• Title/Summary/Keyword: Foundation pile

Search Result 647, Processing Time 0.025 seconds

The Measurement Method of Lateral Displacement in Bridge Abutment. (교량구조물의 측방이동 측정방법에 관한 연구)

  • 장용채
    • Journal of Korean Port Research
    • /
    • v.14 no.1
    • /
    • pp.115-124
    • /
    • 2000
  • This study is a suggest a measurement method of lateral displacement, which can be used to judge the stability of bridge abutment on soil undergoing lateral movement. The abutment of bridge on soft foundation makes lateral movement due to the settlement of back fill and lateral flow. To measure the displacement of such a abutment, there are a lot of indirect method for measurement such as survey of leveling or inclinometer gauge around the abutment. But all of them are not sufficient to confirm the ground behavior and measure the exact lateral behavior of structure. As making the structure and pile cooperatively by measuring the movement of lateral displacement, for measuring the abutment displacement precisely by using the inclinometer. In this work, we try to suggest efficient measuring method of abutment displacement and its application.

  • PDF

A Study on Development of a Ground-Source Heat Pump System Utilizing Pile Foundation of a Building (건물 기초를 이용한 지중열 공조시스템의 개발에 관한 연구 (2))

  • Ryozo, Ooka;Hwang, Suk-Ho;Kentaro, Sekine;Yosuke, Shimawaki;Nam, Yu-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.155-160
    • /
    • 2005
  • To purpose of this research is to develop the numerical model for simulating performance of ground heat exchanger with high prediction accuracy. This paper describes the development of a numerical model that simulates the heat transfer between ground and circulation water in ground heat exchanger. Furthermore, we propose the estimating technique of soil properties, such as thermal conductivity, heat capacity and hydraulic conductivity, based on ground investigation. Comparison between experiment and numerical analysis based on the model developed above was conducted under the condition of the experiment in 2004. The result of analysis agreed well with the experimental result.

  • PDF

A Reinforcement Effect of Pile Foundation by Compaction Grouting System in Railroad Station Building (Compaction Grouting System에 의한 철도역사건물 파일기초보강효과)

  • Chun, Byung-Sik;Choi, Seung-Kwon;Do, Jong-Nam;Sung, Hwa-Don
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1364-1368
    • /
    • 2006
  • By the countermeasure which is caused by with railroad station ground settlement it applied a CGS in each independent foundation. The effectiveness of the ground improvement and the bearing capacity of the compaction pile has been verified by the Cone Penetration Test(CPT) and Load Test. Test result show that penetration resistance and the cone friction force increased a lot and settlement 13.475mm as the standard settlement 40.0mm appeared at below. Also uniaxial compression test result $278kg/cm^2$ as the standard $150kg/cm^2$ appeared far a lot.

  • PDF

Study on Behavior of Pile Foundation in Soft Soils (연약지반상 기초말뚝의 거동 연구)

  • Kim Dae-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.5
    • /
    • pp.428-431
    • /
    • 2005
  • In this paper, the displacement and stress of pile foundation constructed in the soft cohesive soils were measured and investigated at each construction phase. The piles belongs to compressive stress then extension due to lateral flow of soft soils. Battered piles showed different stress state according to construction direction. The lateral displacements of piles radically occurred at the embankment phase.

  • PDF

The Measurement of Lateral Displacement of Abutment Using a Inclinometer (경사계를 이용한 교대변위 계측에 관한 연구)

    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.04a
    • /
    • pp.82-90
    • /
    • 2000
  • The abutment of bridge on soft foundation makes lateral movement due to the settlement of back fill and lateral flow. To measure the displacement of such a abutment, there are a lot of indirect method for measurement such as survey of leveling or inclinometer gauge around the abutment. But all of them are not sufficient to confirm the ground behavior and measure the exact lateral behavior of structure. As making the structure and pile cooperatively by measuring the movement of lateral displacement, for measuring the abutment displacement precisely by using the incliinometer. In this work, we try to suggest efficient measuring method of abutment displacement and its application.

  • PDF

Efficiency of Pile Groups with Arrangement of Piles Using Numerical Analysis (수치해석을 통한 말뚝 배치에 따른 군말뚝 효율 분석)

  • Lee, Kichoel;Shin, Sehee;Kim, Dongwook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.523-531
    • /
    • 2021
  • In general, the foundation refers to a group pile with several single piles connected by an upper structure. However, when a load is applied to pile groups, the range of stress applied to the ground is expanded and overlapped compared with the single pile, so the overall bearing capacity may decrease. This reduction ratio of bearing capacity is referred to as the efficiency of pile groups. Therefore, in this study, the soil composition, the arrangement and spacing of group piles, and the contact characteristics between the ground and piles were set as analysis variables, and the group pile efficiency and individual pile behavior were analyzed. As a result of the analysis, the efficiency of pile groups tends to converge or decrease when the friction coefficients are increased with ground type. Through this, the optimal efficiency of pile groups can be derived. In addition, through the analysis of individual piles, the load ratio of each pile was analyzed when an upper load was applied. In the case of piles located inside group piles, the load was relatively low, and this is considered to have an influence on the internal ground.

