• Title/Summary/Keyword: Forced vital capacity test

Search Result 134, Processing Time 0.028 seconds

Effects of Underwater Treadmill Gait Training on Gait, Balance, and Pulmonary Function in Stroke Patients

  • Yang, Ho-june;Choi, Jong-duk
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.34-43
    • /
    • 2015
  • The purpose of this study was to compare the effects of underwater treadmill gait training (UTGT) and overground treadmill gait training (OTGT) on the gait, balance ability and pulmonary function of stroke patients. Twenty subjects were recruited for this study. The subjects were randomly assigned to two groups: UTGT ($n_1$=10) and OTGT ($n_2$=10). The 10 m walk test (10 MWT), Berg Balance Scale, Timed Up and Go (TUG) test, center of pressure, pulmonary function of forced vital capacity (FVC), forced expiratory volume after 1 sec (FEV1) and FEV1/FVC were measured before and after 4 weeks of training. Both groups undertook the gait training for 30 min a day, 3 times a week, for 4 weeks, and rating of perceived exertion of the groups were measured and compared. All the studied variables were significantly improved in both groups (p<.05) at the end of the study, except in the FEV1 of OTGT (p>.05). There was significant between-group difference in all of the variables, except in the 10 MWT (p>.05). These findings suggest that UTGT is more effective than OTGT in improving the balance and pulmonary functions of stroke patients.

Effects of Breathing Exercises Using Virtual Reality and Schroth Breathing Exercises on the Lung Function of Adults in Their 20s

  • Byung-Kon Kim;Wook-Jin Lee
    • The Journal of Korean Physical Therapy
    • /
    • v.36 no.2
    • /
    • pp.67-70
    • /
    • 2024
  • Purpose: This study investigated the effect of virtual reality and Schroth breathing exercises on the lung function characteristics of normal adults in their 20s. Methods: The subjects were randomly divided into groups with ten people each in the experimental groups, namely the virtual reality breathing exercise group (BBEG) and the Schroth breathing exercise group (SBEG), and the control group. The experimental groups performed each breathing exercise for 4 weeks. Subsequently, pulmonary function test indicators such as the forced vital capacity (FVC) and the forced expiratory volume (FEV1) were measured. Results: In the within-group comparison of the subjects before and after the exercises, there was a significant difference in the FVC and FEV1 (p<0.05), but there was no significant difference in FEV1/FVC. The result of the difference test between groups showed that there was a significant difference in FEV1/FVC after exercise (p<0.05). However, there were no significant differences in the remaining items (p>0.05). Conclusion: Improvement in lung function was seen in both exercise groups, and the changes in FEV1/FVC indicated significant improvement in the lung function of the experimental groups compared to the control group.

The Effects of Scapula and Pelvis Symmetrical Reciprocal Pattern of PNF Concept on Respiratory Function and Quality of Life in the Elderly (PNF의 어깨뼈 골반 대칭 상호 패턴이 노인의 호흡기능과 삶의 질에 미치는 효과)

  • Byoung-Hyoun Moon;Ji-Won Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.55-63
    • /
    • 2024
  • Purpose : The purpose of this study is to determine the effects of scapula and pelvis symmetrical reciprocal pattern exercise of PNF concept on respiratory function and quality of life in elderly subjects. Methods : Nineteen elderly subjects with healthy were recruited. Subjects performed scapula and pelvis symmetrical reciprocal pattern exercise of PNF concept. Exercise was appied 30 minutes three times per week for four weeks. The respiratory function and quality of life (QOL) test three times (before, two weeks, and four weeks). Respiratory function includes forced vital capacity (FVC), forced expiratory volume at one second (FEV1), Peak Expiratory Flow (PEF) and chest cage expansion test (CCET). The QOL test was measured Korean WHOQOL-BRIEF. The analysis method was analyzed through the one-way ANOVA repeated methods, and the statistical significance is α=.05. It was analyzed through the post test Bonferroni test. Results : After the 4 week scapula and pelvis symmetrical reciprocal pattern exercise of PNF concept showed statistically significant differences in the respiratory function (FVC, FEV1, PEF, and CCET), and QOL (p<.05). As a result of the post-hoc test, FVC showed a significant increase in the mid test and post test compared to the pre test (p<.05), FEV1 showed a significant increase in the post test compared to the pre test (p<.05). PEF showed a significant increase in all pre-test, mid-test, and post-test sections (p<.05), CCET showed a significant increase in all pre-test, mid-test, and post-test sections (p<.05). QOL showed a significant increase in all pre-test, mid-test, and post-test sections (p<.05). Conclusion : In this study, the scapula and pelvis symmetrical reciprocal pattern exercise of PNF concept improved respiratory function and QOL. The findings suggest that this intervention could be beneficial in improving respiratory function and QOL in the elderly.

