• Title/Summary/Keyword: Fourier spectra

Search Result 333, Processing Time 0.028 seconds

Spectra of nonlinear shallow water waves (비선형 천해파의 스펙트라)

  • Zahibo, Narcisse;Didenkulova, Ira;Pelinovsky, Efim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.4
    • /
    • pp.355-360
    • /
    • 2007
  • The process of the nonlinear shallow water wave transformation in a basin of a constant depth is studied. Characteristics of the first breaking of the wave are analyzed in details. The Fourier spectrum and steepness of the nonlinear wave are calculated. It is shown that the spectral amplitudes can be expressed using the wave front steepness, which allows the practical estimations.

Decomposition of Speech Signal into AM-FM Components Using Varialle Bandwidth Filter (가변 대역폭 필터를 이용한 음성신호의 AM-FM 성분 분리에 관한 연구)

  • Song, Min;Lee, He-Young
    • Speech Sciences
    • /
    • v.8 no.4
    • /
    • pp.45-58
    • /
    • 2001
  • Modulated components of a speech signal are frequently used for speech coding, speech recognition, and speech synthesis. Time-frequency representation (TFR) reveals some information about instantaneous frequency, instantaneous bandwidth and boundary of each component of the considering speech signal. In many cases, the extraction of AM-FM components corresponding to instantaneous frequencies is difficult since the Fourier spectra of the components with time-varying instantaneous frequency are overlapped each other in Fourier frequency domain. In this paper, an efficient method decomposing speech signal into AM-FM components is proposed. A variable bandwidth filter is developed for the decomposition of speech signals with time-varying instantaneous frequencies. The variable bandwidth filter can extract AM-FM components of a speech signal whose TFRs are not overlapped in timefrequency domain. Also, amplitude and instantaneous frequency of the decomposed components are estimated by using Hilbert transform.

  • PDF

Removal of Uranium from Aqueous Solution by Alginate Beads

  • Yu, Jing;Wang, Jianlong;Jiang, Yizhou
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.534-540
    • /
    • 2017
  • The adsorption of uranium (VI) by calcium alginate beads was examined by batch experiments. The effects of environmental conditions on U (VI) adsorption were studied, including contact time, pH, initial concentration of U (VI), and temperature. The alginate beads were characterized by using scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. Fourier transform infrared spectra indicated that hydroxyl and alkoxy groups are present at the surface of the beads. The experimental results showed that the adsorption of U (VI) by alginate beads was strongly dependent on pH, the adsorption increased at pH 3~7, then decreased at pH 7~9. The adsorption reached equilibrium within 2 minutes. The adsorption kinetics of U (VI) onto alginate beads can be described by a pseudo first-order kinetic model. The adsorption isotherm can be described by the Redlich-Peterson model, and the maximum adsorption capacity was 237.15 mg/g. The sorption process is spontaneous and has an exothermic reaction.

Fourier Transform Infrared Spectroscopic Analysis of the Silylated Resist on Silicon Wafers in Semiconductor Lithographic Process (반도체 사진공정에서 실리콘 웨이퍼 위의 Silylated Resist의 Fourier 변환 적외선 분광분석)

  • Kang, Sung Chul;Kim, Su Jong;Son, Min Young;Park, Chun Geun
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.455-464
    • /
    • 1992
  • Using FT-IR, we determined the depth of silylated layers produced from various gas-phase-silylation conditions was proposed by using Fourier Transform Infrared (FT-IR) spectroscopic analysis. The depth of silylated layer was determined from absorbance measurments of the significant peaks (Si-O-ph, Si-C, Si-H) of FT-IR spectra with background spectrum subtraction method. And the results were compared with thickness measurments of SEM. The results were well agree with SEM. It found to be well suited for determining silylation process window.

  • PDF

Distortion Correction Method Using Spectral Characteristics of Integral Images (집적영상의 스펙트럼 특성을 이용한 왜곡 교정 방법)

  • Jin, Zhengju;Lee, Byung-Ju;Kang, Hyun-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.10
    • /
    • pp.1-8
    • /
    • 2013
  • In this paper, we propose a new method to correct the perspective distortion that occurs in the process of acquiring the integral images. In the proposed method, the distortion correction is based on the spectral characteristics of integral images. As element images of an integral image are repeated nearly periodically, its Fourier spectrum is given as an impulse train. On the contrary, the impulse train do not appear in the spectra of distorted images. In the proposed method, therefore, the perspective distortion parameters are detected by using the characteristics of the spectrum obtained through the Fourier transform, and then the distorted images are corrected by using the parameters. Through experiments, we verify that the proposed method effectively works for the perspective distortion correction.

