• Title/Summary/Keyword: Four canals

Search Result 101, Processing Time 0.023 seconds

Working length change by instrumentation in curved canals

  • Jo, Jeong-Im;Park, Jeong-Won;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.589-590
    • /
    • 2003
  • Mesiobuccal or distobuccal canals of maxillary molars and mesiobuccal or mesiolingual canals of mandibular malars were selected. Forty specimens were divided into four groups according to the instruments used : stainless steel K-files($MANI^{\circledR}$, Matsutani Seisakusho Co. Takanezawa, Japan), nickel-titanium K-files (Naviflex $NT^{TM}$, Brassler, Savannah, U.S.A.), $Profile^{\circledR}$, and $ProTaper^{TM}$ (Dentsply-Maillefer, Ballaigues, Switzerland). Occlusal surface of each tooth and root apex were flattened by using diamond burs and sandpaper. Before instrumentation, a rubber stop was fixed with glue to the #10 K-files of initial working length in each tooth.(omitted)

  • PDF

The experimental study of the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. (ProTaper와 ProFile을 사용한 Hybrid instrumentation method의 근관 형성 전, 후 근관 단면적과 근관벽에서 치근외면까지 최단거리의 변화에 미치는 영향에 대한 실험적 연구)

  • Kim, Seok-Min;Park, Dong-Sung
    • The Journal of the Korean dental association
    • /
    • v.45 no.6 s.457
    • /
    • pp.362-369
    • /
    • 2007
  • The aim of this study was to investigate the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}\Delta$ curvature were scanned using X-ray microcomputed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n=10 canals ter group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with, ProTaper system (Group 2), ProFile (Group 3) or ProTaper (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Pre- and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were compared. For each level, change of cross-sectional canal are and distance to the nearest external root surface was calculated using Adobe Photoshop 6.0 and image software program. In the change of cross-sectional area, Group 4 was less than Group 2 at 3 mm and 5 mm level (p<0.05). In the difference of the distance from the canal to the root surface after canal shaping, Group 4 was least among the other groups at 7 mm level (p<0.05). According to the results, the methods using ProFile or K file only and the hybrid instrumentation technique using ProTaper and ProFile are more appropriate methods of canal preparation than ProTaper system for narrow of curved canals.

  • PDF

Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

  • Acar, Buket;Kamburoglu, Kivanc;Tatar, Ilkan;Arikan, Volkan;Celik, Hakan Hamdi;Yuksel, Selcen;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • Purpose: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. Results: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

A STUDY ON THE ROOT CANAL MORPHOLOGY CHANGE BY NICKEL-TITANIUM AND STAINLESS STEEL FILE INSTRUMENTATION USING COMPUTERIZED TOMOGRAPHY (Nickel-Titanium file과 Stainless steel file을 이용한 근관형성시 컴퓨터 단층촬영사진상의 근관형태 변화에 관한 연구)

  • So, Mun-Seop;Im, Mi-Kyung;Lee, Keon-Il;Lee, Yong-Keun;Lee, Su-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.659-669
    • /
    • 1997
  • The goals of root canal instrumentation are complete debridement of pulp tissue, removal of microbes and affected dentin, and proper cleaning and shaping of the root canal space before obturation. Instrumentation with stainless steel files has been shown to produce undesirable results in canals, regardless of the improved technique or modified file type used. Nickel-Titanium(Ni-Ti) alloy has been shown to be exceptionally elastic, having a lower bending moment and lower permanent set after torsion, compared with similar gauge stainless steel. The purpose of this study was to evaluate the change of root canal prepared by Ni-Ti rotary and stainless steel instruments. Thirty-four single rooted teeth of similar shape and canal size were divided into three groups. The teeth were scanned by computed tomography before instrumentation. In group 1, canals were instrumented using a step-back technique with K-file. In group 2, canals were prepared with K-flex file using the same technique as group 1. Group 3 was prepared with nickel-titanium(Ni-Ti) rotary instrument using a manufacture's instruction. Instrumented teeth were again scanned using computed tomography, and reformated images of the uninstrumented canals were compared with images of the instrumented canals. K-flex file and Ni-Ti file caused significantly less canal transportation than K-file in the 8mm root canal section from the apex(p<0.05). K-flex file and Ni-Ti file produced more centered canal preparation than K-file in the 2mm section(p<0.05). Ni-Ti file maintained more precisely the center of the canal than K-flex file in the 10mm section (p<0.05). There was no difference in the removed volume of canals among each groups.

