• 제목/요약/키워드: Foot type

검색결과 541건 처리시간 0.026초

소아마비에서 4절 연쇄 장하지보조기 사례연구 (Case Study of 4-Bar Linkage KAFO in Person With Poliomyelitis)

  • 김장환;권오윤;이충휘;조상현;신헌석;최흥식
    • 한국전문물리치료학회지
    • /
    • 제20권1호
    • /
    • pp.18-27
    • /
    • 2013
  • The purpose of this study was to compare the ring lock type knee-ankle-foot orthosis (KAFO) with newly developed 4-bar linkage KAFO on the gait characteristics of persons with poliomyelitis clinically. This 4-bar linkage is the stance control type KAFO which provide the stability during stance phase and knee flexion during swing phase. Two subjects participated in this study voluntarily. We provided the customized 4-bar linkage KAFO then asked the subjects to walk in level surface and stairs under the two different KAFO conditions. The characteristics of gait in the persons with poliomyelitis were evaluated using a 3D motion analysis system and force plate. Additionally 6 minute walk test for physiological cost index were conducted using pulse oximeter to measure the energy consumption. In the results of this study, the differences of 4-bar linkage KAFO compared with ring lock type KAFO are as follows: (1) Walking speed, stride length, and step length on level increased in subjects, (2) The gait symmetry was improved by generated knee flexion and decreased pelvic external rotation on level and stairs walking, (3) Decreased vertical excursion of center of mass and pelvic elevation during swing phase was decreased on level, (4) Knee extension moment, hip flexion moment, hip and knee internal rotation moment of non-braced limb were decreased on level walking, (5) Walking speed in 6-minute walk test was increased and physiological cost index was decreased. These findings indicate that 4-bar linkage KAFO compared with ring lock type KAFO is effective in enhancing pattern, endurance, and energy consumption in level surface and stairs walking.

제 2형 당뇨병 환자를 위한 포괄적 자기효능증진 자가관리 프로그램 개발 (Development of a Comprehensive Self-Management Program Promoting Self Efficacy for Type 2 Diabetic Patients)

  • 박주영;고일선
    • 기본간호학회지
    • /
    • 제19권1호
    • /
    • pp.74-86
    • /
    • 2012
  • Purpose: The purpose of this study was to develop a comprehensive self-management program promoting self efficacy for Type 2 diabetic patients. Methods: The study was a methodological research design in which previous related research was reviewed to develop the comprehensive self-management program promoting self efficacy using self efficacy theory. Results: Comprehensive self-management programs promoting self efficacy included the whole range of eight self-management domains: diet, exercise, medication, self-testing of blood glucose, complication or foot, stress, time, and general health, and consisted of four sources of self efficacy: enactive mastery experience, vicarious experience, verbal persuasion, and physiological and affective states, as strategies to promote self efficacy. Developmental methods included, in addition to large and small group education, individual education or counseling, and telephone counseling. Conclusion: Further studies are needed in community health centers or hospitals to establish the effects on self-management compliance and glycemic control of the comprehensive self-management program promoting self efficacy.

내장산국립공원내 서식하는 안주애기박쥐(Vespertilio sinensis)의 외부형태 및 채식지 환경특성 (External Morphology and Environment of Foraging Site in Asian parti-coloured Bat Vespertilio sinensis in Naejangsan National Park)

  • 정철운;김태근;김성철;임춘우;한상훈
    • 한국환경과학회지
    • /
    • 제24권2호
    • /
    • pp.261-266
    • /
    • 2015
  • We have analyzed the external morphology and the environment of the foraging site of Vespertilio sinensis. The external morphology was analyzed by twelve parameters and the environment characteristics of the foraging site was analyzed using GIS 10.1 program. The wing membrane was inserted into the ankle of the hind foot and the wing ratio was 1.42, the middle type between broad-short wing type and long-narrow wing type. The fur color was blackish brown but the guard hair color was whitish. The shape of the ear was a rounded triangle and tragus was a fan shape. This study showed that V. sinensis preferred the deciduous forest of the upper forest zone, where human interference was less. We believed that abundance of insects, depending on water system, was closely related to the use of the foraging site. This result showed that the environment characteristics was very similar to the nature preservation zone including Baekyang valley and Keumsun valley in Naejangsan National Park.

