The Influence of Forest Fire Simulation on the Properties of Polymer Insulators

  • Lee, Won-Kyo;Choi, In-Hyuk;Lee, Dong-Il;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권5호
    • /
    • pp.161-164
    • /
    • 2009
  • Forest fire simulation tests were performed with polymer and porcelain insulators at GOCHANG Power Testing Center. These tests consisted of open flames causing a temperature rise of up to $600{\sim}800^{\circ}C$ measured at the insulator surfaces. Mechanical and electrical characteristics such as the specific mechanical load, the low frequency dry flashover voltage and the impulse flashover voltage were analyzed for the polymer insulators before, during and after the simulation tests and then compared to the porcelain insulators. At the end of the fire simulation tests, there was no detrimental deterioration of any of the insulators. All the insulators passed the KEPCO specification criteria. This study showed that the forest fire simulation had no impact on the polymer insulators.

통전 중 산불에 노출된 가공송전선의 온도 및 장력 변화 거동 (Temperature and Load Change behavior of Overhead Conductor under loading current due to Forest Fire)

  • 김병걸;장용호;김상수;한세원
    • 한국전기전자재료학회논문지
    • /
    • 제22권4호
    • /
    • pp.366-371
    • /
    • 2009
  • The authors have published several technical reports on the deterioration of conductor due to forest fire in series so far. This is because even we have been experiencing hundreds of forest fires every year, no systematic research on conductor which is very vulnerable to fire have been fulfilled. This paper describes the sag-tension behavior of conductor under loading current normally when only partial area of a long conductor is exposed to fire. Temperatures of Overhead Conductor were different with measurement position. When the partial area of conductor was heated up to $500^{\circ}C$, 20 % of permanent tension loss was observed. This results in the increase of sag of 1.5 m when span is 300 m. The other results will be presented in the text.

산불에 열화된 ACSR 전선의 기계적 특성 검토 (Mechanical characteristic of ACSR Transmission lines by forest fires)

  • 강지원;장태인;홍동석;박창기;방항권;김영달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.506-508
    • /
    • 2003
  • In the case of a fire in the mountains, steel wires coated with zinc and aluminum wires of those power cables exposed to the fire or near around will be deteriorated by the blaze and the high temperature. This paper shows the experimental results that apply to a new wire by an artificial flame-maker and results including the intensity of extension and wrench for a conductor. In addition, there's been an experiment and analysis about the mechanical characteristics of the wire of ACSR $480mm^2$ which was removed from A T/L by a forest fire. Then, the database will be made to predict the state of deteriorated wires by a forest fire using those two data, and data necessary to diagnose the life state of an ACSR wire affected by a forest fire will be given.

  • PDF

산불피해 현장답사를 통한 연소면적 산출 연구 - 임실, 경주 산불을 중심으로 - (The Study of Burned-Area Analysis Method for Forest-fire Damaged Area - Investigation for ImSil County, GyeongJu City -)

  • 강서영;이정윤;김홍
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.176-181
    • /
    • 2012
  • In this research the 2009 spring occurred during forest fire ImSil and research destination GyeongJu has been selected. Research in the field of the target time exploratory Boundary Data through after air photos, satellite photos and topographic map by using the combustion area was calculated. 2009 March 1-forest fire occurs on the day of the weather information and weather changes wildfire in the check in any affected. Study research destination of combustion is ImSil 161 ha, GyeongJu 270.93 ha. The impact of the weather-temperature dry weather forest fires this favorable situation to occur and the wind directions and the spread of the mountain wind speed was less impact has no arguments.

산불에 노출된 가공송전선의 기계적 및 전기적 특성 거동 (Mechanical and Electrical Properties of Overhead Conductor due to Forest Fire)

  • 김병걸;장용호;김상수;한세원
    • 한국전기전자재료학회논문지
    • /
    • 제21권11호
    • /
    • pp.1042-1048
    • /
    • 2008
  • Forest Fire can cause a serious damage to overhead conductors. Therefore, the detailed investigation for the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is very much important to maintain transmission line safely. Especially, this paper describes the changes of mechanical and electrical properties of flame exposed conductor. Overhead conductors temperature were almostly 55$\sim$65% of ambient temperature. Tensile Strength decreased according to incerase of Forest Fire temperature. The detailed will be given in the text.

154kV 송전용 폴리머 애자의 산불에 대한 누설전류 및 온도 특성 (A Characteristics of Leakage Current and Temperature on Forest Fire of EHV Polymer Insulator for 154KV T/L)

  • 최인혁;최장현;박준호;이동일;김태영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.517-518
    • /
    • 2006
  • In this paper, to understand the effect of forest fires on polymer insulators for transmission lines, it was observed the aging of the housing surface of the polymer insulators. And, this paper shows the way how to create the artificial field testing in order to simulate forest fire. As the results of, maximum leakage current peaks by influence of flame increased from 1[mA] to 1.4[mA], and SEM results show the inorganic component on the housing surface because the organic component matters disappeared. Therefore, the case of exposed by forest fire, polymer insulator can be used in the early stage, but an exchange needs active countermeasure to be stabilize power delivery.