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF

Annual Changes of Lung Function in Retired Workers Exposed to Inorganic Dusts (과거 무기분진에 노출된 이직근로자들의 연간 폐기능 변화)

  • Lee, Joung-Oh;Choi, Byung-Soon;Lee, Jong-Seong;Jeong, Jee-Yeon;Lee, Hong-Ki
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.5
    • /
    • pp.341-348
    • /
    • 2011
  • Background: The aim of this study was to investigate annual changes in pulmonary function in workers who were exposed to inorganic dust. Methods: The subjects were 2,922 male patients who had been diagnosed with pneumoconiosis more than twice during 6 years from 2005 to 2010. Results: Of the 2,922 cases, forced vital capacity (FVC) decreased by 54 mL in 1 year. In contrast, the annual change of forced expiratory volume in one second ($FEV_1$) decreased by 56 mL. Conclusion: This is the first study that has investigated the annual change in pulmonary function in workers exposed to inorganic dust. The results will help estimate the pulmonary condition of patients who are unable to perform a pulmonary function test due to age or a disorder.

Relationship Between Trunk Control and Respiratory Function in Stroke Patients (뇌졸중 환자의 체간조절과 호흡기능의 관계)

  • Lee, Kyeong-Jin;Kim, Nan-Soo
    • Archives of Orthopedic and Sports Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.25-32
    • /
    • 2018
  • Purpose: This study aimed to investigate the relationship between trunk control and pulmonary function and respiratory muscle strength in stroke patients. Methods: This study included 30 patients who had been clinically diagnosed with strokes, and trunk control abilities were measured using the trunk impairment scale (TIS). The subjects were classified into a group with high trunk control ability (TIS score ${\geq}20$) and a group with low trunk control ability (TIS score < 20). The patients' forced vital capacity (FVC), forced expiratory volume in one second (FEV1), peak expiratory flow (PEF), maximal inspiratory pressure (MIP), and maximal expiratory pressure (MEP) were measured. To compare the pulmonary function and respiratory muscle strength between the two groups, the measurement data were analyzed using an independent T-test, and the relationship between TIS and respiratory function was analyzed using a Pearson correlation. Results: The high trunk control ability group had significantly higher pulmonary function and respiratory muscle strength than the low trunk control ability group. Significant positive correlations were found between trunk control and FVC, FEV1, PEF, MIP, and MEP. Conclusions: This study demonstrated that trunk control affects pulmonary function and respiratory muscle strength in stroke patients.

The Effects of Respiratory Muscle Strengthening Training on Pulmonary Function and Gait Ability in Subacute Stroke Patients (호흡근 강화 훈련이 아급성 뇌졸중 환자의 폐기능과 보행 능력에 미치는 영향)

  • Kim, Jin-Seok;Shin, Won-Seob
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.4
    • /
    • pp.489-496
    • /
    • 2013
  • PURPOSE: The aim of this study was to investigate the effect of respiratory muscle strengthening training on pulmonary function and gait ability in patients with subacute stroke. METHODS: Eighteen inpatients with subacute stroke were recruited for this study. The subjects were randomized into two group. All study groups participated in a conventional stroke rehabilitation intervention 30minutes a day 5 times a week for 4 weeks. For subjects from the experimental group, respiratory muscle strengthening training was performed: 30minutes a day 3 times a week for 4 weeks. Outcomes such as the pulmonary function(Forced Vital Capacity, Forced Expiratory Volume in one second, Maximal Voluntary Ventilation) and gait ability(10m walk test, 6 minute walk test) were measured before and after training. RESULT: There were significant differences of pulmonary function(FVC, FEV1 and MVV) and gait ability(10m walk test, 6minute walk test) between pre and post in the experimental group. In comparison of two group, experimental group was significant different pulmonary function(FVC, FEV1, MVV) and gait ability(6minute walk test) than control group. but, There was no significant difference of the gait ability(10m walk test). CONCLUSION: This study showed experimental group can be used to improve pulmonary function and gait ability than control group. These findings suggest that the respiratory muscle strengthening training effect on pulmonary function and gait ability for rehabilitation in patients with subacute stroke.