Regulation of type-1 protein phosphatase in a model of metabolic arrest

  • Ramnanan, Christopher J.;Storey, Kenneth B.
    • BMB Reports
    • /
    • 제42권12호
    • /
    • pp.817-822
    • /
    • 2009
  • Type-1 phosphatase (PP-1) was assessed in foot muscle (FM) and hepatopancreas (HP) of estivating (EST) Otala lactea. Snail PP-1 displayed several conserved traits, including sensitivity to inhibitors, substrate affinity, and reduction in size to a 39 kDa catalytic subunit (PP-1c). During EST, PP-1 activity in FM and HP crude extracts was reduced, though kinetics and protein levels of purified PP-1c isoforms were not altered. PP-1c protein levels increased and decreased in nuclear and glycogen-associated fractions, respectively, during EST. Gel filtration determined that a 257 kDa low $K_m$ PP-1$\alpha$ complex decreased during estivation whereas a 76 kDa high $K_m$ complex increased in EST. Western blotting confirmed that the 76 kDa protein consisted of PP-1$\alpha$ and nuclear inhibitor of PP-1 (NIPP-1). A suppression of PP-1 activity factors in the overall metabolic rate depression in estivating snails and the mechanism is mediated through altered cellular localization and interaction with binding partners.

타이트 스커트 종류에 따른 동작기능성에 관한 연구 (A Study on Moving Function in Relation to the Length and Silhouette of Tight Skirt)

  • 이혜선;최혜선
    • 한국의류학회지
    • /
    • 제22권1호
    • /
    • pp.18-28
    • /
    • 1998
  • The objective of the study was to observe the difference of moving function of lower-limb in relation to the length 8t silouutte of tight skirt. Four types of tight skirts (2 lengths$\times$2 silhouettes) were made for the experiment. The surface E.M.S in four different locations of leg muscles (Rectos femoris, Semitendinosus, Tibalis anterior, Gastrocnemius) were recorded. The sensory test to decide how to be fatigued after longtime wearing of skirt were examined two times per a day. The fatigue sensory test was scored a Likert-type scale (1= no fatigue, 5=heavy fatigue). Data were analyzed by the repeated ANOVA ann Duncan's multiple range test with use of SAS Package. The main results of this study were as follows: 1. As a result of analysis of E.M.S., in case of walking on the floor there was significant difference in the moving function according to length of skirt and in case of stepping there was significant differnce in three ways (length silhouette, length, silhouette). 2. From the record of walking the step-length, stride-length, step-width were found affected by garments, but foot-angle was not affected. The moving function of slim type was lower than that of semi type and that of ankle-length skirt was lower than that of knee-length skirt. 3. The results of the sensory test agreed with that of E.M.G and Footprints.

  • PDF

2륜구동 전기차량용 회전 제어 장치 개발 (The Development of a Steering Control Apparatus for the Two Wheel Driving Electric Vehicles)

  • 임동균;손민호;최중경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1115-1118
    • /
    • 2015
  • 전기모터 구동 방식의 2륜 전기 차량은 공항, 항만 등에서 경계형 정숙 차량으로 좁은 실내를 이동하는데 많이 사용되고 있다. 이런 2륜형 전기 차량은 밧데리로 구동되며, 전/후진 및 회전 제어에 있어 여러 센서 및 핸들 조작 장치를 이용하는 제어 장치를 사용한다. 본 연구에 있어서는 탑승자가 별도의 손잡이형 회전제어 장치를 사용하지 않고도 두발의 무게 중심 만을 이용하여 회전하는 센서 인터페이싱 전자 제어 장치를 설계한다. 코너링 회전 시 탑승자의 안전성을 고려하는 설계라 할 수 있다.

  • PDF

의료용 모바일 X선 장치의 개발 (Development of Mobile X-ray equipment for medicine)

  • 김태곤;김영표;천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.762-763
    • /
    • 2010
  • 의료에 사용되는 X선 장치는 안정적인 전원이 공급되는 곳에 설치되어 사용되어지는 고정형과 환자가 있는 장소로 이동하여 촬영이 가능한 이동형으로 구분된다. 이동형 X선 장치에 대표적으로 사용되는 모바일 X선 장치는 공간상의 제약을 벗어나 매우 유용하게 사용이 가능하다. 하지만 고전압의 발생이 어려워 X선의 출력이 낮은 주로 손과 발의 촬영에 주로 응용된다. 본 연구에서는 인체의 진단영역에 제한을 가지지 않는 대용량의 모바일 X선 장치를 설계, 제작하여 부하변동에 따른 기기의 동작 특성을 확인하였다.

