• 제목/요약/키워드: Fouling surface

검색결과 279건 처리시간 0.028초

Microalgal-MBR과 Bacterial-MBR 운전에 있어 EPS 조성이 Fouling 발생특성에 미치는 영향 (Effects of EPS Composition on Fouling Characteristics at the Microalgal-MBR and Bacterial-MBR Process)

  • 김태연;이수현;권수민;황선진
    • 한국물환경학회지
    • /
    • 제39권2호
    • /
    • pp.175-180
    • /
    • 2023
  • The aim of this study was to compare the fouling characteristics of Extracellular polymeric substances (EPS) secreted by Chlorella vulgaris with the case of Bacterial-MBR (BMBR), Microalgal-MBR (MMBR) for advanced wastewater treatment using the Laboratory scale, in order to suggest a method to minimize fouling in MMBR by identifying the effects of amounts and compositions of EPS secreted by C. vulgaris and bacteria in the activated sludge on fouling. Contrary to expectations, fouling occurred relatively severely in the MMBR from the beginning of the operation than in the BMBR. Reasons for such a fouling pattern were considered to be the effect of C-EPS, which accumulates on the membrane surface of MMBR 30 times more than that on the membrane surface of activated sludge (BMBR). In this respect, according to the results of this experiment and a comparative review of several previous studies, it was confirmed that unlike activated sludge, in which the ratio of P-EPS was relatively higher than that of C-EPS, in case of C. vulgaris, the ratio of C-EPS to P-EPS was relatively higher than that in case of activated sludge. This was presumed to be the main cause of the significant fouling phenomenon in MMBR. However, an increase in TMP with increasing C-EPS concentration was not observed.

냉각수로 하천수를 이용하는 열교환 시스템내 Fouling 형성에 관한 연구 (A Study on the Formation of Fouling in a Heat Exchanging System for HAN-River Water as Cooling Water)

  • 성순경;서상호;노형운;조영일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1473-1478
    • /
    • 2003
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When scale deposits in a heat exchanger surface, it is traditionally called fouling. The objective of the present study is to investigate the formation of fouling in a heat exchanging system. A lab-scale heat exchanging system is built-up to observe and measure the formation of fouling experimentally. Water analyses are conducted to obtain the properties of HAN river water. In the present study a microscopic observation is conducted to visualize the process of scale formation. Hardness of HAN-river water is higher than that of tap water in Seoul.

  • PDF

실험실용 판형 열교환 시스템에서 가시화를 이용한 파울링 기구 해석 (Analyses of Fouling Mechanism using Visualization Techniques in a Lab-scale Plate-Type Heat Exchanging System)

  • 성순경;서상호;노형운
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.349-354
    • /
    • 2004
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When the scale deposits in a heat exchanger surface, it is conventionally called fouling. The objective of the present study is to analyze the process of the fouling formation in a heat exchanger according to different types of water using visualization techniques. In order to experimentally investigate the formation of the fouling, this study built a lab-scaled heat exchanging system. Using the visualization techniques of Scanning Electron Microscopy (SEM) and X-Ray diffraction method, the three dimensional configurations of the fouling formation could be successfully obtained. Based on the experimental results, it was found that the configurations of the fouling formation were different when using tap water compared to river water.

열교환장치의 냉각수 계통에서 세라믹 볼의 파울링 저감효과 (Effect of Fouling Mitigation for Ceramic Ball in Cooling Water System of Heat Exchanger)

  • 서상호;성순경
    • 대한기계학회논문집B
    • /
    • 제31권4호
    • /
    • pp.330-334
    • /
    • 2007
  • The objective of this study was to investigate the effecs of fouling mitigation for ceramic ball in cooling water system experimentally. The devices filled with ceramic balls were connected to the bypass line of the heat exchanging system. Cooling water in the heat exchanging system was artificial water. To visualize the formation of fouling on the heat transfer surface a number of images were obtained using a CCD camera with real-time microscopy. Fouling resistances and overall heat transfer coefficients were measured in order to analyze fouling mitigation effects. We found that the ceramic ball devices for artificial water reduced the formation of fouling compared to the no-mitigation devices.

열교환기 모델내 하천수와 시수의 Fouling 특성 비교 (A Comparative Study on the Fouling Characteristics of River and Tap Water in a Heat Exchanging Model)

  • 성순경;서상호;노형운
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.49-54
    • /
    • 2003
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When scale deposits in a heat exchanging surface, it is traditionally called fouling. The objective of the present study was to compare the fouling characteristics of river and tap water in a heat exchanging model. FromtheSEM analyses for tap water the $calciteformofCaCO3_{3}$ was formed. For river water, however, the $aragoniteCaCO_{3}$ wasformed.In order to investigate velocity effects on the fouling characteristics in the heat exchanging model, the inlet velocity was varied with 0.5, 1.0 and 1.5 m/s, respectively. The fouling characteristics of river water were quite different from those of tap water. For the case of the 'velocity of 1.5m/s', the overall heat transfer coefficient was reduced up to 26% than that of the 'velocity of 0.5m/s'

