• Title/Summary/Keyword: Foot-plate

Search Result 138, Processing Time 0.023 seconds

The Changes of Plantar Foot Pressure by External Loads during Walking in Flatfoot (보행 시 편평족에서 외적 무게 부하에 따른 족저압의 변화)

  • Chang, Jong-Sung;Park, Ji-Won;Kim, Chung-Sun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.4
    • /
    • pp.543-549
    • /
    • 2010
  • Purpose : The study was designed to investigate the changes of plantar foot pressure by different loads during walking in flatfoot. Methods : Fifteen subjects with flatfoot were recruited along with their written informed consent. They were asked to walk on plate at a self-selected and comfortable speed with loads of 0, 5, 10, and 15kg. Three walking trials were obtained and then averaged for data analysis. Foot pressure were measured from RS-Scan system (RS-Scan system, RS scan Ltd., German) and contact area, maximum force were analyzed. Results : There were significant increases on midfoot and decreases on forefoot in contact area. And there were significant increases in maximum force of foot pressure of 2nd metatarsal bone and midfoot. Conclusion : These findings revealed that flatfoot increases risk factors of metatarsal bone with different loads. Therefore, patients of flatfoot must be careful during walking with loads or activities of daily living.

Freiberg's Disease and Metatarsophalangeal Joint Instability (프라이버그병과 중족지 관절 불안정)

  • Young, Kiwon;Kim, Jinsu;Joh, Joowon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.1
    • /
    • pp.11-16
    • /
    • 2013
  • Freiberg's disease is a osteochondrosis of a metatarsal head that is recognized as primarily a disorder of the second metatarsal. It is seen more often in girls. Pain and limitation of motion of the affected joint is the predominant clincal feature. The radiographic appearance demonstrates from osteosclerosis in the early stage to osteolysis with collapse in the later stage. Conservative therapy may take the form of rest, a stiff shoe, and even a cast support to decrease the stress across the joint. Surgical intervention may also be of benefit. Surgery have been attempted either to modify the diseae process or to salvage the situation once the metatarsophalangeal joint develops degenerative changes. Metatarsophalangeal joint instability is common cause of forefoot pain that can develop in association with a traumatic episode and inflamatory tissue disorders as well as neighboring toe deformities. The second ray is by far the most frequently involved. The diagnosis can be made by clinical observation and physical examination including drawer test. Many surgical procedures have beem recommended when conservative treatment has failed. Procedures described range from soft tissue releases and tendon trasfer to the direct plantar plate repair combined with a Weil osteotomy.

The Effects of on CTA and Q-Angle with the Different Position of the Foot in the Standing Status (기립자세에서 발의 변화가 슬개대퇴골각과 종경골각에 미치는 영향)

  • Bae Sung-Soo;Lee Sang-Yong
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.3
    • /
    • pp.203-225
    • /
    • 2002
  • An excessive Q-angle has been implicated in the development of knee injuries by altering the lower-extremity locomotion kinematics. The purpose of this study was performed to examine the correlation between the Q-angle and the CTA during pronation and supination of the foot in the standing status. The participants of this examination were 60 adult(30 men and 30 women) who had no orthopaedic and neurological impairment, aged between 20 and 40years. The foot tilt(FT1)is made of acrylic plate and the slope of the surface is altered as $0^{\circ}$ pronation$(10^{\circ},\;20^{\circ},\;30^{\circ})$ and supination $(10^{\circ},\;20^{\circ},\;30^{\circ})$. The results were as follows : 1. The result about the Q-angle and the CTA by comparing pronation and supination of the foot There was statistical significance difference in the left /right Q-angle and the left/right CTA with pronation and supination of the foot(P<0.05). 2. The result about correlation in the left /right lower-extremity There were positive correlation between the right Q-angle and the right CTA and negative correlation except the supination$(30^{\circ})$ between the left Q-angle and the left CTA.

  • PDF

A Study of Structural Analysis Simulation for Squat Exercise Foot Plate (스쿼트운동장치의 풋플레이트 구조해석에 관한 연구)

  • Jung, Byung-Geun;Kim, Ji-won;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.365-372
    • /
    • 2017
  • Squat exercise is one of the important free weight exercises that can safely and effectively expect the athletic performance by establishing the rationale. Therefore, it is necessary to study the side effects caused by incorrect exercise, scientific countermeasures and to develop a exercise estimation model. It is effective and accurate to use a variety of assistive devices to calibrate athletic posture. The issues of the structural analysis for designing a foot plate for squat exercise is to model the behavior by the dynamic behavior. It should be consider that the center of gravity of each segmented body is different when the maximum load is applied. It is applied to complete system design through simulation method with kinematic dynamic, ground reaction force and load analysis for the free weight exercise equipment, VR device, and safety foot plate. In this paper, the authors propose the design method for the vertical load distribution applied in the design of the foot plate used for the squat exercise mechanism, and based on these results, design make the more safe and reliable free weight exercise equipment system.

