• 제목/요약/키워드: Force-Torque Sensor

검색결과 132건 처리시간 0.031초

분리층의 상대 변위를 이용한 고분자 미끄럼 촉각 센서 개발 (Development of Polymer Slip Tactile Sensor Using Relative Displacement of Separation Layer)

  • 김성준;최재영;문형필;최혁렬;구자춘
    • 로봇학회논문지
    • /
    • 제11권2호
    • /
    • pp.100-107
    • /
    • 2016
  • To realize a robot hand interacting like a human hand, there are many tactile sensors sensing normal force, shear force, torque, shape, roughness and temperature. This sensing signal is essential to manipulate object accurately with robot hand. In particular, slip sensors make manipulation more accurate and breakless to object. Up to now several slip sensors were developed and applied to robot hand. Many of them used complicate algorithm and signal processing with vibration data. In this paper, we developed novel principle slip sensor using separation layer. These two layers are moved from each other when slip occur. Developed sensor can sense slip signal by measuring this relative displacement between two layers. Also our principle makes slip signal decoupled from normal force and shear force without other sensors. The sensor was fabricated using the NBR(acrylo-nitrile butadiene rubber) and the Ecoflex as substrate and a paper as dielectric. To verify our sensor, slip experiment and normal force decoupling test were conducted.

Analysis of Noise Effects in Data Acquisition of Multi-Axis Force/Torque Sensors

  • Kang, Chul-Goo;Kim, Yong-Chan;Park, Chol-Ho;Nam, Hyun-Do
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1254-1258
    • /
    • 2003
  • One of the major factors that effect sensor performance is analog noise that added in a sensor signal such as voltage. In multi-axis force sensors, error sources may be classified mainly in two groups. One is structural error due to inaccuracy of sensor body. The other error source is noise signals existing in the sensed information. This paper presents a brief review about the principle of multi-axis force sensors, and then proposes a method that can reduce the effect of noise signal to sensor performance. The method is to convert analog voltage signal to digital numbers near sensor body and then to read these digital signals and conduct signal processing in the computer. By this way, we can eliminate a bad effect of electromagnetic wave emitted from computer and of 60 Hz noise emitted from AC source. The proposed method is investigated through experimental demonstration. The experimental results show that it improves S/N ratio of the sensor about 40 times in our experimental setup.

  • PDF

로봇손을 이용한 미지 물체의 능동적 형상탐사에 관한 연구 (Active shape exploration of an unknown object by using robot hand)

  • 김진호;오상록;최혁렬
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.768-771
    • /
    • 1997
  • Geometric probing addresses the problem of determining geometric aspects of a structure from the mathematics and results of a physical measuring device such as a probe. This paper presents a new algorithm to recognize the shape of an unknown object by using a robot hand with a force and torque sensor. The new algorithm is called S.E.P.(Shape Exploration Procedure) which finds the global shape of an unknown object. The proposed method is composed of three major parts, finding contact informations such as contact point, calculation of shape information such as curvature, and expression of global shape from these informations. Comparing with the conventional approaches, the advantages of the proposed method are explained and verified by conducting experiments with a 3-dof SCARA robot.

  • PDF

로봇손의 능동접촉에 의한 3차원 볼록한 물체의 곡률탐사 (Exploration of Curvature of Three Dimensional Convex Object by Active Touch of Robot Hand)

  • 최혁렬;김진호;오상록
    • 한국정밀공학회지
    • /
    • 제16권2호통권95호
    • /
    • pp.130-137
    • /
    • 1999
  • In this paper we propose a method of determining the local curvature of a three dimensional convex object using the force and torque information obtained from the active touch of a robot hand. A technique for estimating two dimensional curvature of a convex object are introduced and the way of computing the three dimensional curvature from the two dimensional vurvatures is presented. Also, we develop an experimental system consisting of a finger and verify the effectiveness of the proposed method experimentally.

  • PDF

저가형 3D프린팅 2축 압력 센서 개발 (Development of Low-cost 3D Printing Bi-axial Pressure Sensor)

  • 최헌수;여준성;성지훈;최현진
    • 로봇학회논문지
    • /
    • 제17권2호
    • /
    • pp.152-158
    • /
    • 2022
  • As various mobile robots and manipulator robots have been commercialized, robots that can be used by individuals in their daily life have begun to appear. With the development of robots that support daily life, the interaction between robots and humans is becoming more important. Manipulator robots that support daily life must perform tasks such as pressing buttons or picking up objects safely. In many cases, this requires expensive multi-axis force/torque sensors to measure the interaction. In this study, we introduce a low-cost two-axis pressure sensor that can be applied to manipulators for education or research. The proposed system used three force sensitive resistor (FSR) sensors and the structure was fabricated by 3D printing. An experimental device using a load cell was constructed to measure the biaxial pressure. The manufactured prototype was able to distinguish the +-x-axis and the +-y-axis pressures.