A Study on the Optimum Design of Piled-raft Foundation Considering Pile Head Condition (말뚝두부구속조건을 고려한 말뚝지지 전면기초의 최적단면 설계)

  • Cho, Jae-Yeon;Lee, Sung-June;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.12
    • /
    • pp.31-40
    • /
    • 2010
  • This study describes the three-dimensional behavior of pile foundations based on a numerical study. A series of numerical analyses were performed for connectivity conditions between piles and cap under vertical and lateral loadings. It is shown that a fixed connection between pile and cap is able to transfer significant bending moment through the connection and increases the pile lateral stiffness and the bending moment. Based on the results obtained, it was found that the cross sectional shear force in the raft with fixed head condition was larger than that of pinned head condition. Thus, the reinforcement of pile head and thickness of the raft also increases in fixed pile head condition. From the results, it is found that the overall behavior and cross sectional forces of pile foundations is affected significantly by the pile head conditions. Furthermore, the design of pile foundations with pinned head condition was judged to be less costly and very useful for preliminary design stages.

Non-linear analysis of pile groups subjected to lateral loads using 'p-y' curve

  • Chore, H.S.;Ingle, R.K.;Sawant, V.A.
    • Interaction and multiscale mechanics
    • /
    • v.5 no.1
    • /
    • pp.57-73
    • /
    • 2012
  • The paper presents the analysis of two groups of piles subjected to lateral loads incorporating the non-linear behaviour of soil. The finite element method is adopted for carrying out the parametric study of the pile groups. The pile is idealized as a one dimensional beam element, the pile cap as two dimensional plate elements and the soil as non-linear elastic springs using the p-y curves developed by Georgiadis et al. (1992). Two groups of piles, embedded in a cohesive soil, involving two and three piles in series and parallel arrangement thereof are considered. The response of the pile groups is found to be significantly affected by the parameters such as the spacing between the piles, the number of piles in a group and the orientation of the lateral load. The non-linear response of the system is, further, compared with the one by Chore et al. (2012) obtained by the analysis of a system to the present one, except that the soil is assumed to be linear elastic. From the comparison, it is observed that the non-linearity of soil is found to increase the top displacement of the pile group in the range of 66.4%-145.6%, while decreasing the fixed moments in the range of 2% to 20% and the positive moments in the range of 54% to 57%.

Effect of Embedment Ratio and Loading Rate on Uplift Adhesion Factor of Concrete Driven Pile (근입비와 인발속도가 콘크리트 항타말뚝의 인발부착계수에 미치는 영향)

  • Kim Jong-In;Park Jeong-Jun;Shin Eun-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.4
    • /
    • pp.367-371
    • /
    • 2005
  • Pile foundations are utilized when soil is so weak that shallow foundations are not suitable or point load is concentrated in small area. Such soil can be formed by the land reclamation works which have extensively been executed along the coastal line of southern and western parts of the Korean Peninsula. The working load at pile is sometimes subjected to not only compression load but also lateral load sad uplift forces. But in most of the practice design, uplift capacity of pile foundation is not considered and estimation of uplift capacity is presumed on the compression skin friction. This study was carried out to determine that the effect of embedment ratio and loading rate on uplift adhesion factor of concrete pile driven in clay. Based on the test results, the critical embedment ratio is about 9. Adhesion factor is constant under the critical embedment ratio, and decreasing over the critical embedment ratio. Also, adhesion factor is increased with the loading rate is increased.

Performance-based comparison of energy pile of various heat exchange pipe arrangement by in-situ thermal response test (현장 열응답 시험을 통한 에너지파일의 열교환파이프 배열 방식에 따른 성능 비교)

  • Min, Sunhong;Koh, Hyungseon;Yoo, Jaihyun;Jung, Kyoungsik;Lee, Youngjin;Choi, Hangseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.196.1-196.1
    • /
    • 2011
  • In this study, a test bed was constructed in order to evaluate thermal efficiency of the energy pile which carries out combined roles of a structural foundation and of a heat exchanger. The energy pile in this study is designed as a large-diameter drilled shaft equipped with the heat exchange pipes which configures a W-shape and an S-shape. The drilled shaft reached to the depth of 60 m whilst the heat exchange pipes were installed to about 30 m deep from the ground surface. The W-shaped and S-shaped heat exchange pipes were installed in the opposite sections of the same drilled shaft. In-situ thermal response tests were performed for both the shapes of heat exchange pipes. To avoid underestimating the thermal performance due to hydration heat of concrete inside the drilled shaft, the in-situ thermal response tests for the energy pile were performed after four weeks since the installation of the energy pile.

  • PDF