• Title/Summary/Keyword: Fracture%2C Bone

Search Result 63, Processing Time 0.023 seconds

Geochemistry of Heavy Metals and Rare Earth Elements in Core Sediments from the Korea Deep-Sea Environmental Study (KODES)-96 Area, Northeast Equatorial Pacific (한국심해환경연구(KODES) 지역 주상 퇴적물중 금속 및 희토류원소의 지구화학적 특성)

  • Jung, Hoi-Soo;Park, Sung-Hyun;Kim, Dong-Seon;Choi, Man-Sik;Lee, Kyeong-Young
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.2 no.2
    • /
    • pp.125-137
    • /
    • 1997
  • To study the vertical variation of heavy metal and Rare Earth Element (REE) contents in deep-sea sediments, eighteen cores were sampled from the Korea Deep-sea Environmental Study (KODES)-96 area in the C-C zone (Clarion-Clipperton fracture zone), northeast equatorial Pacific. Sediment columns can be divided into three units based on sediment colors and geochemical characters; uppermost Unit I with brown color, middle Unit II with pale brown color and smaller Ni/Cu ratio than the ratio in Unit I, and lowermost Unit III with dark (brown) colors and higher contents of Mn, Ni, Cu, and REEs than those in Unit I and II. Unit II can be divided more into two layers of upper Unit IIa and lower Unit IIb. Unit IIb is characterized by high contents of Cu, 3+REEs (REEs except Ce), smectite, and severely deteriorated fossil tests. Unit III can also be divided into two units; upper Unit IIIa with dark brown color, and lower Unit IIIb with black color and enriched Mn and Fe. The KODES area was located near from the East Pacific Rise (EPR) When Unit III Sediments were deposited, considering the hiatus between Unit II and III (Quaternary-Tertiary boundary) and the spreading rate (10 cm/yr) and direction (north southern west) of the Pacific plate from the EPR. High contents of Mn and Fe in Unit IIIb may be related with hydrothermal influence from the EPR. Meanwhile, Unit IIb (about 2~3 Ma) and Unit III (11~30 Ma) layers were probably formed near (or under) the equatorial high productivity zone, and accordingly received a lot of organic materials. As a result, Cu and 3+REEs, closely associated with organic materials, are enriched in smectite and/or Ca-P composites (fish bone debrise, biogenic apatite) after decomposition and reprecipitation on the sea floor. Higher contents of Cu and 3+REEs in Unit IIb and III are suggested to be the result of abundant supply of organic substances in the equatorial high productivity zone.

  • PDF

Treatment of Distal Tibial Spiral Fractures Combined with Posterior Malleolar Fractures (후과 골절이 동반된 경골 원위부 나선상 골절의 치료)

  • Kim, Young Sung;Lee, Ho Min;Kim, Jong Pil;Chung, Phil Hyun;Park, Soon Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.4
    • /
    • pp.317-325
    • /
    • 2021
  • Purpose: This study compared the functional and radiologic outcomes of intramedullary nailing (IMN) and minimally invasive plate osteosynthesis (MIPO) for tibia fractures in distal tibial spiral fractures combined with posterior malleolar fractures, as well as the functional and radiologic outcomes with and without fixation for posterior malleolar fractures. Materials and Methods: From January 2010 to December 2018 the radiological and clinical outcomes of 30 skeletally mature patients with tibial spiral fractures (AO Foundation/Orthopaedic Trauma Association classification 42-A1, B1, C1) combined with posterior malleolar fractures were analyzed. Sixteen patients were treated with IMN, and 14 patients were treated with MIPO. Depending on the surgical methods, the radiologic and clinical outcomes were compared by evaluating the bone union time, postoperative alignment, postoperative displacement of the posterior malleolar fragment, and American Orthopaedic Foot and Ankle Society (AOFAS) score. Moreover, the functional and clinical outcomes with and without fixation for posterior malleolar fractures were compared. Results: The mean bone union time was 21.8 weeks in the IMN group and 23.1 weeks in the MIPO group (p=0.500). At the final follow up, the mean alignment was coronal angulation of 1.8°, sagittal angulation of 1.6° in the IMN group and coronal angulation of 1.2° and sagittal angulation of 1.7° in the MIPO group (conoral angulation: p=0.131, sagittal angulation: p=0.850). The postoperative and final radiologic evaluation showed no displacement of the posterior malleolar fragment and excellent joint congruity in all cases. At the final follow-up, the mean AOFAS score was 88.0 on average in the IMN group and 87.6 on average in the MIPO group (p=0.905). The ankle range of motion and AOFAS score were similar in the fixation group and no fixation group for posterior malleolar fractures. Conclusion: Both IMN and MIPO for tibial spiral fractures combined with posterior malleolar fractures result in satisfactory radiological and clinical outcomes.

Double Tension Band Osteosynthesis in Intra-articular Fractures of the Distal Humerus (AO type C) in Elderly Osteoporotic Patients (고령 환자의 상완골 원위부 AO-C형 골절에서 이중 강선 장력대 고정술)

  • Cheon, Sang Jin;Lee, Dong Ho;Goh, Tae Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.33-39
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the clinical result of intra-articular fractures of the distal humerus (AO type C) in elderly osteoporotic patients treated with double tension band osteosynthesis. Materials and Methods: From January 2006 to December 2010, 10 elderly osteoporotic patients(1 male, 9 females) with intra-articular fractures of the distal humerus (AO type C) were treated with double tension band osteosynthesis. The mean age of patients at the time of surgery was 74.6(66~84) years and the mean follow-up period was 39.2(20~74) months. The fracture union and complications were assessed and the functional result was evaluated by the rating system of Jupiter et al. and the Mayo elbow performance index. Results: Bone union was achieved in all patients with no secondary displacement. The mean time for union was 16.6(13~22) weeks. The average postoperative arc of elbow flexion was 119(100~140) degrees with a mean flexion contracture of 8.5(0~15) degrees. The recovery in two patients was rated as excellent, in 7 as good, and in 1 as fair in terms of the Mayo elbow performance index with average value of 82(70~90) points. Seven patients were rated as excellent, 1 as good, and 2 as fair in terms of the rating system of Jupiter et al. Changing tension band wiring was performed in one patient as skin irritation was noticed due to tension band knots. Heterotopic ossification developed in one patient but had no symptom. Conclusion: Double tension band osteosynthesis in intra-articular fractures of distal humerus (AO type C) in elderly osteoporotic patients can provide sufficient and secure stability to allow early rehabilitation.