Clinical Features of Distal Tibial Fractures and Treatment Results of Minimally Invasive Plate Osteosynthesis (원위 경골 골절의 임상양상 및 최소 침습적 금속판 고정술의 결과)

  • Kim, Weon-Yoo;Ji, Jong-Hun;Kwon, Oh-Soo;Park, Sang-Eun;Kim, Young-Yul;Kil, Ho-Jin;Jeong, Jae-Jung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.2
    • /
    • pp.94-100
    • /
    • 2012
  • Purpose: The purpose of this study is to analyze the clinical features of distal tibia fractures and to evaluate the treatment outcomes of minimally invasive plate osteosynthesis (MIPO). Materials and Methods: From January 2004 to December 2009, 84 cases of 81 patients treated with plate fixation for distal tibia fracture were enrolled in this retrospective review. We investigated age, sex, injury mechanism, fracture patterns, and complications, and the clinical features were analyzed. To evaluate the treatment outcomes of MIPO, we divided into two groups. MIPO group consisted of 55 patients were treated with MIPO technique and conventional group consisted of 18 patients were treated with open reduction and internal fixation with conventional anterolateral plating. The results were compared between two groups by assessing bony union time, operation time, amount of blood loss, range of ankle motion, clinical score by American Orthopaedic Foot and Ankle Society (AOFAS) score, and post-operative complications. Results: The mean age of 81 patients with distal tibia fracture was 54.8 years. According to AO classification, A1:2:3 were 16, 20, 16 patients, B1:2:3 were 2, 8, 7, C1:2:3 were 1, 3, 11 patients. According to injury mechanism, slip down injury was patients, traffic accident was 26, fall from height injury was 14 patients respectively. The type A fractures were lower energy trauma and more older patients. The type C fractures were higher energy trauma and younger patients. MIPO group was better than conventional group in operative time, blood loss, bony union time, and ankle joint motion. In complications, MIPO group showed no nonunion and infection, one malunion, one skin necrosis, nine skin irritations, and one screw breakage. Conventional group showed two nonunion, four infections, two skin necrosis, and one metal failure. Conclusion: Distal tibial fractures caused by low energy trauma were on the increase. Minimal invasive plate osteosynthesis was shorter bony union time and operation time, less blood loss, and larger ankle motions than conventional open reduction and plate fixation.

Arthrodesis of the First metatarsophalangeal joint for Rheumatoid arthritis, using a lag screw and dorsal plate (류마토이드 관절염 환자의 족무지 외반증에 대한 제 1 중족 족지 관절 고정술 -지연 나사못과 배부 금속판을 이용한 치험-)

  • Sung, Il-Hoon;Lee, Hyung-Sang;Whang, Kuhn-Sung;Park, Kee-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.2
    • /
    • pp.142-148
    • /
    • 2001
  • Purpose: To investigate the short term result of the first metatarsophalangeal arthrodesis for treating the hallux valgus deformity of rheumatoid arthritis, using a lag screw and dorsal mini-plate. Materials and Methods: From December 1999 to September 2001, The first metatarsophalangeal arthrodesis of 14 cases (9 patients) was underwent, using a lag screw and dorsal mini-plate. The follow-up period was averaged in 14.6 months. The subjective findings with respect to pain, functional aspect of ability to stand and walk, and to shoe-wearing were evaluated. The objective findings, such as the gross alignment and the radiological measurements for the hallux valgus angle, 1,2 intermetatarsal angle, and dorsiflexion angle were also studied. Results: After the arthrodesis of the first metatarsophalangeal joint, the subjective improvement in pain, function and alignment was graded as excellent in seven (50%) feet, good in seven (50%) feet, and fair or poor in none. The hallux valgus angle and 1,2 intermetatarsal angle were reduced from $44.1{\pm}7.1$ and $15.5{\pm}6.2$ degrees to $13.6{\pm}2.6$ and $10.2{\pm}2.2$ degrees respectively. The dorsiflexion angle was measured in $20.3{\pm}3.7$ degrees after the fusion. The radiological fusion was observed at average 8 weeks after the operation in all cases. The overall complication of the procedure was few, except the delayed wound healing in one. Conclusion: The arthrodesis of the first metatarsophalangeal joint using a lag screw and dorsal mini-plate was regarded as an excellent method of various operative modalities to correct the rheumatoid hallux valgus deformity.