  • PDF

3D Facial Scanners: How to Make the Right Choice for Orthodontists

  • Young-Soo Seo;Do-Gil Kim;Gye-Hyeong Lee;Kyungmin Clara Lee
    • Journal of Korean Dental Science
    • /
    • 제17권1호
    • /
    • pp.1-13
    • /
    • 2024
  • With the advances of digital scanning technology in dentistry, the interests in facial scanning in orthodontics have increased. There are many different manufacturers of facial scanners marketing to the dental practice. How do you know which one will work best for you? What questions should you be asking? We suggest a clinical guideline which may help you make an informed decision when choosing facial scanners. The characteristics of 7 facial scanners were discussed in this article. Here are some considerations for choosing a facial scanner. *Accuracy: For facial scanners to be of real value, having an appropriate camera resolution is necessary to achieve more accurate facial image representation. For orthodontic application, the scanner must create an accurate representation of an entire face. *Ease of Use: Scanner-related issues that impact their ease of use include type of light; scan type; scan time; file type generated by the scanner; unit size and foot print; and acceptance of scans by third-party providers. *Cost: Most of the expenses associated with facial scanning involve the fixed cost of purchase and maintenance. Other expenses include technical support, warranty costs, transmission fees, and supply costs. This article suggests a clinical guideline to make the right choice for facial scanner in orthodontics.

부인과질환, 월경통과 여성 체형 및 체온의 상관성 연구 (A Study on Women's Body Type and Body Temperature in Relation to Gynecologic Disorders and Dysmenorrhea)

  • 최석영;안지윤;이미주;이진무;장준복;이경섭;이창훈
    • 대한한방부인과학회지
    • /
    • 제25권4호
    • /
    • pp.81-93
    • /
    • 2012
  • Objectives: A women's body type or body temperature is often thought to be associated with gynecologic disorders or dysmenorrhea. The purpose of this study is to analyse the characteristics of body type and body temperature in relation to gynecologic disorders and dysmenorrhea. Methods: We studied 40 patients visiting Kangnam Kyung-hee Medical Center from Jan. 1st, 2010 to March 31st, 2012. Body type and body temperature were compared between Gynecologic disorder group and non-Gynecologic disorder group. Body type and body temperature were compared again between Dysmenorrhea group and non-Dysmenorrhea group. SPSS 18.0 for Windows was used to analyse the data. Results: There was no statistically significance difference in body type and body temperature between Gynecologic disorder group and non-Gynecologic disorder group. Dysmenorrhea group had more developed lower body and greater temperature difference between lower abdomen and foot compared to non-Dysmenorrhea group. Conclusions: The results suggest that women with developed lower body and greater temperature difference between abdomen and lower extremity are more prone to dysmenorrhea.

여대생의 체형별 신체만족도와 의복이미지 연구 (Body Cathexis and Clothing Image of Female Collegians by Somatotype)

  • 이미진;김양원
    • 한국지역사회생활과학회지
    • /
    • 제23권3호
    • /
    • pp.221-231
    • /
    • 2012
  • To find the differences between the real somatotype and the ideal somatotype, WHR(Waist to Hip Ratio), WCR(Waist to Chest Ratio), and body cathexis were analysed by using ANOVA test, Duncan's multiple range test, and $x^2$ test. Fashion image sought by female collegians was surveyed, too. The results were as follows. WHRs in slim, usual, fat body type were 0.75, 0.76, and 0.83 and WCRs were 0.77, 0.81, 0.80. The respondents who considered themselves to be overweight recognized themselves to be fatter than their real weight. They were not satisfied with their bust girth in slim body type, thighs and calves in usual body type, and all parts except for foot length, hand length and arm length in fat body type. 60% of the thin people considered their body hourglass shape, 30.4% of regular people recognized their body triangle type, 43.8% of fat people thought their body was round form. They thought current ideal body size was bigger in height and bust girth and smaller in waist girth and hip girth, and weight than real body size. Also they responded ideal body shape was an hourglass type independent of somatotype. The pursuit of clothing image was that 45.5% of female collegians were fashionable and raffine and 10.4% of female collegians was elegant and graceful. Among the body area, body parts that may have an effect on body image were body length in 13.1% of the respondents, waist girth in 10.7% of the respondents, and hip girth in 10.0% of the respondents.