• Title/Summary/Keyword: Forearm injuries

Search Result 27, Processing Time 0.021 seconds

Revisit of the Extended Indications and Clinical Utilities of Arterialized Venous Flap for Hand Reconstruction (수부 재건을 위한 동맥화 정맥 피판의 확장된 적응증과 임상적 유용성의 재조명)

  • Woo, Sang-Hyun;Kim, Kyung-Chul;Lee, Gi-Jun;Ha, Seung-Han;You, Sun-O;Kim, Joo-Sung
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.1-13
    • /
    • 2005
  • Purpose: The purpose of this study is to present extended indications for the use of arterialized venous flaps in reconstructing soft tissue, tendon, nerve, blood vessel, and composite tissue defects of the hand of various sizes based on researches and clinical experiences of the authors. Moreover, procedures to achieve complete flap survival and postoperative results are presented. Materials & methods: This study is based on 154 cases of arterialized venous flaps performed to reconstruct the hand during the past 11 years. The most common cause of injury was industrial accidents with 125 cases. One hundred thirty patients or 84% of the cases had emergency operation within 2 weeks of the injury. The flaps were categorized depending on the size of the flap. Flaps smaller than $10\;cm^2$ were classified as small (n=48), those larger than $25\;cm^2$ classified large (n=42) and those in between medium (n=64). Classified according to composition, there were 88 cases (57.1 %) of venous skin flaps, 28 cases of innervated venous flaps, 15 cases of tendocutaneous venous flaps, which incorporated the palmaris longus tendon, for repair of extensor tendons of the fingers, and 17 cases of conduit venous flaps to repair arterial defect. There were 37 cases where multiple injuries to multiple digits were reconstructed. Moreover, there were 6 cases of composite tissue effects that involved soft tissue, blood vessels and tendons. The donor sites were ipsilateral forearm, wrist and thenar area, foot dorsum, and medial calf. The recipient sites were single digit, multiple digits, first web space, dorsum and palm of hand, and wrist. Results: There were seven cases (4.5%) of emergent re-exploration due to vascular crisis, and 3 cases of flap failure characterized by more than 50% necrosis of the flap. The survival rate was 98.1 % (151/154). In small flaps, an average of 1.01 afferent arteries and 1.05 efferent veins were microanastomosed, and in large flaps, an average of 1.88 afferent arteries and 2.19 efferent veins were anastomosed. In 8 cases where innervated flaps were used for reconstructing the palm of the hand, the average static two-point discrimination was $10\;(8{\sim}15)\;mm$. In 12 cases where tenocutaneous flaps were used, active range of motion at the proximal interphalangeal joint was 60 degrees, 20 degrees at the distal interphalangeal joint, and 75 degrees at the metacarpophalangeal joint. Conclusion: We conclude that the arterialized venous flap is a valuable and effective tool in the reconstruction of hand injuries, and could have a more comprehensive set of indications.

  • PDF

A Foreign Body Found in the Pulmonary Artery of a Traffic Accident Victim with a Chest Injury and Near-amputation of the Upper Extremity - A case report - (흉부 손상과 함께 우상지에 절단에 가까운 열창을 입은 교통 사고 환자에서 발견된 폐동맥 내 이물질 - 1예 보고 -)

  • Choi, Goang-Min;Kim, Heung-Cheol;Cho, Kwang-Yun;Kim, Hyung-Soo
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.536-539
    • /
    • 2008
  • We present a case with a foreign body in the left pulmonary artery, found in a traffic accident victim. A 52-year-old woman sitting in the passenger side of a car had massive bleeding and near complete amputation of her right forearm in addition to multiple rib fractures and a hemopneumothorax. At arrival to the emergency room, the patient had signs of shock; she was anemic, drowsy and hypotensive. A large volume of blood and crystalloid fluids were administered via the left subclavian vein with a rapid infusion device (Level $1^{(R)}$). As the lung contusion improved, a foreign body was noticed in the left lung field on plain x-rays. Pulmonary angiography was performed and revealed a 15 cm foreign body in the left basal segment of the common pulmonary artery. The foreign body was successfully retrieved using vascular forceps via the percutaneous femoral vein approach.

Versatile Applications of Anterolateral Thigh Perforator Flap in the Reconstruction of Upper Extremity Defects: Retrospective Analysis of 119 Cases (수부 및 상지 재건을 위한 전외측 대퇴부 천공지 유리피판의 다양한 이용: 119예의 후향적 분석)

