• Title/Summary/Keyword: Fouling surface

Search Result 279, Processing Time 0.03 seconds

Effect of Organic Melecular Weight and Functional Group on Membrane Fouling (막오염에 미치는 유기물 분자량 분포특성 및 화학적 구조특성)

  • Jung, Chul-Woo;Son, Hee-Jong;Shin, Hyun-Sool;Sohn, In-Shik
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.669-676
    • /
    • 2007
  • The raw water was fractionated into hydrophobic (HPO), transphilic (TPI), and hydrophilic portions (HPI) using XAD resins. The raw water DOC contains 39% of hydrophilics, 43% of hydrophobics, and 18% of transphilics. When fractionated NOM (natural organic matter) was passed through hydrophilic membrane with 100 kDa, hydrophobic portion (HPO) caused the most fouling and hydrophilic portion (HPI) caused the least fouling. This could be related to size and adsorption capability of organics. Small sized organics would pass through membrane pores, but large sized organics would be attracted to either membrane pores or surface, which led to the fouling. An effect of membrane pore size on membrane fouling is related to the availability of organics at membrane pores. As the pore size became larger, the more organics were transported into the membrane pore. Some organics caused pore blocking, and others caused pore adsorption, which resulted in membrane fouling. Membrane material is also important for membrane fouling. More fouling occurred at hydrophobic membrane than hydrophilic membrane regardless of its pore size. Hydrophobic interaction caused more fouling at hydrophobic membrane.

Effect of Cathode in Electrochemical Reaction for Treating Ballast Water (선박평형수 처리를 위한 전기화학 반응에서 음극의 영향)

  • Kim, Dong Seog;Park, Hye Jin;Yoon, Jong Mun;Park, Yong Seok;Park, Young Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1175-1182
    • /
    • 2014
  • In this study, we examined the effect of cathode from electrolysis reactor for treating ballast water. We are going to select a suitable cathode for seawater electrolysis after considering the effect on the generation of the oxidant of cathode and the electrode deposition materials adhering to the surface of cathode. Anode is Ru-Ti-Pd electrode and cathode are Ti, Pt, JP520 (Ni-Pt-Ce) electrodes. Using the cathode of the three types, experiments were conducted to examine the effects of TRO (total residual oxidants) generation concentration and RNO (N, N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation concentration (in 1, 35 psu), ohmic drop, FESEM(field emission scanning electron microscope) observation of cathode surface and EDX (energy dispersive X-ray spectroscopy) measurements of attached fouling material. The results showed that TRO generation concentration and RNO degradation concentration in according to each type of cathode are not different. The attached fouling materials were observed on the surface of Ti and the JP520 electrode by the observation of SEM after electrolysis for two hours, but it was not observed on the surface of Pt electrode. When considering the surface ohmic drop of cathode and the attached fouling materials, Pt electrode was judged as the excellent cathode.

Application of electro-coagulation for the pretreatment of membrane separation of anaerobic digestion effluents (혐기성 소화액의 막분리를 위한 전기응집 전처리 연구)

  • Kim, Shin-Young;Chang, In-Soung;Kim, Jang-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4665-4674
    • /
    • 2014
  • The aim of this study was to confirm the feasibility of the electro-coagulation process as a pre-treatment for the membrane separation of anaerobic digestion effluents to minimize membrane fouling. The reduction of membrane fouling was evaluated according to the number of electrodes (immersed surface area of electrodes), current density and contact time. In the case of the small surface area of electrodes, the increased electric field strength resulted in a soluble COD increase due to the destruction of the microbial flocs and/or cells, whereas large changes in the soluble COD were not observed in the case of the high surface area of electrodes. On the other hand, the T-P concentration decreased as a result of the precipitation of aluminum ions and phosphates. The membrane permeation flux increased and the fouling resistance (Rc+Rf) decreased with increasing electric current density. Although the particle size of the anaerobic digestion effluent increased slightly, it was not related directly to the reduced fouling phenomena. The main mechanism for the enhanced flux was attributed to the inorganic particulate produced during electrocoagulation, such as $AlPO_4$, which acted as a dynamic membrane deposited on the membrane surface.

A fouling mitigation device for a wastewater heat recovery heat pump system using a bubbling fluidized bed with cleaning sponge balls (버블 유동층과 세정 볼을 이용한 폐수 열원 히트펌프 시스템 증발기의 관 외측 오염 저감 장치에 관한 연구)

  • Kim, Jong-Soo;Kim, Do-Bin;Kim, Jun-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.152-156
    • /
    • 2016
  • Wastewater heat recovery heat pump systems use heated wastewater from public baths or factories as the heat pump's heat source. Generally, this system uses a bare tube evaporator. In the heat transfer process from wastewater to refrigerant, thermal resistance is caused primarily by fouling deposits on the outside surface of tube. Fouling directly increases thermal resistance and decreases heat pump efficiency. Thus, it is desirable to eliminate fouling. In this study, we fabricated a fouling mitigation device using a bubbling fluidized bed with cleaning sponge balls in the wastewater bath. Experimental conditions were as follows: $20^{\circ}C$ cold-water temperature, $40^{\circ}C$ wastewater temperature, 100 L/h cold water flow rate, and $0.161m^2$ heat exchanger surface area. Experimental results showed that the thermal resistance of fouling decreased by 56% with the fluidized bed alone and by 86% with both the fluidized bed and cleaning sponge balls.