  • PDF

Surgical Outcomes of Intra-articular Fractures of Calcaneus using AO Calcaneal Plate (관절내 종골 골절에 대해 AO 종골 금속판을 이용한 수술적 치료 결과)

  • Kim, Seong-Tek;Youn, Te-Hyun;Park, Jin-Bum;Lee, Jun-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.75-79
    • /
    • 2009
  • Purpose: To evaluate the outcomes of intra-articular calcaneal fractures treated using AO calcaneal plate surgically. Materails and Methods: Total 15 cases of intra-articular calcaneal fracture that treated with open reduction and internal fixation using AO calcaneal plate were evaluated. The patients were followed over a mean period of 19.8 months. The mean age was 41.6 years. By Sanders classification, there were 2 cases of type II, 10 cases of type III, and 3 cases of type IV. We evaluated radiological outcomes by Bohler angle, Gissane angle, calcaneal hight, calcaneal width and clinical outcomes by Creighton-Nebraska health foundation score. Results: All fractures united at a mean duration of 13.3 weeks. Radiologically, the mean preoperative Bohler angle was $8.5^{\circ}$ and restored to $23.3^{\circ}$. The mean preoperative Gissane angle was $118.7^{\circ}$ and restored to $124.2^{\circ}$. The mean preoperative calcaneal hight was 30.8 mm and restored to 38.9 mm. The mean preoperative calcaneal width was 41.3 mm and restored to 35.3 mm. 10 cases had excellent and good clinical outcomes and 5 cases having fair outcome. Conculsion: In our study, open reduction and internal fixation using AO calcaneal plate showed good results with anatomical restoration of articular surface and stable fixation without late collapse.

  • PDF

The Clinical Results of the Proximal Opening Wedge Osteotomy Using a Low Profile Plate in Hallux Valgus: Comparison with Proximal Chevron Osteotomy Fixed with K-wires (무지외반증에서 저상형 금속판 고정을 이용한 근위 개방형 절골술의 임상적 결과: 근위 갈매기형 절골술 후 K-강선 고정술과의 비교)

  • Seo, Eun-Seok;Bang, Tae-Jung;Jeon, Suk-Ha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.4
    • /
    • pp.302-308
    • /
    • 2013
  • Purpose: To present clinical results of proximal first metatarsal opening wedge osteotomy and low profile plate fixation in hallux valgus deformity. Materials and Methods: Thirty-two patients (39 feet) underwent surgery for hallux valgus deformity. Fourteen patients (18 feet; Group A) underwent proximal first metatarsal opening wedge osteotomy fixed with low profile titanium plate ($Arthrex^{(R)}$), and 18 patients (21 feet; Group B) underwent proximal chevron osteotomy with two K-wires. Improvement in hallux valgus angle (HVA), 1, 2 intermetatarsal angle (IMA), range of motion of 1st metatarsophalangeal joint, VAS score, and the length of first metatarsal on weight-bearing radiograph were evaluated preoperatively and at final follow-up. Results: HVA improved from $36.2{\pm}6.6$ degrees to $11.7{\pm}5.1$ degrees, and 1, 2 IMA improved from $15.7{\pm}2.6$ degrees to $7.2{\pm}1.9$ degrees. VAS score improved from $7.2{\pm}1.2$ to $1.4{\pm}0.9$. There were no significant differences clinically and radiologically. Conclusion: Proximal first metatarsal opening wedge osteotomy with stable fixation using low profile plate may be an effective surgical option for correction of hallux valgus deformity.

Design and performance test of a foot for a jointed leg type quadrupedal walking robot (관절형 4족 보행로봇용 발의 설계 및 성능시험)

  • Hong, Ye-Seon;Yi, Su-Yeong;Ryu, Si-Bok;Lee, Jong-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.8
    • /
    • pp.1250-1258
    • /
    • 1997
  • This paper reports on the development of a new foot for a quadrupedal jointed-leg type walking robot. The foot has 2 toes, one at the front and the other at the rear side, for stable landing on uneven ground by point contact. The toes can move up and down independantly, guided by double-wishbone shaped parallel links which enable the lower leg to rotate with respect to a remote center on the ground surface. The motion of each toe is damped by a hydropneumatic shock absorber integrated in the foot in order to absorb the dynamic landing shock. Furthermore, the new foot can reduce the maximum hip joint drive torque by shortening the moment arm length between the hip joint and the landing force vector on the ground. Intensive experiments were carried out in this study by using a one-leg walking model to investigate the soft landing performance of the foot which could be hardly offered by conventional robot feet such as a flat plate with a gimbal type ankle joint. And it was confirmed that the hip joint torque of the leg walking on the flat surface could be reduced remarkably by using the new foot.

Development of a Prototype Force Plate Employing Load Cells (로드셀을 사용한 2 차원 반력측정반)

  • Park, Ji-Hee;Khang, Gon
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.178-180
    • /
    • 1994
  • We developed a prototype force plate equipped with five load cells, a 12-bit analog-to-digital converter and three integrated circuits. The force plate displays the center of foot pressure, the magnitude and two (vertical and anterior-posterior) directions of the ground reaction force on a personal computer monitor. Although the force plate data are valid only for two directions, it can be a preliminary version of a more versatile 3 dimensional force plate in terms of the resolution and reliability.

  • PDF