  • PDF

2019년 강원도 대형산불지역의 열해 피해로 인한 피해강도 변화 탐색 (Change Detection of Damaged Area and Burn Severity due to Heat Damage from Gangwon Large Fire Area in 2019)

  • 원명수;장근창;윤석희;이훈택
    • 대한원격탐사학회지
    • /
    • 제35권6_2호
    • /
    • pp.1083-1093
    • /
    • 2019
  • 본 연구는 2019년 발생한 강원 고성·속초, 강릉·동해 대형산불 직후 산불의 영향으로 수목의 수관부가 완전 연소되거나, 직간접적인 열해 피해로 인해 고사되어 가는 과정을 다목적실용위성(KOMPSAT-2호, 3호) 영상자료를 활용하여 시간경과에 따른 산불 피해강도별 피해면적의 변화를 정확하게 산정하는데 목적이 있다. 피해강도별 피해면적 산출을 위해 산불 직후 위성영상자료와 15~18일 경과 후의 두 시기 영상자료를 이용하였다. 산불 직후와 일정기간 경과 후 촬영한 위성영상자료의 산불피해강도 분석결과는 '수관전소(Extreme)' 지역에서는 큰 변화가 없었으나 '수관열해(High)' 지역과 '지표화(Low)' 지역에서는 큰 면적차이를 보였다. 이러한 피해강도의 차이에 따른 피해면적의 변화는 산불 영향으로 인해 수관부가 서서히 갈색으로 변색되어 가는 과정에 의한 것으로 판단된다. 산불피해지역의 위성영상 분석결과와 현장사진, 드론 영상을 종합해 볼 때 산불 직후 3~4일 후부터 수관부의 갈변현상(Browning)이 나타나고 10~15일 경과 후엔 수관부의 갈변현상이 뚜렷해지는 것을 알 수 있었다. 본 연구결과를 통해 향후 대형산불지역의 신속한 피해면적 파악은 물론 수관열해로 인한 고사 기작을 파악함으로써 산불피해지 복구계획 수립을 위한 의사결정의 기초자료로 활용할 수 있을 것으로 사료된다.

동해안 산불 피해지에서 산불 후 경과 년 수에 따른 식생 구조의 발달 (Development of Vegetation Structure after Forest Fire in the East Coastal Region, Korea)

  • 이규송;정연숙;김석철;신승숙;노찬호;박상덕
    • The Korean Journal of Ecology
    • /
    • 제27권2호
    • /
    • pp.99-106
    • /
    • 2004
  • 동해안 산불피해지역 중 시급한 복구계획을 요하는 사면지역에 대한 산불 후 경과 년 수에 따른 일반적인 식생발달 모형을 개발하였다. 또한 산불피해지역을 관리하기 위한 기법 개발에 사용될 매개변수로서 식생지수들의 발달모형을 제시하였다. 산불 피해지역에서 맹아로 재생하는 목본 식물량을 추정하기 위하여 총 17종의 상대 생장식을 구하였다. 산불 경과 후 교목층, 아교목층, 관목층 및 초본층의 4층 구조를 갖춘 완전한 형태의 숲으로 회복되는데 약 20년이 경과해야 하는 것으로 추정되었다. 산불 후 경과 년 수에 따라 최상층부 식생의 키, 목본의 기저면적 및 지상부 목본 식물량은 직선적인 증가 경향을 나타내었고, 전체 지상부 식피율과 낙엽층은 대수적인 증가 경향을 나타내었다. 식생지수 중 Ivc와 Ivcd는 산불 후 경과 년 수에 따라 대수적인 증가 경향을 그리고 Hcl과 Hcdl은 직선적인 증가경향을 나타내었다. 특히 산불 피해 후 2차 재해가 예측되는 초기 5년차 이내에서는 모든 식생 요인들이 입지요인이나 지력에 따라 공간적 이질성이 큰 것이 확인되었다. 식생 지수 중 Ivc와Ivcd는 산불 초기의 공간적 이질성을 표현하기에 적당한 지수이었고, Hcl과 Hcdl은 장기적인 식생구조의 발달을 예측하는데 유용한 지수로 판단되었다.

산불 피해목의 재질변화에 관한 연구(II) - 산불 피해 소나무의 경시적 재질변화 - (Variation of Material Properties of Fire-killed Timber - Impact of Time on Degradation of Mechanical Properties -)

  • 박정환;박병수;김광모;이도식
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권1호
    • /
    • pp.30-35
    • /
    • 2008
  • 동해안 지역에서 산불로 고사된 소나무의 5년에 걸친 경시적 재질 변화를 역학성능을 중심으로 조사하였다. 고사에 따른 재질열화로 가장 크게 영향 받는 역학성능은 충격 휨 흡수에너지였다. 따라서 고사 초기의 재질변화를 예측하는 지표로 활용이 가능할 것으로 밝혀졌다. 고사 경과에 따라 변재의 재질열화가 심재에 비해 두드러지게 진행되었다. 열화의 정도는 충격 휨 흡수에너지가 가장 컸으며 압축강도가 가장 작았다. 고사 이후의 외관 변화와 역학성능의 열화진행 정도로 볼 때 산불피해 소나무의 유효한 활용을 위한 적정 벌채 시기는 산불발생 1년 이내가 바람직한 것으로 밝혀졌다.

Forest Fire Impacts in Thailand

  • Akaakara, Siri
    • 한국동물학회:학술대회논문집
    • /
    • 한국동물학회 2000년도 한국생물과학협회 학술발표대회
    • /
    • pp.84.1-84
    • /
    • 2000
  • No Abstract, See Full Text

  • PDF