• 제목/요약/키워드: Footwear measuring system

검색결과 6건 처리시간 0.021초

Studies on Clothing Comfort Evaluation of Footwear by Measuring Psychophysiological Response

  • Hosoya, Satoshi;Kamijo, masayoshi;Takatera, Masayuki;Sadoyama, Tsugutake
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2002년도 춘계학술대회 논문집
    • /
    • pp.186-189
    • /
    • 2002
  • The footwear such as socks and shoes is the clothing which are necessary to our life. In this study, clothing comfort of the footwear was carried out by physiological responses and subjective evaluation. As a result, the effect to walking comfort by the height of a heel in female shoes became clear. Then suitability evaluation system of shoes was proposed from the measuring results. On the other hands, the clothing comfort of the hosiery was evaluated from ECG analysis. By this analysis, it became clear that the factor which influences the clothing comfort of the hosiery was the clothes pressure in the hosiery. In the future, plane shape of the foot and solid shape must be considered in order to design the hosiery.

  • PDF

레이저 센서를 이용한 신발 내측 측정장치 개발 (Development of an Internal Measurement System for the Footwear using Laser Sensor)

  • 이지용;김민주;이승수;박재덕;전언찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.281-284
    • /
    • 2004
  • This paper presents studies on the development of an internal measurement system for the footwear using laser sensor. The measurement system gains to the height of the profile at internal footwear. It accomplishes the 3-axises control which uses ball screws, L-M guides and stepping motors. It is used a laser sensor at the measurement of the distance, and Labview is used for the control and the measurement. We can get the profile through reverse engineering for the LAST. The data of profile is fixed a heigh of the LAST. Then, we try to verify as compare the profile with one which is collected by Internal measurement system..

  • PDF

신발의 굽힘강성 측정 장비의 개발 (Development of Measurement Device for Bending Stiffness of Footwear)

  • 이종년
    • 한국산학기술학회논문지
    • /
    • 제12권3호
    • /
    • pp.1078-1084
    • /
    • 2011
  • 스포츠화의 설계에서 신발 앞축 부분의 굽힘강성은 매우 중요한 설계인자이지만, 측정하기가 어렵다. 본 논문은 이러한 굽힘강성을 측정하는 장비를 소개한다. 장비는 알루미늄 프레임 구조와 AC 모터, 2개의 로드셀, 엔코더와 제어용 하드웨어로 구성되어있으며, 신발의 굽힘 모멘트를 측정하는 메카니즘을 소개하였다. 유용성을 입증하기 위하여, 신발의 소재와 디자인이 굽힘강성에 미치는 영향을 관찰하는데 사용되어 졌다. 실험을 위하여 신발 중창소재의 경도와 두께를 달리하여 완성신발 시편을 제작하였다. 이들 시편으로 굽힘실험을 수행하고, 최소자승법을 사용하여 굽힘강성을 구하였다. 실험결과 PU 중창으로 만든 신발이 PH 중창으로 만든 신발보다 굽힘강성이 높았으며, 중창의 두께가 중창의 경도보다 굽힘강성에 미치는 영향이 크다는 것을 알아낼 수 있었다. 따라서, 이러한 실험결과를 바탕으로, 본 측정장비는 유용한 실험결과를 도출할 수 있었으며, 이 장비를 통하여 측정된 신발의 굽힘강성은 신발 설계의 유용한 설계인자로 활용될 수 있다고 사료된다.

발계측 자료에 기초한 신골 할출 시스템의 검증에 관한 연구 (A Study on Verification of Shoe Last Grading System Based on Foot Measuring Data)

  • 박해수
    • 대한인간공학회지
    • /
    • 제26권1호
    • /
    • pp.71-77
    • /
    • 2007
  • Shoe's size and shape are determined by the last that takes shape of foot because last is the mold of shoe in development and manufacturing process. Then adaptation between foot and shoe is dependent on the last. In mass shoe production, model size is developed in the first place, other sized lasts are made through the grading process based on model size. The most important factor in grading system is grading deviation that must be same amount induced from foot measuring database. At present, most of the last manufacturing companies in korea using 260mm as a standard foot model size. When length grading deviation is 5mm, the ball girth grading deviation is 3.7mm and the ball width grading deviation is 1.2mm. I verified existing grading system by comparing grading results with foot measuring data. Also, I proposed reasonable grading deviation and application method of grading system. From the analysis of foot measuring database, reasonable grading deviations are 1.22mm in ball width and 0.84mm in ankle height in case of length grading deviation is 5mm. I confirmed that the current grading system is very accurate. When we grade last from 230mm to 290mm by current grading system based on model size 260mm, there is grading error over 1mm in the front outside area of foot. This error level of 1mm is no problem in normal walking shoe's last, but it induces adaptation problems in sports and special purposed shoe's last. Therefore using of three standard model size is recommended in grading men's last for reducing grading deviation error under the level of 1mm. It is specifically described as 235mm in 225-245mm, 260mm in 250-270mm, 285mm in 275-295mm. According to the above recommended grading system, it is enough to measure only three foot sizes in case of foot measuring project for men's last development.

Application of Equivalent Walking Loads for Efficient Analysis of Floor Vibration Induced by Walking

  • 김기철;김재열
    • 한국공간구조학회논문집
    • /
    • 제4권4호
    • /
    • pp.65-76
    • /
    • 2004
  • Walking loads are usually considered as nodal loads in the finite element vibration analysis of structures subjected to walking loads. Since most of the walking loads act on elements not nodes, the walking loads applied on the elements should be converted to the equivalent nodal walking loads. This paper begins with measuring walking loads by using a force plate equipped with load cells and investigates the characteristics of the walking loads with various walking rates. It is found that the walking loads are more affected by walking rates than other parameters such as pedestrian weight, type of footwear, surface condition of floor etc. The measured walking loads are used as input loads for a finite element model of walking induced vibration. Finally, this paper proposes the equivalent nodal walking loads that are converted from the walking loads acting on elements based on finite element shape functions. And the proposed equivalent walking loads are proved to be applicable for efficient analysis of floor vibration induced by walking loads.

  • PDF

화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발 (Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment)

  • 가동하
    • 한국군사과학기술학회지
    • /
    • 제23권3호
    • /
    • pp.294-301
    • /
    • 2020
  • Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.