]. Ti substrate is immersed into NaOH aqueous solution. The solution are heated at $140{\sim}200^{\circ}C$ for various time (10~720 minutes). After heat treatment, we take out the sample and immerse it into HCl aqueous solution for 1 hour. The acid treated sample is heated again at $500^{\circ}C$ for 3 hours [3]. Then, we culture osteoblast on the TiO2 nanowires. For investigating cell adhesion onto nanostructured surface, we conduct several tests such as MTT assay, ALP (Alkaline phosphatase) activity assay, measuring calcium expression, and so on. These preliminary results of the cell culture on the nanowires are foundation for investigating cell-material interaction especially with nanostructure interaction.

  • PDF

A working paradigm for managing mandibular fractures under regional anesthesia

  • Chellappa, Natarajan;Meshram, Vikas;Kende, Prajwalit;Landge, Jayant;Aggarwal, Neha;Tiwari, Manish
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.6
    • /
    • pp.275-281
    • /
    • 2018
  • Objectives: Isolated mandibular fractures contribute to approximately 45% of maxillofacial traumas. Improper management of mandibular fractures can cause myriad potential complications and can lead to serious functional and aesthetic sequelae. The objective of the study is to design a stepwise approach for managing isolated mandibular fractures using open reduction and internal fixation (ORIF) with regional anesthesia on outpatient basis. Materials and Methods: Patients with isolated mandibular fractures presenting to the department of maxillofacial surgery were selected for ORIF under regional anesthesia based on occlusion, age, socioeconomic status, general condition, habits, and allied medical ailments. Standard preoperative, intraoperative, and postoperative protocols were followed. All patients were followed up for a minimum of 4 weeks up to a maximum of 1 year. Results: Of 23 patients who received regional anesthesia, all but one had good postoperative functional occlusion. One patient was hypersensitive and had difficulty tolerating the procedure. Two patients developed an extraoral draining sinus, one of whom was managed with local curettage, while the other required hardware removal. One patient, who was a chronic alcoholic, returned 1 week after treatment with deranged fracture segments after he fell while intoxicated. Conclusion: With proper case selection following a stepwise protocol, the majority of mandibular fractures requiring ORIF can be managed with regional anesthesia and yield minimal to no complications.

Strut Support with Tricortical Iliac Allografts in Unstable Proximal Humerus Fractures: Surgical Indication and New Definition of Poor Medial Column Support

  • Lee, Seung-Jin;Hyun, Yoon-Suk;Baek, Seung-Ha
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.29-36
    • /
    • 2019
  • Background: The execution of fibular allograft augmentation in unstable proximal humerus fractures (PHFs) was technically demanding. In this study, the authors evaluated the clinical and radiographic outcomes after tricortical iliac allograft (TIA) augmentation in PHFs. Methods: We retrospectively assessed 38 PHF patients treated with locking-plate fixation and TIA augmentation. Insertion of a TIA was indicated when an unstable PHF showed a large cavitary defect and poor medial column support after open reduction, regardless of the presence of medial cortical comminution in preoperative images. Radiographic imaging parameters (humeral head height, HHH; humeral neck-shaft angle, HNSA; head mediolateral offset, HMLO; and status of the union), Constant score, and range of motion were evaluated. Patients were grouped according to whether the medial column support after open reduction was poor or not (groups A and B, respectively); clinical outcomes were compared for all parameters. Results: All fractures healed radiologically (average duration to complete union, 5.8 months). At final evaluation, the average Constant score was 73 points and the mean active forward flexion was $148^{\circ}$. Based on the Paavolainen assessment method, 33 patients had good results and 5 patients showed fair results. The mean loss of reduction was 1.32 mm in HHH and 5.02% in HMLO. None of the parameters evaluated showed a statistically significant difference between the two groups (poor and not poor medial column support). Conclusions: In unstable PHFs, TIA augmentation can provide good clinical and radiological results when there are poor medial column support and a large cavitary defect after open reduction.

Dental alloplastic bone substitutes currently available in Korea

  • Ku, Jeong-Kui;Hong, Inseok;Lee, Bu-Kyu;Yun, Pil-Young;Lee, Jeong Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.2
    • /
    • pp.51-67
    • /
    • 2019
  • As dental implant surgery and bone grafts were widely operated in Korean dentist, many bone substitutes are commercially available, currently. For commercially used in Korea, all bone substitutes are firstly evaluated by the Ministry of Health and Welfare (MOHW) for safety and efficacy of the product. After being priced, classified, and registration by the Health Insurance Review and Assessment Service (HIRA), the post-application management is obligatory for the manufacturer (or representative importer) to receive a certificate of Good Manufacturing Practice by Ministry of Food and Drug Safety. Currently, bone substitutes are broadly classified into C group (bone union and fracture fixation), T group (human tissue), L group (general and dental material) and non-insurance material group in MOHW notification No. 2018-248. Among them, bone substitutes classified as dental materials (L7) are divided as xenograft and alloplastic bone graft. The purpose of this paper is to analyze alloplastic bone substitutes of 37 products in MOHW notification No. 2018-248 and to evaluate the reference level based on the ISI Web of Knowledge, PubMed, EMBASE (1980-2019), Cochrane Database, and Google Scholar using the criteria of registered or trademarked product name.