  • Kim, Joo-Yong;Park, Ji-Gang;Lee, Hang-Ho;Lee, Young-Keun;Woo, Sang-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: The perforator flaps have established their role in the reconstruction of various soft tissue defects. For the last five years, we have extensively used anterolateral thigh (ALT) flap for the reconstruction of the complex tissue defects of the hand and upper extremity and report the clinical results and our experiences with the versatile applications of this flap. Materials and Methods: From March 2003 through May 2008, 119 free ALT perforator flaps were transferred for reconstruction of the complex tissue defects of the elbow, forearm, wrist and hand after crushing or degloving injuries as well as severe scar contractures. There were 95 females and 24 males. The mean age of the patients was 37 years and mean size of the flap was 170 $cm^2$. In 20 cases, the flap was vascularized by septocutaneous and in 99 cases by musculocutaneous perforators. Intra-muscular dissection length averaged 3.4 cm. The total length of pedicle averaged 8.4 cm and the average arterial diameter was 0.84 mm. End-to-end arterial anastomosis was performed in 103 cases and end-to-side in 16 cases. Results: Flap survival rate was 98.3%(117/119) and there were 6 cases of partial necrosis. Donor site was closed primarily in 41 cases and skin grafts were applied in 78 cases. Conclusion: The reliability and versatility of ALT flap makes it one of the foremost choices for the reconstruction of complex tissue defects of the upper extremity.

  • PDF

A Study on Relationship between Physical Elements and Tennis/Golf Elbow

  • Choi, Jungmin;Park, Jungwoo;Kim, Hyunseung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.183-196
    • /
    • 2017
  • Objective: The purpose of this research was to assess the agreement between job physical risk factor analysis by ergonomists using ergonomic methods and physical examinations made by occupational physicians on the presence of musculoskeletal disorders of the upper extremities. Background: Ergonomics is the systematic application of principles concerned with the design of devices and working conditions for enhancing human capabilities and optimizing working and living conditions. Proper ergonomic design is necessary to prevent injuries and physical and emotional stress. The major types of ergonomic injuries and incidents are cumulative trauma disorders (CTDs), acute strains, sprains, and system failures. Minimization of use of excessive force and awkward postures can help to prevent such injuries Method: Initial data were collected as part of a larger study by the University of Utah Ergonomics and Safety program field data collection teams and medical data collection teams from the Rocky Mountain Center for Occupational and Environmental Health (RMCOEH). Subjects included 173 male and female workers, 83 at Beehive Clothing (a clothing plant), 74 at Autoliv (a plant making air bags for vehicles), and 16 at Deseret Meat (a meat-processing plant). Posture and effort levels were analyzed using a software program developed at the University of Utah (Utah Ergonomic Analysis Tool). The Ergonomic Epicondylitis Model (EEM) was developed to assess the risk of epicondylitis from observable job physical factors. The model considers five job risk factors: (1) intensity of exertion, (2) forearm rotation, (3) wrist posture, (4) elbow compression, and (5) speed of work. Qualitative ratings of these physical factors were determined during video analysis. Personal variables were also investigated to study their relationship with epicondylitis. Logistic regression models were used to determine the association between risk factors and symptoms of epicondyle pain. Results: Results of this study indicate that gender, smoking status, and BMI do have an effect on the risk of epicondylitis but there is not a statistically significant relationship between EEM and epicondylitis. Conclusion: This research studied the relationship between an Ergonomic Epicondylitis Model (EEM) and the occurrence of epicondylitis. The model was not predictive for epicondylitis. However, it is clear that epicondylitis was associated with some individual risk factors such as smoking status, gender, and BMI. Based on the results, future research may discover risk factors that seem to increase the risk of epicondylitis. Application: Although this research used a combination of questionnaire, ergonomic job analysis, and medical job analysis to specifically verify risk factors related to epicondylitis, there are limitations. This research did not have a very large sample size because only 173 subjects were available for this study. Also, it was conducted in only 3 facilities, a plant making air bags for vehicles, a meat-processing plant, and a clothing plant in Utah. If working conditions in other kinds of facilities are considered, results may improve. Therefore, future research should perform analysis with additional subjects in different kinds of facilities. Repetition and duration of a task were not considered as risk factors in this research. These two factors could be associated with epicondylitis so it could be important to include these factors in future research. Psychosocial data and workplace conditions (e.g., low temperature) were also noted during data collection, and could be used to further study the prevalence of epicondylitis. Univariate analysis methods could be used for each variable of EEM. This research was performed using multivariate analysis. Therefore, it was difficult to recognize the different effect of each variable. Basically, the difference between univariate and multivariate analysis is that univariate analysis deals with one predictor variable at a time, whereas multivariate analysis deals with multiple predictor variables combined in a predetermined manner. The univariate analysis could show how each variable is associated with epicondyle pain. This may allow more appropriate weighting factors to be determined and therefore improve the performance of the EEM.