A Study on the Effect of Scale Roughness attached Surface of Heat Exchangers (표면에 부착되는 스케일의 조도가 열교환기 성능에 미치는 영향에 관한 연구)

  • Kim, Min-Soo;Choi, Nag-Jung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.235-242
    • /
    • 2010
  • An experimental investigation has been conducted to clarify roughness effects of geothermal water scale deposited onto a heating surface upon its forced convection heat transfer characteristics. Examined was a circular cylinder, on which particles of silica scale having five different sizes are uniformly distributed. The Reynolds number was varied from 13000 through 50000. Local and mean heat transfer characteristics were measured as functions of particle size and Reynolds number. Subsequently the mean fouling resistance was estimated from those results, and its characteristics are clarified. It was found that the heat transfer of cylinders greatly varies with the fouling of geothermal water scale, especially its scale height. Further, the local and average Nusselt numbers strongly depend upon the cylinder spacing and the Reynolds number.

Micro-Filtration Performance of Metal Membrane md Fouling Reduction by Intermittent Ozonation (금속 막의 정밀 여과 특성 및 간헐적 오존 처리에 의한 막 오염 저감)

  • 김종오;정종태
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.66-74
    • /
    • 2004
  • Total resistance of membrane in a micro-filtration system using a metal membrane was mainly attributed to the permeate resistance of cake layer($R_c$), which was formed by deposited particles from the physico-chemical interactions of solids on membrane surface. Intermittent back ozonation was highly effective than the air backwashing for fouling reduction. As far the operational effect, under same ozone injection, the increase of gas flow-rate was more favorable than the increase of injection time far the recovery of permeation flux. As the filtration time was longer, the effect of flux recovery by intermittent back-ozonation decreased. Therefore, it is preferable to operate membrane cleaning before the foulant is consolidated on membrane surface.

A Study on Fouling Characteristics and Applicability of Fouling Reducer in Submerged MBR Process (침지형 MBR공정에서 파울링 특성과 파울링 완화제의 적용성에 관한 연구)

  • Park, Jun Won;Park, Hong June;Kim, Min Ho;Oh, Yong Keol;Park, Chul Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.371-380
    • /
    • 2013
  • Though MBR process has many advantages, the greatest risk factors in operating MBR process are occurrence of membrane fouling and decrease of flux. It is very difficult to find exact mechanism due to complex influence by many effects, although there have been recently many studies of membrane fouling. The purposes of this study are firstly evaluating bioreactor of lab-scale and micro-filtration hollow fiber membrane, secondly investigating correlation between foulants affecting membrane performance and membrane fouling, and lastly evaluating various parameters affecting fouling and applicability of membrane fouling reducer. This study found that TMP was increasing rapidly and showed 0.32 bar and the average of flux was 88 LMH. EPS concentration tends not to change much above MLSS concentration (6,000 mg/L). However, EPS concentration variation is wide below MLSS concentration (6,000 mg/L). Also, from results of membrane surface condition and element analysis using SEM/EDX, carbon and fluorine were founded to be the highest percentage in membrane because of characteristics of membrane material. In operating continuously, inorganic fouling was generated by increase of these inorganic substances such as $Al^{3+}$ and $Mg^{2+}$. Lastly, the best filtration performance was obtained for 0.03 mg MFR/mg MLSS by results of particle size, zeta potential, $SCOD_{cr}$, EPS and MLSS concentration.

Evaluation of RO Process Feasibility and Membrane Fouling for Wastewater Reuse (하수처리수 재이용을 위한 RO 공정의 타당성 및 막오염 평가)

  • Hong, Keewoong;Lee, Sangyoup;Kim, Changwoo;Boo, Chanhee;Park, Myunggyun;An, Hochul;Hong, Seungkwan
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.289-296
    • /
    • 2010
  • The purpose of this study is to evaluate various pre-treatment methods and proprieties of water quality for wastewater reuse using reverse osmosis (RO) processes. Secondary effluents were sampled from wastewater treatment plants and lab scale pre-treatments and RO filtration test were conducted systematically. Specifically, different types of pre-treatments, such as coagulation, microfiltration and ultrafiltration, were employed to evaluate the removal efficiency of particle and organic matters which may affect the membrane fouling rate. RO process was later added to eliminate trace amounts of remaining organic matters and salt from the raw water for wastewater reclamation. The permeate through the RO process satisfied water quality regulations for industrial water uses. The experimental results showed that the initial fouling tendency differed not only by the feed water properties but also by the membrane characteristics. Membrane fouling was greater for the membranes with large surface roughness, regardless of the hydrophobicity and zeta potentials. Thus both careful consideration of pre-treatment options and proper selection of RO membrane are of paramount importance for an efficient operation of wastewater treatment.

Preparation and Characteristics of Fouling Resistant Nanofiltration Membranes (내오염성 나노여과막의 제조 및 특성)

  • Kim, No-Won
    • Membrane Journal
    • /
    • v.17 no.1
    • /
    • pp.44-53
    • /
    • 2007
  • The primary objective of this study is to increase the extent of water flux and fouling resistance of nano-filtration or reverse osmosis membranes. This study was performed to investigate the effect of surface characteristics of silane coated membranes on modified fouling index. Commercial polyamide composite RO membrane (RE1812-LP) and NF membrane (ESNA4040-LF) were treated with silane coupling agents in ethanol at five different concentrations. The silane coupling reagent, aminopropylmethoxydiethoxysilane, contains one aminoalkyl and three alkoxy groups. The hydrophilic effect of aminoalkyl group of APMDES on the permeability and fouling resistance of the modified membrane was examined. The surfaces of the modified membranes were characterized by FE-SEM, contact angle analyzer, and zeta potentiometer in order to confirm successful sol-gel methods. The modified NF membranes showed significantly enhanced water flux and fouling resistance without a decrease in salt rejection in divalent ionic feed solution.