  • PDF

전류밀도와 전해질의 pH가 음이온교환막의 막 오염에 미치는 영향 (Effect of Current Density and pH of Electrolyte on Anion-Exchange Membrane Fouling)

  • 최재환
    • 대한환경공학회지
    • /
    • 제27권9호
    • /
    • pp.965-969
    • /
    • 2005
  • 이온교환막 공정의 중요한 운전인자인 전류밀도와 전해질의 pH가 막 오염에 미치는 영향을 연구하였다. 휴믹산 100 mg/L를 포함하고 있는 NaCl 용액에서 Neosepta AMX (Tokuyama Soda, Japan) 음이온교환막의 막 오염 현상을 관찰하였다. 한계전류밀도(LCD) 전 후 영역의 전류를 공급하면서 이온교환막의 전기저항 변화를 측정하여 막 오염 현상을 분석하였다. 실험결과 LCD 이하에서는 전류밀도의 변화가 막 오염에 큰 영향을 미치지 않았다. 그러나 LCD 이상의 전류밀도에서는 막 오염이 심각하게 진행되는 것으로 나타났다. 실험 후 휴믹산에 오염된 막에 대한 전류전압 곡선에서도 LCD 이상에서 실험한 경우에 막 오염으로 전기저항이 증가하고 LCD가 감소한 것을 알 수 있었다. 또한 휴믹산이 포함된 전해질 용액의 pH를 산성 조건으로 조정한 후 실험한 결과 pH가 감소할수록 막 오염이 증가하는 것으로 나타났다. 이 결과로부터 막 오염이 휴믹산의 표면 전하에 의한 것보다 물리화학적 성질에 더 큰 영향을 받는다는 것을 알 수 있었다.

해석적 방법을 통한 압축기의 파울링 해석 (Prediction of Compressor Fouling Using an Analytic Method)

  • 송태원;김동섭;김재환;노승탁
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.176-183
    • /
    • 2000
  • The performance of gas turbines decreases as their operating hours increase. Compressor fouling is the main reason for this time-dependent performance degradation. Airborne particles adhere to the blade surface and results in the change in the blade shape. It is difficult to exactly analyze the mechanism of the compressor fouling because the growing process of the fouling is very slow and the dimension of the fouled depth is very small compared with blade dimensions. In this study, an analytic method to predict the motion of particles and their deposition inside axial flow compressors is proposed. The analytic model takes into account the blade shape and the flow within the blade passage. Comparison of simulation result with field data shows the feasibility of the model. Influence of the particle distribution on the compressor fouling is also examined.

  • PDF

PVDF막 표면에 폴리비닐알코올 코팅을 통한 분리막의 투과특성 및 막오염 제어 (Membrane Permeation Characteristics and Fouling Control through the Coating of Poly(vinyl alcohol) on PVDF Membrane Surface)

  • 장한나;김인철;이용택
    • 멤브레인
    • /
    • 제24권4호
    • /
    • pp.276-284
    • /
    • 2014
  • 본 연구에서는 소수성 PVDF막 표면에 중성 친수성 고분자인 Poly(vinyl alcohol) (PVA)를 코팅한 후 순수 투과도를 측정하고 대표적인 단백질 오염물질인 bovin serum albumin (BSA)에 대하여 파울링 실험을 수행하였다. BSA 용액 20 ppm 조건에서 파울링 실험을 수행한 결과, 코팅 전 막에 비하여 순수 투과도는 감소하였지만 내오염성은 현저히 증가됨을 알 수 있었다. 코팅된 PVA의 분자량이 커질수록 순수 투과도는 감소하였으나, 내오염성이 증가하는 경향을 보였다. 또한, 코팅된 PVA의 농도가 높아질수록 순수 투과도는 감소하였고, 내오염성이 증가하였다. 이는 접촉각과 AFM 측정 결과와 관련하여 코팅 후 막 표면에 친수성의 증가와 거칠기가 감소했기 때문으로 여겨진다.

표면 코팅 입자에 의한 석탄화력 발전용 보일러 파울링 수치적 연구 (Computational Study of Fouling Deposits Due to Surface-Coated Particles in Coal-Fired Power Utility Boilers)

  • 이병은;유갑종;신세현;권순범
    • 대한기계학회논문집B
    • /
    • 제26권3호
    • /
    • pp.474-481
    • /
    • 2002
  • Fouling deposits due to surface-coated particles have been calculated using CFD techniques. The sticking probabilities of the surface-coated particles are also evaluated on the basis of an energy balance. The sticking probabilities of the deposit surface are also included in the prediction of the deposition occurring through the multiple impaction of particles with the deposit surface. The sticking probability of an impacting particle is expressed in terms of such parameters as particle viscosity, surface tension, impact velocity, impact angle and the thickness of the sticky layer on a particle. Particulate behavior around a tube in cross flow was studied using the Lagrangian approach. Three important parameters i.e. impact velocity, impact angle, and particulate concentration, were used in the prediction of deposition rate. The computational predictions were found to be in good agreement with the experimental data.