• 제목/요약/키워드: Forming angle composite column

검색결과 2건 처리시간 0.014초

충전형 합성보와 포밍앵글 기둥 접합부의 내진성능에 대한 실험적 평가 (Experimental Evaluation on Seismic Performance of Filled Composite Beam - to - Forming Angle Composite Column Connections)

  • 김형섭;이경구;구지모
    • 한국지진공학회논문집
    • /
    • 제20권1호
    • /
    • pp.71-77
    • /
    • 2016
  • In this study, the seismic performance of connections between filled composite beam (CG beams) and forming angle composite (FAC) column was experimentally evaluated. First, the bending tests were conducted on two CG beams and the axial tests were conducted on two FAC columns. Then, based on these preliminary test results, the cyclic loading test were performed on two interior connections between CG beam and FAC column. The main difference of two specimens is the plate shape of the CG beam. The test results showed that both specimens achieved the maximum story drift capacity over 0.04 radian which is required for special moment frame.

신형상 U형 하이브리드 합성보와 기둥 접합부의 내진성능에 관한 연구 (Study on the Cyclic Seismic Testing of U-shape Hybrid Composite Beam-to-Composite Column Connections)

  • 김성배;김상섭;유덕수
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.47-59
    • /
    • 2013
  • 본 연구는 신형상 U형 합성보의 1차 휨실험에 연이은 2차 연구로 U형 합성보와 기둥 접합부의 내진성능시험이다. 실험 변수는 기둥의 종류와 보 춤, 보 상부 플레이트 연속유무, 보 단부 철근 수 등으로 3개의 실험체를 제작하였다. 기둥의 종류는 철골 철근콘크리트 기둥과 CFT 형상의 ACT기둥이며, 보 춤은 300, 500(mm)이다. 접합부상세는 일반적으로 많이 적용하고 있는 짧은 브라켓을 활용한 볼트 접합부이다. 실험결과 변형능력은 2~4(%)의 층간변위각을 확보하였으며, 최대모멘트는 부휨모멘트의 경우 공칭모멘트 이상의 내력이 나타났다.