Reliability of Portable Spirometry Performed in the Korea National Health and Nutrition Examination Survey Compared to Conventional Spirometry

  • Park, Hye Jung;Rhee, Chin Kook;Yoo, Kwang Ha;Park, Yong Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.274-281
    • /
    • 2021
  • Background: The Korea National Health and Nutrition Examination Survey (KNHANES) is a well-designed survey to collect national data, which many researchers have used for their studies. In KNHANES, although portable spirometry was used, its reliability has not been verified. Methods: We prospectively enrolled 58 participants from four Korean institutions. The participants were classified into normal pattern, obstructive pattern, and restrictive pattern groups according to their previous spirometry results. Lung function was estimated by conventional spirometry and portable spirometry, and the results were compared. Results: The intraclass correlation coefficients of forced vital capacity (FVC) (coefficient, 9.993; 95% confidence interval [CI], 0.988-0.996), forced expiratory volume in 1 second (FEV1) (coefficient, 0.997; 95% CI, 0.995-0.998), FEV1/FVC ratio (coefficient, 0.995; 95% CI, 0.992-0.997), and forced expiratory flow at 25-75% (FEF25-75%; coefficient, 0.991; 95% CI, 0.984-0.994) were excellent (all p<0.001). In the subgroup analysis, the results of the three parameters were similar in all groups. In the overall and subgroup analyses, Pearson's correlation of all the parameters was also excellent in the total (coefficient, 0.986-0.994; p<0.001) and subgroup analyses (coefficient, 0.915-0.995; p<0.001). In the paired t-test, FVC, FEV1/FVC, and FEF25-75% estimated by the two instruments were statistically different. However, FEV1 was not significantly different. Conclusion: Lung function estimated by portable spirometry was well-correlated with that estimated by conventional spirometry. Although the values had minimal differences between them, we suggest that the spirometry results from the KNHANES are reliable.

The Effects of McKenzie Exercise on Forward Head Posture and Respiratory Function

  • Kim, SeYoon;Jung, JuHyeon;Kim, NanSoo
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.6
    • /
    • pp.351-357
    • /
    • 2019
  • Purpose: This study sought to investigate the effects of the McKenzie exercise program on forward head posture and respiratory function. Methods: Thirty adult men and women with forward head posture, aged 20-29 years, were randomly assigned to the experimental group (N=15) or the control group (N=15). Subjects in the experimental group performed the McKenzie exercises three times a week for four weeks, while subjects in the control group did not receive any intervention. Craniovertebral angle (CVA) was measured to quantify forward head posture, and forced vital capacity (FVC), FVC % predicted, forced expiratory volume at one second (FEV1), and FEV1 % predicted were measured to determine changes in respiratory function. The Mann-Whitney U-test was used to analyze pre-test differences in forward head posture and respiratory function between the two groups, and the Wilcoxon signed-rank test was used to analyze differences in forward head posture and respiratory function within the groups before and after intervention. The significance level (α) was set to 0.05. Results: A comparison of pre- and post-test measures showed that CVA significantly increased in the experimental group (p=0.001) denoting postural improvement, whereas no significant difference was found in the control group (p=0.053). All respiratory measures, i.e.,FVC, FVC %pred, FEV1, and FEV1 %pred, were significantly improved in the experimental group, whereas there were no significant differences in the control group. Conclusions: McKenzie exercise can be effective in improving forward head posture and respiratory function.

Goodness-of-Fits of the Spirometric Reference Values for Koreans and USA Caucasians to Spirometry Data from Residents of a Region within Chungbuk Province

  • Eom, Sang-Yong;Moon, Sun-In;Yim, Dong-Hyuk;Lee, Chul-Ho;Kim, Guen-Bae;Kim, Yong-Dae;Kang, Jong-Won;Choe, Kang-Hyeon;Kim, Sung-Jin;Choi, Byung-Sun;Yu, Seung-Do;Chang, Soung-Hoon;Park, Jung-Duck;Kim, Heon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.3
    • /
    • pp.302-309
    • /
    • 2012
  • Background: Korean regression models for spirometric reference values are different from those of Americans. Using spirometry results of Korean adults, goodness-of-fits of the Korean and the USA Caucasian regression models for forced vital capacity (FVC) and forced expiratory volume in one second ($FEV_1$) were compared. Methods: The number of study participants was 2,360 (1,124 males and 1,236 females). Spirometry was performed under the guidelines of the American Thoracic Society and the European Respiratory Society. After excluding unsuitable participants, spirometric data for 729 individuals (105 males and 624 females) was included in the statistical analysis. The estimated FVC and $FEV_1$ values were compared with those measured. Goodness-of-fits for Korean and USA Caucasian models were compared using an F-test. Results: In males, the expected values of FVC and $FEV_1$ using the Korean model were 12.5% and 5.7% greater than those measured, respectively. The corresponding values for the USA Caucasian model were 3.5% and 0.6%. In females, the difference in FVC and $FEV_1$ were 13.5% and 7.7% for the Korean model, and 6.3% and 0.4% for the USA model, respectively. Goodness-of-fit for the Korean model regarding FVC was not good to the study population, but the Korean regression model for $FEV_1$, and the USA Caucasian models for FVC and $FEV_1$ showed good fits to the measured data. Conclusion: These results suggest that the USA Caucasian model correlates better to the measured data than the Korean model. Using reference values derived from the Korean model can lead to an overestimation regarding the prevalence of abnormal lung function.