  • PDF

SHAPING ABILITY OF ROOT CANAL INSTRUMENTS ON CURVED ROOT CANALS (수종 근관확대 기구의 만곡된 치근관 성형능력)

  • Kim, Myeong-Su;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.141-152
    • /
    • 1992
  • Four endodontic instruments from different manufacturers(K - file, Hedstrom - file, K - flex - file, Cavi - Endo) were used to shape 80 mesial canals of extracted posterior teeth. The instrument's ability to enlarge and shape the canals as the original canal shape was assessed by superimposing radiographs of canals obtained before and after canal shaping. The results were as follows 1. Hedstrom - file enlarged canals greater than K - file, K - flex - file, and Cavi - Endo(P<0.05). There are no differences in canal enlargement among K - flex, K - flex - file, and Cavi - Endo(P<0.05). 2. All the instruments showed no difference in canal enlargement between convex side and concave side of B point in proximal and clinical radiographic views, but at the concave side of C point canals were enlarged greater than at the convex side(proximal view of K - file: P<0.05, the others: P<0.01). 3. There was no difference m canal enlargement between convex side and concave side in proximal view of A and D points of K - file and K - flex - file(P<0.05). But in clinical view, canal enlargement at convex side of A point and concave side of D point was greater than that at concave side of A point and convex side of D point respectively. 4. Hedstrom - files showed greater canal enlargement at convex side of A points and concave side of D points (P<0.05 or P<0.01). Cavi - Endo showed no difference in canal enlargement between convex side and concave side at A and D points in proximal view(P<0.05). Bur canal enlargement was greater at concave side than at convex side of D point in clinical view. 5. K - file and Cavi - Endo showed no differences in canal enlargement between convex and concave side in proximal and clinical view (P<0.05). K - flex - file showed greater canal enlargement at concave side in proximal and clinical view(P<0.0:5). Hedstrom file showed no difference in canal enlargement between convex side and concave side in proximal view, but showed greater canal enlargement at concave side in clinical view(P<0.05).

  • PDF

A STUDY ON COMPARISON OF STAINLESS STEEL, NICKEL-TITANIUM HAND, NICKEL-TITANIUM ENGINE-DRIVEN FILE INSTRUMENTATION USING COMPUTED TOMOGRAPHY (수동형 Stainless Steel, Nickel-Titanium 및 엔진 구동형 Nickel-Titanium File의 근관형성 능력에 관한 비교 연구)

  • Lee, Hwang;Im, Mi-Kyung;Lee, Keon-Il;Lee, Yong-Keun
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.391-400
    • /
    • 1998
  • The aim of this study was to determine the shaping ability of stainless-steel K file (S-S K file), nickel-titanium K file (Ni-Ti K file) and engine driven nickel-titanium file (Quantec file) in resin simulated root canal. Computed tomography was used to evaluate the change of the root canal morphology. Thirty nine resin simulated root canal were divided into four groups (A:12, B:12, C:12, D:3). Resin simulated canals were scanned by computed tomography before instrumentation (1st C-T scan). Canals were instrumented using step back preparation technique with S-S K file in group A and Ni-Ti K file in group B. Group C was prepared with engine driven Ni-Ti file. Group D was uninstrumented to compare the 1st C-T scan images with 2nd C-T scan images of root canal. Instrumented canals were again scanned using computed tomography (2nd C-T scan), and reformated images of the uninstrumented canals were compared with images of the instrumented canals. In the sections of 2mm and 6mm from the apex, Quantec file caused significantly less canal transportation than S-S K file and Ni-Ti K file (p<0.05). Quantec file produced more centered than S-S K file and Ni-Ti K file in the sections of 2mm and 4mm from the apex (p<0.05). There was no significant difference in the removed volume of canals among the each groups (p>0.05). However the removed canal volume from the apex to 5mm were significantly higher than them from 5mm to 1mm (p<0.05) in each groups. Under the conditions of this study, preparation with Quantec file was more effective and produce more appropriate canal shapes than S-S K file and Ni-Ti K file.

  • PDF

A SCANNING ELECTRON MICROSCOPIC STUDY OF BACTERIAL ATTACHMENT IN DENTINAL TUBULES (상아세관에서 세균부착에 관한 주사전자현미경적 연구)