Aqueous Glucose Solution Measurement by Three Types NIR Spectrometer (세 가지 방식의 근적외선 분광분석기를 이용한 글루코오스 수용액의 측정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.6
    • /
    • pp.461-468
    • /
    • 2003
  • A method is described for measuring clinically relevant levels of glucose in a pH 7.4 phosphate buffer by nearinfrared (NIR) absorption spectroscopy. Three types of NIR spectrometer, dispersive type, photo-diode array (PDA) type, and fourier transform (FT) type spectrometer were used and the performance was compared. Spectra were collected with a cuvette cell or quartz liquid fiber of 1 mm or 2 mm optical pathlength as transmittance method. Glucose absorption band appeared at second overtone, first overtone, and combination region for all systems. By use of the multivariate technigue of partial least squares (PLS) regression, glucose concentrations can be determined with a 16, 44, and 9.1 mg/d l standard error of prediction for dispersive type, photo-diode array type, and fourier transform type system, respectively. Sensitivity of spectrometer was evaluated by absorbance for the difference of 10 mg/d l glucose. Three absorption bands, second overtone, first overtone, and combination region were suited to three types systems, dispersive type, photo-diode array type, and fourier transform type systems, respectively. This investigation showed that three types NIR spectrometer were proper method for identification and quantitative analysis of glucose and possible for noninvasive blood glucose monitoring.

Accurate Heartbeat Frequency Extraction Method using UWB Impulse Radar

  • Cho, Hui-Sup;Park, Young-Jin
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.4
    • /
    • pp.246-252
    • /
    • 2017
  • Non-invasive and non-restrictive methods for measuring the physiological functions of the human body are useful for health care, security, and surveillance. In this paper, a new method that extracts human heartbeat information by utilizing ultra-wideband (UWB) impulse radar is proposed. The amplitude spectra of received radar pulses reflected from the human body are accumulated at specific time intervals, and chirp z-transform (CZT) is used to extract the heartbeat frequency from the amplitude spectra. The heartbeat frequency can be extracted with high-frequency resolution in the frequency band of the heartbeat of interest using CZT. Experimental results to verify the performance of the proposed method show that a highly accurate extraction of the heartbeat frequency is possible using this method.

Location and Frequency Domain Detection of Corona Discharge Point in Oil Using AE Sensor (AE센서를 이용한 유중 코로나방전점 위치 및 주파수 영역 검출)

  • 이상우;김성훈;김인식;김기채;박원주;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.127-131
    • /
    • 1999
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane electrode was analyzed to determine the proper ultrasonic sensor. We also examined the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] AC high-voltage in oil. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were found to be 130[kHz] by the fast fourier transform. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages. Also the detection of corona discharge point location by AE signals was found to be possible by using two sensors.

  • PDF

Effect of Preparation on Structure and Magnetic Properties of ZnFe2O4

  • Niyaifar, Mohammad
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.101-105
    • /
    • 2014
  • In this work, Zinc ferrite nanoparticles have been prepared by various methods, conventional (ZC), mechanochemical processing (ZM) and Sol-Gel (ZS) method, to compare their structural and magnetic properties. The cation distribution obtained from XRD shows the degrees of inversions are 4%, 14.8%, and 16.4% from the normal $ZnFe_2O_4$ structure. Fourier transform infrared spectroscopy (FT-IR) confirms changes in cation distribution of $ZnFe_2O_4$ fabricated by sol-gel and mechanochemical processing. The $^{57}Fe$ M$\ddot{o}$ssbauer spectra of the samples were recorded at room temperature. The spectra exhibit a line broadening. The magnetic properties of the samples were studied by vibration sample magnetometer (VSM) at room temperature and the results show that the sample ZM has ferrimagnetic behaviour.

Application of Clustering Methods for Interpretation of Petroleum Spectra from Negative-Mode ESI FT-ICR MS

  • Yeo, In-Joon;Lee, Jae-Won;Kim, Sung-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3151-3155
    • /
    • 2010
  • This study was performed to develop analytical methods to better understand the properties and reactivity of petroleum, which is a highly complex organic mixture, using high-resolution mass spectrometry and statistical analysis. Ten crude oil samples were analyzed using negative-mode electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FT-ICR MS). Clustering methods, including principle component analysis (PCA), hierarchical clustering analysis (HCA), and k-means clustering, were used to comparatively interpret the spectra. All the methods were consistent and showed that oxygen and sulfur-containing heteroatom species played important roles in clustering samples or peaks. The oxygen-containing samples had higher acidity than the other samples, and the clustering results were linked to properties of the crude oils. This study demonstrated that clustering methods provide a simple and effective way to interpret complex petroleomic data.