Clinical Application of Radial Head Prosthesis (요골두 치환술의 임상적 적용)

  • Moon, Jun-Gyu
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.140-145
    • /
    • 2011
  • Purpose: Installing a radial head prosthesis has developed into a reliable procedure to replace the native radial head for treating unreconstructible radial head fracture when this is associated with an unstable elbow or forearm. A variety of implants have been developed and these are now commercially available. This article reviews the literature related to the indications, the available implants and the surgical techniques of radial head replacement arthroplasty. Materials and Methods: The main indication for a metallic radial head prosthesis is a comminuted fracture that is not amenable to reconstruction, and particularly if it is associated with complex elbow injuries. Excision of the radial head should be avoided in the presence of combined injured ligaments or interosseous membrane injury. Three different implants are available in Korea, including the bipolar, press fit monopolar and loose fit monopolar radial head prostheses. A primary technical goal of radial head arthroplasty is the insertion of an implant that closely replicates the native radial head. The major pitfall when using a metallic radial head prosthesis is the insertion of a longer implant, which results in overstuffing of the radiocapitellar joint. Results and Conclusion: Satisfactory clinical results can be anticipated when a radial head prosthesis is used for the correct indications and when a systemic approach is undertaken to ensure proper sizing. For the future studies, we need data regarding the long term outcomes and comparison of the various types of prostheses.

Acute Hydrofluoric Acid Exposure: Our Clinical Experience at Emergency Centers in Two University Teaching Hospitals (2개 대학병원 응급센터에 내원한 급성 불화수소산 노출 환자에 대한 임상적 경험)

  • Han, Kyu-Hong;Yang, Jung-Il;Jo, Seung-Yook;Cho, Yong-Chul;Ryu, Seung;Lee, Jin-Woong;Kim, Seung-Whan;Yoo, In-Sool;You, Yeon-Ho;Park, Jung-Soo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.7 no.2
    • /
    • pp.121-126
    • /
    • 2009
  • Purpose: We investigated the clinical characteristics and demographics of patients who suffered from hydrofluoric acid chemical injury and the mechanism of damage. Methods: We retrospectively reviewed the medical records of patients who were exposed to hydrofluoric acid from March 2004 to March 2009 and who were seen at the emergency centers in two university teaching hospitals. Results: Forty four patients out of 47 patients suffered from chemical burn, while the injuries of the remaining 3 could not be identified by the medical records. A total of 17 hydrofluoric acid chemical injury patients were enrolled during the study period, and their mean age was $29.6{\pm}7.0$. All the patients were accidentally injured by contact with the material and none of them inhaled or ingested the material. Only 6 patients wore appropriate protective equipments and 5 underwent the water irrigation for more than 10 minutes. The most common exposure area was the hand and forearm (70.5%). Less than 1% of all of the patients had their total body surface (TBS) exposed to hydrofluoric acid (mean=0.35%). The mean time interval from calcium gluconate administration to pain relief was $33.6{\pm}8.8$ hours. Conclusion: When exposed to hydrofluoric acid, it is important to wear protective equipment and undergo water irrigation for more than 10 minutes. Pain and skin damage were observed in all the patients. After treatment, we concluded that administration of calcium gluconate and pain killers was successful in relieving pain, and the prognosis was also positive for the admitted and followed up patients when less than 1% of the TBS was exposed.

  • PDF

Ultrasound-Guided Axillary Brachial Plexus Block, Performed by Orthopedic Surgeons (정형외과 의사가 시행한 초음파 유도 액와 상완 신경총 차단술)

  • Kim, Cheol-U;Lee, Chul-Hyung;Yoon, Ja-Yeong;Rhee, Seung-Koo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.513-521
    • /
    • 2018
  • Purpose: The purpose of this study was to assess the effectiveness and complications of an ultrasound-guided axillary brachial plexus block performed by orthopedic surgeons. Materials and Methods: From March to May 2017, an ultrasound-guided axillary brachial plexus block was performed on a total of 103 cases of surgery. A VF13-5 transducer from Siemens Acuson X300 was used. The surgical site was included in the range of the anatomic sensory distribution of the blocked nerve, except for the case where an operation time of more than 2 hours was expected due to multiple injuries and the operation of the upper arm. The procedure was performed by 2 orthopedic surgeons in the same method using 50 ml of solution (20 ml of lidocaine HCl in 2%, 20 ml of ropivacaine in 0.75%, 10 ml of normal saline in 0.9%). The success rate of anesthesia induction during surgery, anesthetic induction time, anatomical range of operation, duration of postoperative analgesia and complications were investigated. Results: The results from the 2 practices were similar. The anesthesia was successful in 100 out of 103 patients (97.1%). In these patients, the average needling time was 5.5 minutes (2.5-13.2 minutes), the average induction time to complete anesthesia was 18.4 minutes (5-40 minutes), and the average duration of postoperative analgesia was 402.8 minutes (141-540 minutes). The post-anesthesia immediate complications were dizziness in 1 case, nausea and vomiting in 4 cases, and peri-oral numbness in 2 cases, but surgery was performed without problems. All these 7 cases with complications recovered on the same day. A total of 3 cases failed with anesthesia, and they were treated by an injection with local anesthesia in the operation room in 2 cases and switched to general anesthesia in 1 case. Conclusion: An ultrasound-guided axillary brachial plexus block, which was performed by orthopedic surgeons allows anesthesia in a brief period and the high success rates of anesthesia for certain surgeries of the elbow and surgeries on forearm, wrist and hand. Therefore, it can reduce the waiting time to the operating room. This technique is a relatively safe procedure and dose selective anesthesia is possible.