힘 제어 알고리즘을 이용한 응용 S/W팩키지의 개발 (The development of application S/W packages using force control algorithm)

  • 정재욱;고명삼;이범희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.244-249
    • /
    • 1989
  • For the robot manipulator in performing precision tasks, it is indispensable that the robot utilize the various sensors for intelligence. In this paper, the hybrid position/force control method is implemented with a force/torque sensor, two personal computers, and a PUMA 560 manipulator. Two application S/W packages for edge following and peg-in-hole tasks are developed by the proposed force control algorithm. The related experimental results are then presented and discussed,

  • PDF

BLDC 모터 기반 동력 의족의 구성과 토크 추정을 활용한 유각기의 임피던스 제어 (The Structure of a Powered Knee Prosthesis based on a BLDC Motor and Impedance Control using Torque Estimation on Free Swing)

  • 경기영;김진걸;이영삼
    • 제어로봇시스템학회논문지
    • /
    • 제21권5호
    • /
    • pp.407-412
    • /
    • 2015
  • This paper presents the design of a lab-built powered knee prosthesis based on a BLDC motor, a sensored impedance control using a force sensor, and a sensorless impedance control through torque estimation. Firstly, we describe the structure of the lab-built powered knee prosthesis and its limitations. Secondly, we decompose the gait cycle into five stages and apply the position-based impedance control for the powered knee prosthesis. Thirdly, we perform an experiment for the torque estimation and the sensorless impedance control of the prosthesis. The experimental results show that we can use the torque estimation to control the low impedance during the swing phase, although the estimated torque data has a delay compared with the measured torque by a load cell.

족관절 보조기를 착용한 고령자의 족관절 족저굴곡 토크 보조특성 분석 (Analysis of the Assist Characteristics for Torque of the Ankle Plantarflexion in Elderly Adults Wearing the Ankle-Foot Orthosis)

  • 김경;강승록;박용군;정구영;권대규
    • 로봇학회논문지
    • /
    • 제5권1호
    • /
    • pp.48-54
    • /
    • 2010
  • Ankle-foot orthosis with a pneumatic rubber actuator, which is intended for the assistance and the enhancement of ankle muscular activities was developed. In this study, the effectiveness of the system was investigated during plantarflexion motion of ankle joint. To find a effectiveness of the system, the subjects performed maximal voluntary isokinetic plantarflexion contraction on a Biodex-dynamometer. Plantarfexion torque of the ankle joint is assisted by subject's soleus muscle that is generated when ankle joint do plantarflexion motion. We used the muscular stiffness signal of a soleus muscle for feedback control of ankle-foot orthosis as physiological signal. For measurement of this signal, we made the muscular stiffness force sensor. We compared a muscular stiffness force of a soleus muscle between with feedback control and without it and a maximal plantarflexion torque between not wearing a ankle-foot orthosis, without feedback control wearing it and with feedback control wearing it in each ten elderly adults. The experimental result showed that a muscular stiffness force of a soleus muscle with feedback control was reduced and plantarflexion torque of an ankle joint only wearing ankle-foot orthosis was reduced but a plantarflexion torque with feedback control was increased. The amount of a increasing with feedback control is more higher than the amount of a decreasing only wearing it. Therefore, we confirmed the effectiveness of the developed ankle-foot orthosis with feedback control.

직렬 탄성 액츄에이터 기반의 로봇 손가락의 힘 제어 (Force Control of Robot Fingers using Series Elastic Actuators)

  • 이승엽;김병상;송재복;채수원
    • 제어로봇시스템학회논문지
    • /
    • 제18권10호
    • /
    • pp.964-969
    • /
    • 2012
  • Robot hands capable of grasping or handling various objects are important for service robots to effectively aid humans. In particular, controlling a contact force and providing a compliant motion are essential when the hand is in contact with objects. Many dexterous robot hands equipped with force/torque sensors have been developed to perform force control, but they suffer from the complexity of control and high cost. In this paper, a low-cost robot hand based on SEA (Series Elastic Actuator), which is composed of compression spring, stretch sensor, and wire, is proposed. The grasping force can be estimated by measuring the compression length of spring, which would allow the hand to perform force control. A series of experimentations are carried out to verify the performance of force control of the proposed robot hand, and it is shown that it can successfully control the contact force without any additional force/torque sensors.

등속운동을 이용한 관절계 역학적 특성치 정량화 방법의 유용성 평가 (Evaluation of the Identification method of Joint Mechanical Properties Using Isokinetic Movement)

  • 이창한;허지운;김철승;엄광문
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1190-1193
    • /
    • 2004
  • The purpose of this study is to evaluate the possibility of identifying joint damping property through commercially available isokinetic ergometer (BIODEX). The proposed method is to estimate the damping torque of the knee joint from the difference between the external joint torque for maintaining isokinetic movement and the gravity torque of the lower leg. The damping torque was estimated at various joint angular velocities, from which the damping property would be derived. Measurement setup was composed of the BIODEX system with an external force sensor and Labview system. Matlab was used in the analysis of the damping property. The experimental result showed that the small variation in angular velocity due to acceleration and deceleration of the crank arm resulted in greater change of inertial torque than the damping torque, so that the estimation of damping property from the isokinetic movement is difficult.

  • PDF