  • An, Jung-Mo;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.267-279
    • /
    • 1996
  • Microorganisms are implicated the endodontic treatment failures. Persistent endodontic infection may be the result of retention of microorganisms in the dentin of the root canal walls. Dentinal tubules of the root canal walls have been shown to harbor microorganisms. The purpose of this study was to investigate the invasion of microorganism into the root dentin and dentinal tubules. The effects of irrigation solutions and smear layer on bacterial colonization of root canal were evaluated using a scanning electron microscopy. Canals of extracted human teeth with single and straight canals were stepback prepared using normal saline. Tooth samples were divided into four groups according to the irrigation solutions -5 % sodium hypochlorite and normal saline-and smear layer treatment. The smear layer was removed by 5% NaOCl and 20% EDTA for 10 min respectively. After sterilization, they were incubated with each strains of Streptococcus sanguis, Enterococcus faecalis, Staphylococcus aureus and Escherichia coli. Sodium hypochlorite solution reduced the adhesion of microorganisms effectively compared to normal saline. The smear layer inhibited colonization of E. faecalis, S. aureus and E. coli in the root canals due to their blocking of dentianl tubules. But S. sanguis invaded dentinal tubules in the root canals without smear layer. It was suggested that bacterial attachment might be different according to the strains. Sodium hypochlorite inhibited bacterial attachment in the dentinal tubules dramatically. The absence or presence of smear layer affected bacterial invasion of the dentinal tubules.

  • PDF

Prevalence of Various Anatomic Variations in Cross-sectioned Apices of Maxillary Second Molars in Korean and Their Effect on Canal Cleanliness (한국인의 상악 제 2대구치 치근단면 형태에 대한 연구)

  • Park, Jinwoo;Bae, Jihyun;Choi, Yonghoon
    • The Journal of the Korean dental association
    • /
    • v.56 no.2
    • /
    • pp.84-93
    • /
    • 2018
  • Purpose: This study evaluated the apical root canal system of maxillary second molars, in which conventional endodontic treatment had failed. Materials and Methods: One hundred eighteen extracted endodontically failed maxillary second molars were examined to investigate the root canal morphology using clinical photographs. High-resolution cross-sectional images at the 3mm level from the root apices were taken to evaluate the anatomic variations and canal cleanliness. The incidence of anatomic variations and canals containing debris were evaluated statistically. Results: One (0.85%) maxillary second molar had four separate roots, while 52 (44.07%) had three separate roots. The remaining 65 (55.08%) showed 6 different types of fusion in their roots. As the number of fused roots increased from none to three, the incidence of isthmuses in the cross-sectional images increased significantly from 43.40% to 76.92% in 2-root fusion and 88.46% in 3-root fusion. In addition, the occurrence of less-cleansed canals increased from 22.64% to 38.46% and 53.85%, respectively (p<0.05). Sixty four teeth (54.24%) had 3 canals while 38(32.2%) had additional canals; most of them were located in the MB roots (81.58%). Seventy six (64.41%) had isthmuses in the apical region and 58 out of 76 were located in MB roots. Condlusions: Logistic analysis indicated that the less division of roots was associated significantly with the occurrence of insufficient cleaning during endodontic treatment (OR=1.765, p<0.05), while the presence of an additional canal showed no association.

  • PDF

A micro-computed tomographic evaluation of root canal filling with a single gutta-percha cone and calcium silicate sealer

  • Kim, Jong Cheon;Moe, Maung Maung Kyaw;Kim, Sung Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.18.1-18.9
    • /
    • 2020
  • Objectives: The purpose of this study was to evaluate the void of root canal filling over time when a calcium silicate sealer was used in the single gutta-percha cone technique. Materials and Methods: Twenty-four J-shaped simulated root canals and twenty-four palatal root canals from extracted human maxillary molars were instrumented with ProFile Ni-Ti rotary instruments up to size 35/0.06 or size 40/0.06, respectively. Half of the canals were filled with Endoseal MTA and the other half were with AH Plus Jet using the single gutta-percha cone technique. Immediately after and 4 weeks after the root canal filling, the samples were scanned using micro-computed tomography at a resolution of 12.8 ㎛. The scanned images were reconstructed using the NRecon software and the void percentages were calculated using the CTan software, and statistically analyzed by 1-way analysis of variance, paired t-test and Tukey post hoc test. Results: After 4 weeks, there were no significant changes in the void percentages at all levels in both material groups (p > 0.05), except at the apical level of the AH Plus Jet group (p < 0.05) in the simulated root canal showing more void percentage compared to other groups. Immediately after filling the extracted human root canals, the Endoseal MTA group showed significantly less void percentage compared to the AH Plus Jet group (p < 0.05). Conclusions: Under the limitations of this study, the Endoseal MTA does not seem to reduce the voids over time.

Mandibular lateral incisor with four root canals: A unique case of double tooth diagnosed using multidetector computed tomography

  • Gupta, Sunil Kumar;Gupta, Jaya;Acharya, Shashi Rashmi;Ather, Amber
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.123-128
    • /
    • 2013
  • Double tooth is a dental anomaly consequent to fusion of two or more teeth or gemination of a single tooth. This report describes a unique case of double tooth in relation to a mandibular lateral incisor exhibiting the presence of four root canals. The role of conventional radiography and advanced three-dimensional imaging techniques in the better assessment of complex root canal systems and their aid in endodontic management has also been highlighted.